LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Menstrual Blood Testing With Capture Sequencing Detects High-Risk Human Papillomavirus

By LabMedica International staff writers
Posted on 04 Jan 2022
Print article
Image: The 21 HPV GenoArray Diagnostic Kit for the rapid and accurate HPV genotyping macro array for 21 human papillomavirus identification (Photo courtesy of Hybribio Ltd)
Image: The 21 HPV GenoArray Diagnostic Kit for the rapid and accurate HPV genotyping macro array for 21 human papillomavirus identification (Photo courtesy of Hybribio Ltd)
Persistent infection of high-risk human papillomavirus (hrHPV) is associated with various HPV-related pre-cancers and cancers. In recent years, HPV testing has gradually become the primary method for cervical cancer screening.

Self-sampling HPV testing is a proposed alternative cervical cancer screening for avoiding stigma and improving participation. Most existing self-sampling HPV studies were based on various sampling brushes inserted into the vagina, and patients may experience discomfort during sampling. Compared with these methods, menstrual blood (MB) collection is associated with less stigma and pain.

Gynecologists at the Sun Yat-sen University (Guangzhou, China) and their colleagues recruited women who were premenopausal and had tested positive for hrHPV in the Central Hospital of Wuhan (Wuhan, China), from September 1, 2020, to April 1, 2021. Cervical smears were collected from recruited patients by an experienced gynecologist. Self-provided commercial sanitary pads were used to collect MB from enrolled patients. A total of 120 enrolled women with hrHPV (mean [SD; range] age, 33.9 [6.9; 20.0 -52.0] years) provided 137 sanitary pads.

A commercial Tiangen dried blood spot DNA extraction kit (Tiangen Biotech, Beijing, China) was used to extract MB DNA from sanitary pads. The concentration of DNA was confirmed using the Qubit 4.0 fluorometer and Qubit dsDNA high-sensitivity (HS) assay kit (Thermo Fisher Scientific, Waltham, MA, USA), and the purity of DNA was determined by Thermo Fisher Scientific’s NanoDrop One spectrophotometer. Extracted MB DNA was stored at −20 °C. Sequencing was performed using a NovaSeq PE150 (Illumina, San Diego, CA, USA). The 21 HPV GenoArray (GA) test (Hybribio Ltd., Hong Kong, China) was used for genotyping.

The investigators reported that the overall concordance rate of MB hrHPV capture sequencing and cervical HPV testing was 92.7, with a κ value of 0.763. Among 24 samples with incomplete concordance or discordant results, 11 samples with additional hrHPV genotypes (45.8%), five true-negative samples (20.8%), and the correct hrHPV genotypes of two samples (8.3%) were correctly identified by MB hrHPV capture sequencing. MB hrHPV detection of hrHPV was equivalent on different menstrual cycle days (MCDs), with an MB hrHPV–positive rate of 27/28 patients (96.4%) for MCD 1, 52/57 patients (91.2%) for MCD 2, 27/28 patients for MCD 3, 4/4 of patients (100%) for MCD 4, and 3/3 patients (100%) for MCD 5. The sensitivity of the MB hrHPV capture sequencing was 97.7%.

The authors concluded that MB hrHPV capture sequencing is a feasible and accurate self-collected approach for cervical cancer screening. This study found that this method is associated with superior performance in identification of HPV genotypes and true-negative events compared with cervical HPV testing. The study was published on December 23, 2021 in the journal JAMA Network Open.

Related Links:
Sun Yat-sen University
Central Hospital of Wuhan
Tiangen Biotech
Thermo Fisher Scientific
Illumina
Hybribio Ltd


Gold Member
Troponin T QC
Troponin T Quality Control
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Centromere B Assay
Centromere B Test
New
Binocular Laboratory LED Illuminated Microscope
HumaScope Classic LED

Print article

Channels

Clinical Chemistry

view channel
Image: The tiny clay-based materials can be customized for a range of medical applications (Photo courtesy of Angira Roy and Sam O’Keefe)

‘Brilliantly Luminous’ Nanoscale Chemical Tool to Improve Disease Detection

Thousands of commercially available glowing molecules known as fluorophores are commonly used in medical imaging, disease detection, biomarker tagging, and chemical analysis. They are also integral in... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: The HIV-1 self-testing chip will be capable of selectively detecting HIV in whole blood samples (Photo courtesy of Shutterstock)

Disposable Microchip Technology Could Selectively Detect HIV in Whole Blood Samples

As of the end of 2023, approximately 40 million people globally were living with HIV, and around 630,000 individuals died from AIDS-related illnesses that same year. Despite a substantial decline in deaths... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Sekisui Diagnostics UK Ltd.