Novel Automated Procalcitonin Immunoassay Compared with Four Different Assays

By LabMedica International staff writers
Posted on 05 May 2022
Print article
Image: The Abbott ARCHITECT B•R•A•H•M•S PCT Test for the quantitative determination of PCT (Procalcitonin) in human serum and plasma on the automated ARCHITECT analyzer (Photo courtesy of Fisher Scientific)
Image: The Abbott ARCHITECT B•R•A•H•M•S PCT Test for the quantitative determination of PCT (Procalcitonin) in human serum and plasma on the automated ARCHITECT analyzer (Photo courtesy of Fisher Scientific)

Procalcitonin (PCT) is an important biomarker of sepsis and respiratory infections. An increase in PCT expression in parenchymal tissue can typically be observed in severe bacterial, but not or significantly less, respectively, in viral infections; thus, measurement of plasma PCT concentrations is an important diagnostic tool for clinicians to distinguish between infections from a bacterial versus viral origin.

In addition, plasma PCT measurements are frequently used for antibiotic therapy monitoring which leads to a more efficient use of antibiotic drugs; this, in turn, has beneficial economic effects and reduces the generation of multi-resistant pathogens. Various automated immunoassays for measuring PCT in patient plasma are available in medical laboratories. However, due to a lack of international reference material for PCT, the assays are not always comparable.

Clinical Chemists at the University Medical Center Göttingen (Göttingen, Germany) randomly collected 120 plasma samples from clinical routine laboratory analysis. Parallel PCT measurements of all samples were carried out using five different automated assays on a total of six analyzers: ARCHITECT BRAHMS PCT on the Architect i2000SR (Abbott Diagnostics, Lake Forest, IL, USA), a two-step chemiluminescence microparticle immunoassay (CMIA) using acridinium-labeled conjugates; Abbott Diagnostics’ ALINITY i BRAHMS PCT on the Alinity i, also a CMIA.

DIASYS PCT FS (DiaSys Diagnostic Systems, Holzheim, Germany), a particle-enhanced turbidimetric immunoassay (PETIA) on the Abbott Diagnostics’ Architect c16000 and Alinity c; Elecsys BRAHMS PCT on the Cobas e411 (Roche Diagnostics, Mannheim, Germany), an electro-chemiluminescence immunoassay (ECLIA) in association with a ruthenium complex-conjugated antibody; LIAISON BRAHMS PCT II GEN on the Liaison XL (DiaSorin, Saluggia, Italy), a sandwich chemiluminescence immunoassay using an isoluminol antibody conjugate.

The investigators reported that the DiaSys assay showed clear differences as compared to the BRAHMS-associated assays when measured on Architect c: i.e. 58% positive mean bias versus Architect i, 67% versus Cobas and 23% versus Liaison. As a result, additional 19% the patients would have a suspected bacterial infection, when using PCT values from the DiaSys assay and commonly accepted decision limits. A crosscheck of the DiaSys calibrator on the BRAHMS-associated systems showed a low recovery of the calibrator material (approximately 50%).

The authors concluded overall, their study showed significant differences between the DiaSys and BRAHMS-associated assays. This could be attributed to a potential DiaSys calibrator problem. This highlights the need for an international reference material for harmonization of the PCT assays. The study was published on April 15,2022 in the journal Practical Laboratory Medicine.

Related Links:
University Medical Center Göttingen 
Abbott Diagnostics 
DiaSys Diagnostic Systems 
Roche Diagnostics 
DiaSorin 

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more