Automated Fluorescent Microbial Cell Counter Detects Urinary Tract Infection

By LabMedica International staff writers
Posted on 15 Jul 2020
Print article
Image: The QUANTOM Tx Microbial Cell Counter is an image-based, automated cell counter that can identify and count individual bacterial cells in minutes (Photo courtesy of Logos Biosystems).
Image: The QUANTOM Tx Microbial Cell Counter is an image-based, automated cell counter that can identify and count individual bacterial cells in minutes (Photo courtesy of Logos Biosystems).
Urinary tract infections (UTI) accounted for around 400,000 hospitalizations, resulting in an estimated cost burden of approximately USD 2.8 billion in the USA. Between 50% and 60% of adult women will have at least one UTI in their life, and close to 10% of postmenopausal women indicate that they had a UTI in the previous year.

A rapid urinalysis is usually conducted upon presentation with UTI‐related symptoms in patients. A rapid urinalysis screens the urine for ketones, proteins, reducing substances, red blood cells (RBC), white blood cells (WBC), nitrites, and pH levels outside the normal range (4.5 to 8.0). The most common pathogen associated with UTI globally is Escherichia coli.

Gastroenterologists and their associates at the Sinai Hospital (Baltimore, MD, USA) obtained clean‐catch urine samples from 10 healthy control subjects with a negative urinalysis result and 11 subjects with suspected UTI with a positive urinalysis and culture result for E. coli. Urine samples that received a positive result were plated onto blood agar and MacConkey medium for growth analysis. Urine samples were analyzed using the QUANTOM Tx Microbial Cell Counter (Logos Biosystems, Annandale, VA, USA) upon reception from the microbiology laboratory.

The scientists reported that the mean cellular concentration for the 11 E. coli‐positive samples was 1.01 × 108 cells/mL (range = 2.5 × 107–3.29 × 108 ± SD = 8.9 × 107). The average cellular concentration for the 10 control samples was 2.35 × 106 cells/mL (range = 9.42 × 105–5.93 × 106 ± SD = 1.56 × 106). The difference in cellular concentration between the E. coli‐positive and control groups was found to be statistically significant.

The authors concluded that the automated microbial cell counter represents a significant step toward high throughput, reproducible microbial cell observation, and quantification. A significant difference in cellular concentration was observed between E. coli‐positive UTI samples and controls measured with an automated microbial cell counter. Thus, automated microbial cell counters may serve important roles as preliminary screening tools in clinical diagnostic settings. The study was published on July 4, 2020 in the Journal of Clinical Laboratory Analysis.

Related Links:
Sinai Hospital
Logos Biosystems


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more