CD200 Expression Marks Leukemia Stem Cells in Human AML
By LabMedica International staff writers Posted on 17 Nov 2020 |
Image: The 5200 Fragment Analyzer system performs DNA QC and RNA QC for a broad range of samples including, gDNA, small RNA, cfDNA, large DNA fragments, and total RNA (Photo courtesy of Agilent Technologies).
Acute myeloid leukemia (AML) is organized as a hierarchy sustained by a minor population of leukemia stem cells (LSCs) with self-renewal capacity that drive disease. The LSC populations of AML exhibit phenotypic, genetic, and functional heterogeneity that contribute to therapy failure and relapse.
Progress toward understanding the mechanistic basis for therapy resistance in LSCs has been hampered by difficulties in isolating cell fractions that enrich for the entire heterogeneous population of LSCs within individual AML samples. Consequently, it is critical to study the properties of all LSCs within an individual sample to develop therapies to target these disease-sustaining cells and improve patient outcomes.
Clinical Scientists at the Princess Margaret Cancer Centre (Toronto, ON, Canada) and their colleagues collected blood and bone marrow (BM) samples from newly diagnosed AML patients and BM from healthy adults. Low-density mononuclear cells (MNCs) from all samples were isolated by Ficoll density centrifugation. Lineage-negative (Lin–) cells were obtained from blood and BM using StemSep column-based isolation (Stemcell Technologies Inc, Vancouver, BC, Canada).
CD200 cell surface expression on primary AML samples was detected using purified rat anti-human CD200 and other procedures. Flow cytometry was performed using a BD LSRII, and data were analyzed by using FlowJo software (BD Biosciences, San Jose, CA, USA). The scientists also used cell sorting and xenotransplantation studies as well as analysis of NPM1 and DNMT3a mutations in lymphoid and myeloid cells from xenografts. RNA was extracted from sorted AML fractions using the RNeasy Mini/Micro Kit (Qiagen Inc, Hilden, Germany) and was quantified by using the Fragment Analyzer (Agilent Technologies, Santa Clara, CA, USA).
The team showed that show that CD200 is present on a greater proportion of CD45dim blasts compared with more differentiated CD45high cells in AML patient samples. In 49/65 (75%) of AML cases we examined, CD200 was expressed on ≥10% of CD45dim blasts; of these, CD200 identified LSCs within the blast population in 9/10 (90%) samples tested in xenotransplantation assays. CD200+ LSCs could be isolated from CD200+ normal hematopoietic stem cells (HSCs) with the use of additional markers. Notably, CD200 expression captured both CD34– and CD34+ LSCs within individual AML samples. Analysis of highly purified CD200+ LSC-containing fractions from NPM1-mutated AMLs, which are commonly CD34–, exhibited an enrichment of primitive gene expression signatures compared with unfractionated cells.
The authors concluded that overall, their findings support CD200 as a novel LSC marker that is able to capture the entire LSC compartment from AML patient samples, including those with NPM1 mutation. The study was published on November 4, 2020 in the journal Blood Advances.
Related Links:
Princess Margaret Cancer Centre
Stemcell Technologies Inc
BD Biosciences
Qiagen Inc
Agilent Technologies
Progress toward understanding the mechanistic basis for therapy resistance in LSCs has been hampered by difficulties in isolating cell fractions that enrich for the entire heterogeneous population of LSCs within individual AML samples. Consequently, it is critical to study the properties of all LSCs within an individual sample to develop therapies to target these disease-sustaining cells and improve patient outcomes.
Clinical Scientists at the Princess Margaret Cancer Centre (Toronto, ON, Canada) and their colleagues collected blood and bone marrow (BM) samples from newly diagnosed AML patients and BM from healthy adults. Low-density mononuclear cells (MNCs) from all samples were isolated by Ficoll density centrifugation. Lineage-negative (Lin–) cells were obtained from blood and BM using StemSep column-based isolation (Stemcell Technologies Inc, Vancouver, BC, Canada).
CD200 cell surface expression on primary AML samples was detected using purified rat anti-human CD200 and other procedures. Flow cytometry was performed using a BD LSRII, and data were analyzed by using FlowJo software (BD Biosciences, San Jose, CA, USA). The scientists also used cell sorting and xenotransplantation studies as well as analysis of NPM1 and DNMT3a mutations in lymphoid and myeloid cells from xenografts. RNA was extracted from sorted AML fractions using the RNeasy Mini/Micro Kit (Qiagen Inc, Hilden, Germany) and was quantified by using the Fragment Analyzer (Agilent Technologies, Santa Clara, CA, USA).
The team showed that show that CD200 is present on a greater proportion of CD45dim blasts compared with more differentiated CD45high cells in AML patient samples. In 49/65 (75%) of AML cases we examined, CD200 was expressed on ≥10% of CD45dim blasts; of these, CD200 identified LSCs within the blast population in 9/10 (90%) samples tested in xenotransplantation assays. CD200+ LSCs could be isolated from CD200+ normal hematopoietic stem cells (HSCs) with the use of additional markers. Notably, CD200 expression captured both CD34– and CD34+ LSCs within individual AML samples. Analysis of highly purified CD200+ LSC-containing fractions from NPM1-mutated AMLs, which are commonly CD34–, exhibited an enrichment of primitive gene expression signatures compared with unfractionated cells.
The authors concluded that overall, their findings support CD200 as a novel LSC marker that is able to capture the entire LSC compartment from AML patient samples, including those with NPM1 mutation. The study was published on November 4, 2020 in the journal Blood Advances.
Related Links:
Princess Margaret Cancer Centre
Stemcell Technologies Inc
BD Biosciences
Qiagen Inc
Agilent Technologies
Latest Hematology News
- Next Generation Instrument Screens for Hemoglobin Disorders in Newborns
- First 4-in-1 Nucleic Acid Test for Arbovirus Screening to Reduce Risk of Transfusion-Transmitted Infections
- POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy
- First Affordable and Rapid Test for Beta Thalassemia Demonstrates 99% Diagnostic Accuracy
- Handheld White Blood Cell Tracker to Enable Rapid Testing For Infections
- Smart Palm-size Optofluidic Hematology Analyzer Enables POCT of Patients’ Blood Cells
- Automated Hematology Platform Offers High Throughput Analytical Performance
- New Tool Analyzes Blood Platelets Faster, Easily and Accurately
- First Rapid-Result Hematology Analyzer Reports Measures of Infection and Severity at POC
- Bleeding Risk Diagnostic Test to Reduce Preventable Complications in Hospitals
- True POC Hematology Analyzer with Direct Capillary Sampling Enhances Ease-of-Use and Testing Throughput
- Point of Care CBC Analyzer with Direct Capillary Sampling Enhances Ease-of-Use and Testing Throughput
- Blood Test Could Predict Outcomes in Emergency Department and Hospital Admissions
- Novel Technology Diagnoses Immunothrombosis Using Breath Gas Analysis
- Advanced Hematology System Allows Labs to Process Up To 119 Complete Blood Count Results per Hour
- Unique AI-Based Approach Automates Clinical Analysis of Blood Data