Blood Test Determines Reduced and Oxidized Glutathione

By LabMedica International staff writers
Posted on 31 Jul 2013
Print article
Image: API 3000 triple-quadrupole mass spectrometer (Photo courtesy of Applied Biosystems).
Image: API 3000 triple-quadrupole mass spectrometer (Photo courtesy of Applied Biosystems).
Diminished levels of glutathione (γ-glutamylcysteinylglycine, GSH) and the ratio of GSH to glutathione disulfide (GSSG) can serve as important indicators of oxidative stress and disease risk.

A simple and sensitive liquid chromatography-tandem mass spectrometry (LC–MS/MS) method for measuring whole blood GSH and GSSG has been developed and can easily be implemented in clinical laboratories.

Scientists at Stanford University School of Medicine (CA, USA) developed an approach that minimizes preanalytical variability through a one-step procedure of deproteinization and derivatization that prevents artifactual oxidation of GSH, and is easily adapted to the clinical setting without requiring excessive constraints on sample handling or storage. The team used anonymous, residual blood samples from 59 healthy individuals, 31 males, and 28 females, with an age range 1 to 87 years, with a mean of 25 years.

Compounds were separated by liquid chromatography using a Hypercarb column (Thermo Scientific; Waltham, MA, USA) at room temperature. The GSH and GSSG ions and fragments were detected using the API 3000 triple-quadrupole mass spectrometer (Perkin-Elmer; Waltham, MA, USA). The final concentrations of GSH and GSSG were expressed in units of μmol/L of whole blood.

The lower limits of detection (LLOD) were 0.4 μM for GSH and 0.1 μM for GSSG and the lower limits of quantitation (LLOQ) were 1.5 μM for GSH and 0.1 μM for GSSG. There was excellent linearity for both GSH and GSSG over the ranges of physiologic normal, with inter- and intra-assay coefficient of variation of 3.1% to 4.3% and accuracy between 95% and 101%. Derivatized samples are stable for at least three years when stored at -80 °C and underivatized samples for at least 24 hours at either 4 °C or room temperature. As a group, the mean concentration ± standard deviation for GSH was 900 ± 140 μM, GSSG 1.17 ± 0.43 μM, and GSH/GSSG ratio was 880 ± 370.

The authors concluded that their LC–MS/MS method minimizes preanalytic variability through a one-step procedure of deproteinization and derivatization, and chromatographic conditions that eliminate ion suppression and increase precision and sensitivity. Additional advantages included the small sample requirement, simple and rapid preanalytical processing, and wide automation possibilities, which makes this method ideal for routine and large-scale clinical testing. The study was published on June 15, 2013, in the Journal of Chromatography B.

Related Links:

Stanford University School of Medicine
Thermo Scientific
Perkin-Elmer


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Molecular Diagnostics

view channel
Image: Ultrasound-based duplex sonography combined with a new genetic testing procedure can identify clonal haematopoiesis (Photo courtesy of 123RF)

New Genetic Testing Procedure Combined With Ultrasound Detects High Cardiovascular Risk

A key interest area in cardiovascular research today is the impact of clonal hematopoiesis on cardiovascular diseases. Clonal hematopoiesis results from mutations in hematopoietic stem cells and may lead... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more