Automated Chemiluminescent Assays Evaluated for Heparin-Induced Antibodies

By LabMedica International staff writers
Posted on 30 Aug 2012
Print article
Two recently introduced automated chemiluminescent assays for the detection of antibodies have been evaluated in the diagnosis of heparin-induced thrombocytopenia.

The performance of the two assays was compared with enzyme linked immunosorbent assays (ELISA) heparin-induced antibodies (HIA) tests for immunoglobulins IgG and IgAM.

Scientists at Ghent University Hospital (Belgium) collected citrated plasmas from 87 patients with clinical suspicion of heparin-induced thrombocytopenia (HIT) were analyzed with all four assays and with a functional confirmation assay. The Zymutest HIA IgG and HIA IgGAM assays (Aniara; West Chester, OH, USA) are micro-ELISAs, that take over two hours to perform, were used as the standard reference.

The fully automated quantitative chemiluminescent immunoassays, the HemosIL AcuStar HIT-IgG (Platelet Factor 4-Heparin, PF4-H), specific for IgG anti-PF4/H antibodies, and the HemosIL AcuStar HIT-Ab (PF4-H), detecting IgG, IgM and IgA anti-PF4/H antibodies are products of Instrumentation Laboratory (Bedford, MA, USA). They provide enhanced detection of HIT antibodies in specialty and hospital hemostasis laboratories. Unlike existing manual processes, the ready-to-use, cartridge-based assays offer results in approximately 30 minutes.

The sensitivities of all assays were 100%. The Acustar HIT-IgG assay showed 85% specificity compared to the 73% for the HIT-Ab assay using the manufacturer’s cutoffs. Specificities of all assays, except for the AcuStar HIT-IgG, could be significantly improved when altering the cutoff. Titers were significantly higher for the HIT-Ab assay compared with the HIT-IgG assay. This was also the case for the patients with confirmed HIT indicating that the cutoff of 1.0 Optical Density (OD) for both AcuStar assays, as proposed by the manufacturer, can be adapted for the AcuStar Hit-Ab assay resulting in an increased specificity.

Chemiluminescent technology provides analytical excellence through an expansive working range for high sensitivity and precision allowing clinicians to make timely, well-informed therapeutic decisions. In addition, the Acustar HIT precalibrated reagent cartridges offer significant time- and cost- efficiencies. The study was published in the August 2012 edition of the International Journal of Laboratory Hematology.

Related Links:

Ghent University Hospital
Aniara
Instrumentation Laboratory


Gold Member
Veterinary Hematology Analyzer
Exigo H400
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Troponin I Test
Quidel Triage Troponin I Test
New
Community-Acquired Pneumonia Test
RIDA UNITY CAP Bac

Print article

Channels

Clinical Chemistry

view channel
Image: The tiny clay-based materials can be customized for a range of medical applications (Photo courtesy of Angira Roy and Sam O’Keefe)

‘Brilliantly Luminous’ Nanoscale Chemical Tool to Improve Disease Detection

Thousands of commercially available glowing molecules known as fluorophores are commonly used in medical imaging, disease detection, biomarker tagging, and chemical analysis. They are also integral in... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Microbiology

view channel
Image: The lab-in-tube assay could improve TB diagnoses in rural or resource-limited areas (Photo courtesy of Kenny Lass/Tulane University)

Handheld Device Delivers Low-Cost TB Results in Less Than One Hour

Tuberculosis (TB) remains the deadliest infectious disease globally, affecting an estimated 10 million people annually. In 2021, about 4.2 million TB cases went undiagnosed or unreported, mainly due to... Read more

Technology

view channel
Image: The HIV-1 self-testing chip will be capable of selectively detecting HIV in whole blood samples (Photo courtesy of Shutterstock)

Disposable Microchip Technology Could Selectively Detect HIV in Whole Blood Samples

As of the end of 2023, approximately 40 million people globally were living with HIV, and around 630,000 individuals died from AIDS-related illnesses that same year. Despite a substantial decline in deaths... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Sekisui Diagnostics UK Ltd.