LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

CCN1 Analyzed as a Biomarker for Breast Cancer Detection

By LabMedica International staff writers
Posted on 14 Sep 2021
Print article
Image: The NanoQuant infinite M200 pro reader is an easy-to-use multimode plate reader family (Photo courtesy of Neotec Scientific Instrumentation)
Image: The NanoQuant infinite M200 pro reader is an easy-to-use multimode plate reader family (Photo courtesy of Neotec Scientific Instrumentation)
Breast cancer is the most frequent malignancy in women with 1.7 million new cases and over 500,000 deaths worldwide in 2016. Early detection of cancer is believed to be crucial in reducing cancer death. Despite recent progress in liquid biopsy technologies, early blood-based detection of breast cancer is still a challenge.

Liquid biopsy includes, besides circulating tumor cells, subcellular components like DNA, RNA, and/or proteins that are released by tumor cell deposits into the blood. In particular, circulating cell-free DNA has received great attention. The combination of circulating tumor DNA with circulating tumor-associated proteins has opened a new avenue for cancer screening.

A large team of Medical Scientists at the University Medical Centre Hamburg-Eppendorf (Hamburg, Germany) and their colleagues analyzed secretion of the protein cellular communication network factor 1 (CCN1, formerly cysteine-rich angiogenic inducer 61) in breast cancer cell lines by an enzyme-linked immunosorbent assay (ELISA). Soluble CCN1 in the plasma of 544 patients with breast cancer and 427 healthy controls was analyzed by ELISA.

Samples from patients with benign breast diseases and from 127 patients with acute heart diseases were investigated as additional non-cancer controls. The CCN1 ELISA was performed using fresh blood plasma or archived sample and diluted in Dulbecco’s Modified Eagle Medium with 10% fetal calf serum. The detection was done using the NanoQuant infinite M200 pro reader (Tecan, Männedorf, Switzerland). Samples with a CCN1 concentration equal to or higher than the lower limit of detection were considered as positive in this work.

The investigators reported that CCN1 was frequently secreted by breast cancer cell lines into the extracellular space. Subsequent analysis of clinical blood samples from patients with breast cancer and age-adjusted healthy controls revealed an overall specificity of 99.0% and sensitivity of 80.0% for cancer detection. Remarkably, 81.5% of small T1 cancers were already CCN1-positive, while CCN1 concentrations in patients with benign breast lesions were below the threshold for breast cancer detection.

Generally, the CCN1 concentrations in the plasma of patients with other diseases such as acute kidney injury, sepsis, or autoimmune diseases such as rheumatoid arthritis were <0.5 ng/mL and therefore below the critical CCN1 concentration of our classifier of 0.69 ng/mL. Similarly, CCN1 concentrations of 0.62 ng/mL were found in coronary artery disease patients, but increased CCN1 concentrations were detected in the subgroup of patients with acute myocardial infarction with less than six hours after the onset of chest pain.

The authors concluded that with regard to clinical application, circulating CCN1 appears to be a diagnostically sensitive biomarker for early detection of breast cancer and can be therefore included in liquid biopsy panels encompassing other proteins or cell-free DNA. The study published on August 30, 2021 in the journal Clinical Chemistry.

Related Links:
University Medical Centre Hamburg-Eppendorf
Tecan


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more