We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

CSF Immunoassays Aid Diagnosis of Early Alzheimer’s Disease

By LabMedica International staff writers
Posted on 21 Dec 2022
Image: The Cobas Е 801 Analyzer analytical unit is a high throughput immunochemistry module that performs a broad range of heterogeneous immunoassay tests (Photo courtesy of Dialogue Diagnostics LLC)
Image: The Cobas Е 801 Analyzer analytical unit is a high throughput immunochemistry module that performs a broad range of heterogeneous immunoassay tests (Photo courtesy of Dialogue Diagnostics LLC)

The pathological processes underlying Alzheimer’s disease (AD) begin many years before clinical presentation. Ongoing drug discovery efforts in AD focus on developing disease-modifying treatments aiming to delay onset or progression of dementia and must be initiated early in the disease process.

Cerebrospinal fluid (CSF) biomarkers beta-amyloid (1–42) (Aβ42), phosphorylated tau 181P (pTau181), and total tau (tTau) accurately identify early AD by detecting pathophysiological changes underlying the disease. CSF biomarkers should be measured robustly to aid diagnosis of AD; however, there are difficulties with CSF measurement, including pre-analytical and analytical factors.

Clinical Scientists at the Skåne University Hospital (Malmö, Sweden) and their colleagues assessed the analytical performance of second-generation (Gen II) Elecsys CSF immunoassays (Roche Diagnostics International Ltd, Penzberg, Germany), and adjusted existing cut-offs, to evaluate their potential utility in clinical routine. Samples were analyzed using Elecsys CSF Aβ42, pTau181, and tTau Gen II immunoassays on the Roche Diagnostics’ cobas e 801 analyzer. CSF samples (n>100) were analyzed using a single reagent lot with the three immunoassays on cobas e 801, e 402, e 601, and e 411 analyzers.

The investigators reported that the Gen II immunoassays demonstrated good analytical performance, including repeatability, intermediate precision, lot-to-lot agreement, and platform agreement. Aβ42 Gen I/Gen II immunoassay measurements were strongly correlated. Aβ42 Gen II immunoassay cut-offs were adjusted to 1,030 and 800 ng/L, and pTau181/Aβ42 ratio cut-offs to 0.023 and 0.029, for Gen II and I protocols, respectively. No observations were below the lower limit of the measuring range; above the upper limit, there were none from the AD cohort, and 2.6 and 6.8% from the mild cognitive impairment (MCI) and cognitively normal cohorts, respectively.

The authors concluded that the Elecsys CSF Gen II immunoassays demonstrated good analytical performance on extended cobas e platforms, including precision, lot-to-lot comparisons, and platform agreement, supporting their use in clinical routine to aid diagnosis of early AD. Elecsys CSF Gen II immunoassays provide additional benefits over the Gen I immunoassays, without compromising technical performance. Good technical performance of the immunoassays, plus reduced pre-analytical variability (a result of the new protocol), may provide a solution towards unified biomarker testing and timely diagnosis for patients with early AD. The study was published on October 24, 2022 in the journal Clinical Chemistry And Laboratory Medicine.

Related Links:
Skåne University Hospital
Roche Diagnostics International

Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
Nucleic Acid Extractor System
NEOS-96 XT
Creatinine/eGFR Meter
StatSensor® Creatinine/eGFR Meter
Hematology Consumables
Bioblood Devices

Channels

Clinical Chemistry

view channel
Image: Nian Sun has spent years perfecting a device that he believes could change the way diseases are detected. (Photo courtesy of Alyssa Stone/Northeastern University)

Rapid Breath Sensor Detects SARS-CoV-2 from Exhaled Air

Nasal swabs and polymerase chain reaction (PCR) testing have been central to identifying SARS-CoV-2, but they can be uncomfortable, slow, and logistically complex when samples require transport.... Read more

Molecular Diagnostics

view channel
Image: The duet mosaic family comprises duet +modC mosaic and duet 6-base mosaic, two cfDNA-optimized multiomic sequencing workflows for liquid biopsy and translational research. (Photo courtesy of bimodal)

New Liquid Biopsy Workflow Maximizes Tumor Signals from Limited Blood Samples

Liquid biopsy seeks to detect tumor-derived signals from small blood samples, but circulating cell-free DNA is scarce and heterogeneous, limiting sensitivity. Combining complementary signals such as methylation,... Read more