We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Immunological Tests Are Superior for Colon Cancer Screening

By LabMedica International staff writers
Posted on 18 Jul 2013
Print article
Image: OC-Sensor fully automated fecal occult blood analyzer (Photo courtesy of Eiken Chemical).
Image: OC-Sensor fully automated fecal occult blood analyzer (Photo courtesy of Eiken Chemical).
The fecal immunochemical tests (FITs) for hemoglobin offer a number of advantages over traditional guaiac based fecal occult blood tests (gFOBTs).

The major advantage seems to come at the price of higher positivity rates and lower specificity and hence a higher load of work-up colonoscopies, which makes a final judgment of the superiority of either test difficult.

Scientists from the German Cancer Research Center (Heidelberg, Germany) compared three quantitative FITs with a gFOBT among participants of the German screening colonoscopy program. They obtained stool samples and colonoscopy reports from 2,235 participants of screening colonoscopy from 2005 to 2009. Patients willing to participate were given stool collection instructions and devices, including a small container and one test card for a gFOBT (HemOccult, Beckman Coulter; Krefeld, Germany).

The stored stool samples were assayed with two automated, enzyme-linked immunosorbent assay (ELISA) based FITs, RIDASCREEN Haemoglobin, and RIDASCREEN Haemo-/Haptoglobin Complex, (R-Biopharm AG; Darmstadt, Germany). Cut-offs for positivity was 2 μg hemoglobin per gram stool. The stool samples were further analyzed, including a third FIT, OC-SENSOR, (Eiken Chemical; Tokyo, Japan).

The enzyme-based test detected one third of all colon cancer cases, about 9% of advanced precancerous adenomas lesions, and about 5% of early precancerous lesions. In 95 out of 100 participants with negative test results, no tissue abnormalities were found in the subsequent colonoscopy. Despite the already high specificities of the gFOBT for all outcomes, ranging from 95.2% to 95.4%, specificities were even higher for each of the FITs and each outcome. With estimates between 96.8% and 97.8%, specificities with respect to the detection of any cancer or any advanced neoplasm were very high for all three FITs.

Hermann Brenner, MD, MPH, a professor of clinical epidemiology, and senior author of the study said, “For the first time we have shown by direct comparison that the diagnostic performance of immunological stool tests is significantly higher than that of the enzymatic test at the same rate of positive results. Tests for occult blood in the stool will continue to be an important part of colon cancer screening. We therefore recommend including immunological tests in cancer screening programs in Germany. Many more people would thus benefit by obtaining a life-saving clue pointing to a hidden case of cancer.” The study was published on May 22, 2013, in the European Journal of Cancer.

Related Links:

Beckman Coulter
R-Biopharm
Eiken Chemical



Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A massive study has identified new biomarkers for renal cancer subtypes, improving diagnosis and treatment (Photo courtesy of Jessica Johnson)

Novel Biomarkers to Improve Diagnosis of Renal Cell Carcinoma Subtypes

Renal cell carcinomas (RCCs) are notably diverse, encompassing over 20 distinct subtypes and generally categorized into clear cell and non-clear cell types; around 20% of all RCCs fall into the non-clear... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more