We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Elecsys Androstenedione Immunoassay Evaluated and Compared

By LabMedica International staff writers
Posted on 20 May 2022
Image: The new Elecsys Androstenedione assay has been compared and evaluated (Photo courtesy of Blood Tests London)
Image: The new Elecsys Androstenedione assay has been compared and evaluated (Photo courtesy of Blood Tests London)

Androstenedione (ASD) is a biomarker used in the diagnostic workup of hyperandrogenism, congenital adrenal hyperplasia, premature adrenarche, and polycystic ovary syndrome (PCOS). Androstenedione is the precursor of testosterone and estrone and is produced in the gonads and adrenal glands.

Along with other sex hormones, ASD is essential for the onset and development of sexual differentiation in males and females. ASD measurement in serum or plasma is used to assess adrenal and gonadal function and steroid hormone biosynthesis deficiency. A new ASD competitive electrochemiluminescence immunoassay has been evaluated.

Medical Laboratory Scientists at the Cleveland Clinic (Cleveland, OH, USA) evaluated the linearity/analytical measuring range (AMR), precision, and accuracy of the Elecsys ASD assay on the cobas e601 analyzer (Roche Diagnostics, Indianapolis, IN, USA). For comparison, the Immulite ASD was performed using the Immulite 2000 (Siemens Medical Solutions USA, Inc. Malvern, PA, USA). Specimens were sent to a reference laboratory for analysis by LC-MS/MS. The scientists used 40 specimens (33 sera and seven plasma samples) for the method comparison studies The Elecsys ASD assay is an 18-minute competitive electrochemiluminescence immunoassay that utilizes ASD-specific biotinylated monoclonal antibodies and ruthenium complex-conjugated ASD for ASD assessment.

The investigators reported that the Elecsys ASD assay had a linear response across the AMR. The intra- and inter-assay coefficients of variation at various concentrations were ≤4.5%. The Elecsys ASD assay had a mean difference of −0.04 ng/mL (−1.7%) with the LC-MS/MS assay, whereas the Immulite assay had a mean difference of 1.17 ng/mL (66%) and −1.22 ng/mL (−38%) compared to the LC-MS/MS and Elecsys ASD assays, respectively. The Roche recommended RIs for healthy men (0.280–1.52 ng/mL) and postmenopausal women (0.187–1.07 ng/mL) were successfully verified. The RIs for children were adopted from published data. For pre-menopausal women, a RI of <1.60 ng/mL was established. The ASD concentrations in women with and without PCOS overlapped.

The authors concluded that the Elecsys ASD assay has excellent precision, specificity, and accuracy. It offers many advantages over the Immulite ASD assay and is a suitable alternative for ASD measurement in clinical laboratories. However, the assay should be thoroughly validated before its use for clinical testing and reference intervals established for the patient population, as needed. The Elecsys ASD assay has superior comparability to the LC-MS/MS assay than the Immulite assay. The study was published on May 10, 2022 in the journal Practical Laboratory Medicine.

Related Links:
Cleveland Clinic 
Roche Diagnostics 
Siemens Medical Solutions USA 

Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
Aspiration System
VACUSAFE
Gold Member
Fully-auto Specific Protein (Nephelometry) Analyzer
PA240
Japanese Encephalitis Test
Japanese Encephalitis Virus Real Time PCR Kit

Channels

Clinical Chemistry

view channel
Image: Tracking blood test trends alongside unexplained weight loss may help identify patients at increased cancer risk and support earlier investigation (Image Credit: 123RF)

Blood Test Patterns Improve Cancer Risk Assessment in Primary Care

Unexplained weight loss is a common but nonspecific presentation in primary care that can precede several types of cancer, making referral decisions difficult. Routine blood tests may produce borderline... Read more

Molecular Diagnostics

view channel
Image: NTM are about 200 environmental bacteria found in soil and water that can cause chronic, tuberculosis-like lung infections but are distinct from the Mycobacterium tuberculosis complex (Image Credit: Adobe Stock)

Rapid CRISPR Test Identifies Nontuberculous Mycobacteria Species from Respiratory Samples

Chronic lung infections caused by nontuberculous mycobacteria (NTM) are increasingly recognized but frequently mistaken for tuberculosis, complicating diagnosis and care. These infections may affect as... Read more

Immunology

view channel
Image: Although many people harbor latent Epstein-Barr virus (EBV), growing evidence has linked the virus to MS pathobiology (Image Credit: Adobe Stock)

Blood EBV Activity Biomarkers May Predict Multiple Sclerosis Relapse Months Ahead

Predicting relapse in multiple sclerosis (MS) remains difficult, limiting opportunities for timely intervention and monitoring. Although many people harbor latent Epstein-Barr virus (EBV), growing evidence... Read more

Microbiology

view channel
Image: Graphical Abstract (Jose A. Céspedes, Maria I. Montañez, Isabel M. Jiménez, et al. Magnetic nanoparticles enable clinically relevant in vitro diagnosis of beta-lactam allergy. Materials Today Bio (2026). DOI: 10.1016/j.mtbio.2026.103356)

Magnetic Nanoparticles Enable More Sensitive Beta-Lactam Allergy Testing

Penicillin allergy labels are common in clinical practice, yet many are incorrect and can lead to suboptimal antibiotic choices. Although 8%–25% of people report a penicillin allergy, only 1%–10% are truly... Read more

Pathology

view channel
Image Credit: Adobe Stock

Machine Learning Cytology Tool Improves Cancer Cell Identification

Cytological screening remains central to early cancer detection, but its accuracy depends heavily on expert interpretation of stained cells. Under conventional microscopy, malignant and reactive cells... Read more

Industry

view channel
Image: The acquisition adds Convergent Genomics’ UroAmp platform and proprietary urinary tumor DNA technology to Veracyte’s portfolio (Photo courtesy of Convergent Genomics)

Veracyte Acquisition Expands Urine-Based Bladder Cancer Monitoring Capabilities

Veracyte, Inc. has acquired Convergent Genomics, expanding its urology diagnostics offerings with the company’s UroAmp platform and proprietary urinary tumor DNA (utDNA) technology. UroAmp has been clinically... Read more