We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Two Automated Hematology Analyzers Compared for Performance

By LabMedica International staff writers
Posted on 17 Dec 2020
Print article
Image: The Yumizen H2500 Automatic Hematology Analyzer (Photo courtesy of Horiba)
Image: The Yumizen H2500 Automatic Hematology Analyzer (Photo courtesy of Horiba)
A complete blood count (CBC) is a highly automated laboratory test. The use of highly advanced measurement methods increases the accuracy and sensitivity of the determination of individual hematological parameters, especially in the case of white blood cells differentiation.

It is important that the results of laboratory tests obtained using automated analyzers, which are currently able to perform more than 1,000 tests per day, are comparable, repeatable and reliable regardless of the analyzer used and the laboratory in which the analysis was performed.

Medical Laboratorians at the Medical University of Warsaw (Warsaw, Poland) collected 241 peripheral blood samples from adult patients. Samples of peripheral blood came from both healthy patients and those suffering from various pathologies. To perform comparative analysis of hematological parameters, complete blood count with leukocyte differentiation (CBC+ 5-DIFF) and a complete blood count (CBC) without leukocyte differentiation were used.

The complete blood count results were obtained using two automated hematology analyzers: the XN-2000 (Sysmex Corporation, Kobe, Japan) and the Yumizen H2500 (Horiba, Kyoto, Japan). The XN-2000 uses the following methods of fluorescent flow to determine all tested hematological parameters: cytometry, impedance and optical cytometry. Impedance method to count red blood cells (RBC) and platelets, and has an optical measurement channel for reticulocytes in which platelet count can also be measured. The Yumizen H2500 is a quantitative, multi-parameter, automatic hematological analyzer. It uses the double hydrodynamic focusing method, which includes measurement of polychromatic light absorbance and the impedance method.

The scientists reported that reliable leukocyte differentiation results were obtained for blood samples in which the number of white blood cells perceived using an automatic hematological analyzer was within the detection limits for both analyzers. Statistically significant differences were found for four hematological parameters: eosinophil count, immature granulocytes, mean corpuscular hemoglobin concentration (MCHC) and platelet distribution width (PDW).

The comparative study showed agreement between measurements of complete blood count parameters such as leukocyte count (WBC), red blood cell count (RBC), hemoglobin concentration (HGB), hematocrit (HCT), mean corpuscular volume (MCV), mean corpuscular hemoglobin (mean cell hemoglobin, MCH), red blood cell distribution width (RDW), platelet count (PLT), mean platelet volume (MPV), and plateletcrit (PCT).

The authors concluded that due to the existence of variability between the results obtained from different hematology analyzers, it is recommended that patient samples be analyzed in the same laboratory using the same analyzer, in order to avoid obtaining divergent results that could be misinterpreted. Incorrect interpretation may affect further clinical management and be a source of uncertainty. The study was published in the November, 2020 issue of the journal Practical Laboratory Medicine.

Related Links:
Medical University of Warsaw
Sysmex Corporation
Horiba


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The revolutionary autonomous blood draw technology is witnessing growing demands (Photo courtesy of Vitestro)

Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing

Blood drawing is performed billions of times each year worldwide, playing a critical role in diagnostic procedures. Despite its importance, clinical laboratories are dealing with significant staff shortages,... Read more