We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Direct Oral Anticoagulants Determined by RDT in Urine Samples

By LabMedica International staff writers
Posted on 10 Feb 2020
Print article
Image: The DOAC dipstick is a diagnostic urine test strip, which is intended for qualitative detection of the absence or presence of direct oral anticoagulants (DOACs: Dabigatran, Apixaban, Edoxaban and Rivaroxaban) in human urine by visual identification of colors (Photo courtesy of DOASENSE GmbH).
Image: The DOAC dipstick is a diagnostic urine test strip, which is intended for qualitative detection of the absence or presence of direct oral anticoagulants (DOACs: Dabigatran, Apixaban, Edoxaban and Rivaroxaban) in human urine by visual identification of colors (Photo courtesy of DOASENSE GmbH).
The rapid determination of the presence of direct oral anticoagulants (DOACs) in a patient remains a major challenge in emergency medicine and for rapid medical treatment decisions. All DOACs are excreted into urine.

Emergency situations with a need for point-of-care testing for the presence or absence of DOACs include emergent or urgent major surgical interventions, clinically relevant bleeding, or thrombotic episodes with known or unknown anticoagulant therapy, as well as the evaluation of unconscious patients or those unable to inform clinicians about their anticoagulant therapy.

An international team of scientists led by the Ruprecht Karls University of Heidelberg (Heidelberg, Germany) carried out a prospective, open-label, controlled, nonrandomized, multicenter study in Germany on subjects treated with a DXI (apixaban, edoxaban, and rivaroxaban) or the DTI dabigatran were included. The subjects were recruited from 18 outpatient care units specialized in oral anticoagulation.

Urine samples (4 mL) were transferred into polyethylene terephthalate tubes (V-Monovette Urine Z 4mL, Sarstedt AG, Nümbrecht, Germany) using plastic syringes. The DOAC Dipstick test (DOASENSE GmbH, Heidelberg, Germany) was performed on the urine sample at the time of collection by site personnel. Next, barcodes were attached to the duplicate samples and recorded in the case report form. The samples were frozen immediately at –25 °C, transferred without interrupting the cold chain to a central laboratory for LC-MS/MS analysis. The chromatography system consisted of an ACQUITY H-Class UPLC System connected to an Autosampler, quaternary HPLC-Pump, Xevo TQ-S mass spectrometry detector, and a CSH C18 Column (Waters GmbH, Eschborn, Germany).

Nine hundred and fourteen subjects were included and 880 were evaluated per protocol (451 factor Xa inhibitors apixaban, edoxaban, and rivaroxaban, 429 thrombin inhibitor dabigatran) at 18 centers. The sensitivity, specificity, accuracy, and predictive values and agreement between methods for determination of factor Xa inhibitors were at least noninferior to 95% with a 0.5% margin and of thrombin inhibitor superior to 97.5%. These results were compared with LC-MS/MS results in the intention-to-analyze cohort. The receiver operating curve showed c-values of 0.989 (factor Xa inhibitors) and 0.995 (thrombin inhibitor). Visual evaluation of the factor Xa and thrombin inhibitor pads was not different between centers.

The authors concluded that the present study shows that DOAC Dipstick test sensitively and specifically determines the presence of both Xa and IIa inhibitors in urine samples, if compared with the gold standard of LC-MS/MS. The evaluation of the DOAC Dipstick test in emergency medicine and other patient groups is ongoing. The study was published in the January 2020 issue of the journal Thrombosis and Haemostasis.

Related Links:
Ruprecht Karls University of Heidelberg
Sarstedt AG
DOASENSE GmbH
Waters GmbH


Gold Member
Pharmacogenetics Panel
VeriDose Core Panel v2.0
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Unstirred Waterbath
HumAqua 5
New
PSA Test
Humasis PSA Card

Print article

Channels

Clinical Chemistry

view channel
Image: Professor Nicole Strittmatter (left) and first author Wei Chen stand in front of the mass spectrometer with a tissue sample (Photo courtesy of Robert Reich/TUM)

Mass Spectrometry Detects Bacteria Without Time-Consuming Isolation and Multiplication

Speed and accuracy are essential when diagnosing diseases. Traditionally, diagnosing bacterial infections involves the labor-intensive process of isolating pathogens and cultivating bacterial cultures,... Read more

Molecular Diagnostics

view channel
Image: Macrophages infected with mycobacterium tuberculosis (Photo courtesy of MIT)

New Molecular Label to Help Develop Simpler and Faster Tuberculosis Tests

Tuberculosis (TB), the deadliest infectious disease globally, is responsible for infecting an estimated 10 million people each year and causing over 1 million deaths annually. While chest X-rays and molecular... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Ziyang Wang and Shengxi Huang have developed a tool that enables precise insights into viral proteins and brain disease markers (Photo courtesy of Jeff Fitlow/Rice University)

Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses

Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more