Automated Chemiluminescent Assays Evaluated for Heparin-Induced Antibodies

By LabMedica International staff writers
Posted on 30 Aug 2012
Two recently introduced automated chemiluminescent assays for the detection of antibodies have been evaluated in the diagnosis of heparin-induced thrombocytopenia.

The performance of the two assays was compared with enzyme linked immunosorbent assays (ELISA) heparin-induced antibodies (HIA) tests for immunoglobulins IgG and IgAM.

Scientists at Ghent University Hospital (Belgium) collected citrated plasmas from 87 patients with clinical suspicion of heparin-induced thrombocytopenia (HIT) were analyzed with all four assays and with a functional confirmation assay. The Zymutest HIA IgG and HIA IgGAM assays (Aniara; West Chester, OH, USA) are micro-ELISAs, that take over two hours to perform, were used as the standard reference.

The fully automated quantitative chemiluminescent immunoassays, the HemosIL AcuStar HIT-IgG (Platelet Factor 4-Heparin, PF4-H), specific for IgG anti-PF4/H antibodies, and the HemosIL AcuStar HIT-Ab (PF4-H), detecting IgG, IgM and IgA anti-PF4/H antibodies are products of Instrumentation Laboratory (Bedford, MA, USA). They provide enhanced detection of HIT antibodies in specialty and hospital hemostasis laboratories. Unlike existing manual processes, the ready-to-use, cartridge-based assays offer results in approximately 30 minutes.

The sensitivities of all assays were 100%. The Acustar HIT-IgG assay showed 85% specificity compared to the 73% for the HIT-Ab assay using the manufacturer’s cutoffs. Specificities of all assays, except for the AcuStar HIT-IgG, could be significantly improved when altering the cutoff. Titers were significantly higher for the HIT-Ab assay compared with the HIT-IgG assay. This was also the case for the patients with confirmed HIT indicating that the cutoff of 1.0 Optical Density (OD) for both AcuStar assays, as proposed by the manufacturer, can be adapted for the AcuStar Hit-Ab assay resulting in an increased specificity.

Chemiluminescent technology provides analytical excellence through an expansive working range for high sensitivity and precision allowing clinicians to make timely, well-informed therapeutic decisions. In addition, the Acustar HIT precalibrated reagent cartridges offer significant time- and cost- efficiencies. The study was published in the August 2012 edition of the International Journal of Laboratory Hematology.

Related Links:

Ghent University Hospital
Aniara
Instrumentation Laboratory


Gold Member
Hybrid Pipette
SWITCH
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Automated Chemiluminescence Immunoassay Analyzer
MS-i3080
New
Gold Member
Clinical Drug Testing Panel
DOA Urine MultiPlex

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more