LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

SARS-Cov-2 RNA Detected in FFPE Tissue by Droplet Digital PCR

By LabMedica International staff writers
Posted on 22 Jun 2022
Print article
Image: SARS-CoV-2 ddPCR Kit is a partition-based endpoint RT-PCR test for the qualitative detection of nucleic acids from SARS-CoV-2 (Photo courtesy of Thermo Fisher Scientific)
Image: SARS-CoV-2 ddPCR Kit is a partition-based endpoint RT-PCR test for the qualitative detection of nucleic acids from SARS-CoV-2 (Photo courtesy of Thermo Fisher Scientific)

SARS-CoV-2 infection can result in diverse, multiorgan pathology, the most significant being in the lungs, heart, kidney, central nervous system, liver, lymph nodes, bone marrow, vasculature, intestine, and placenta.

SARS-CoV-2 infection is usually identified by the detection of viral RNA using reverse transcriptase polymerase chain reaction (RT-qPCR) on nasopharyngeal or oropharyngeal swabs. Patients with current or previous SARS-CoV-2 infection who present with “unexplained” acute or acute on chronic respiratory failure or other organ-specific manifestations may undergo tissue biopsy.

A team of diagnosticians from the Mayo Clinic (Rochester, MN, USA) developed and validated using droplet digital PCR (ddPCR a qualitative test for detection of SARS-CoV-2 in formalin-fixed paraffin-embedded (FFPE) tissues. Thirty-seven tissue samples from 35 autopsy cases (20 positive, 15 negative), a cell block from a cell line infected with SARS-CoV-2, and a cell block from a cell line infected with influenza virus were utilized in a study for accuracy, precision, stability, linearity, and specificity studies.

Total RNA, including viral RNA, was extracted from unstained FFPE tissue scrolls cut at 10 µm by either RNeasy DSP FFPE Kit or miRNeasy FFPE Kit (Qiagen, Hilden, Germany). The RNA was quantified, ranging from 12 to 800 ng/μL, and stored at −80 °C. The assay was performed using the Bio-Rad SARS-CoV-2 ddPCR Test (Bio-Rad Laboratories, Hercules, CA, USA). RNA samples were run both neat and at a 1:100 dilution. After the reaction was partitioned into droplets using the Bio-Rad AutoDG instrument, SARS-CoV-2 nucleocapsid (N1 and N2) target sequences, along with human ribonuclease P/MRP subunit 30 (RPP30) target as a control, were amplified using the Applied Biosystems’ Veriti thermocyclers (Thermo Fisher Scientific, Inc., Waltham, MA, USA).

The scientists reported that SARS-CoV-2 was detected in all 21 known positive samples and none of the 16 negative samples. As few as approximately five viral copies were reliably detected. Since January 2021, many tissue types have been clinically tested. Of the 195 clinical specimens, the positivity rate was 35% with placenta and fetal tissue showing the highest percentage of positive cases. Both intra- and inter-assay measurements were 100% concordant in qualitative positive or negative calls among all replicates for each sample. No amplification of either of the nucleocapsid targets was detected (i.e., 0 droplet count for both N1 and N2) for any of the non-SARS-CoV-2 viruses tested.

The authors concluded that that ddPCR provides both accuracy and sensitivity in detecting patients with low viral load. SARS-CoV-2 ddPCR testing will also aid in understanding atypical presentations of COVID-19, including in patients who present with “unexplained” symptoms or potential long-term sequelae. The study was published on June 15, 2022 in the journal Clinica Chimica Acta.

Related Links:
Mayo Clinic 
Bio-Rad Laboratories 
Thermo Fisher Scientific 
Qiagen

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more