We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Automated Enzymatic Method Quantifies Pyruvate Kinase in Erythrocytes

By LabMedica International staff writers
Posted on 05 Mar 2020
Print article
Image: The Agilent Cary 60 UV-Vis Spectrophotometer is efficient, accurate and flexible, and is designed to meet immediate and future challenges (Photo courtesy of Agilent Technologies).
Image: The Agilent Cary 60 UV-Vis Spectrophotometer is efficient, accurate and flexible, and is designed to meet immediate and future challenges (Photo courtesy of Agilent Technologies).
A deficiency of red blood cell (RBC) pyruvate kinase (PK), inherited as an autosomal recessive trait, is the most common cause of hereditary nonspherocytic hemolytic anemia (HSHA). The hemolysis is owing to the inability of the PK-deficient RBCs to maintain adequate quantities of ATP.

Pyruvate kinase (PK) deficiency affects less than 1% of the population. As the most common cause of HSHA, testing for PK activity is commonly performed. PK activity is generally greater in reticulocytes than in mature RBCs and may explain the appearance of hemolytic anemia in patients with normal enzyme activity.

Scientists at the ARUP Institute (Salt Lake City, UT, USA) collected residual whole blood samples collected into tubes containing EDTA or heparin anticoagulant and sent to ARUP Laboratories were used after being deidentified. Because white blood cells contain 300 times the PK activity of RBCs, the two cell types were separated from each other and the plasma by using phthalate oil in a glass capillary tube that was centrifuged at 9,600g for five minutes and hemolysates were prepared.

PK activity was determined using a method proposed by the International Committee for Standardization in Hematology. PK catalyzes the reaction of phosphoenolpyruvate with ADP to form pyruvate and ATP. The pyruvate is reduced in the presence of lactate dehydrogenase and NADH to produce lactate and NAD+. For the manual method, the rate of absorbance decrease at 340 nm was determined using a Cary 60 spectrophotometer (Agilent Technologies, Santa Clara, CA, USA) and was used to derive the PK activity in conjunction with the molar absorptivity of 6,220 L/mol/cm. PK and hemoglobin (Hb) measurements were performed on a Roche cobas c501 analyzer (Roche Diagnostics, Basel, Switzerland).

The scientists reported that the accuracy of the automated PK assay was evaluated by comparing it with the manual method with 56 samples measured in two replicates over 10 days. PK activities ranged from 1.5 to 25.9 U/g Hb, and linear regression produced a slope where R2 = 0.93, indicating that the two methods produced the same results. Precision was evaluated by testing hemolysates in three replicates/day for 10 days. Within-run imprecision was 1.9% and 2.5% and total imprecision was 4.0% and 5.6% at 14.0 and 8.1 U/g Hb, respectively. The limit of blank was 0.0, and the limit of detection was 1.0 U/dL. Stability was determined in four sample types at three different temperatures; the changes were all was less than 10% when compared with t0. The current PK reference interval of 4.6 to 11.2 U/g Hb was verified.

The authors concluded that the ability to measure both components on a single automated platform and in the same hemolysate is an efficient method to replace a manual activity assay using two different analytical platforms. The study was published in the January 2020 issue of The Journal of Applied Laboratory Medicine.


Related Links:
ARUP Institute
Agilent Technologies
Roche Diagnostics


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Molecular Diagnostics

view channel
Image: Researchers have found a way to spot the debilitating disease Alzheimer\'s before it develops into dementia (Photo courtesy of 123RF)

Advanced Blood Test to Spot Alzheimer's Before Progression to Dementia

Alzheimer’s disease is well known for its slow development over many years, which typically leads to treatment interventions only after the disease has advanced to stages where it may be nearly impossible... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more

Pathology

view channel
Image: The new method is quick and easy, and can also be used by non-medical personnel. (Photo courtesy of Zoratto et al. Advanced Science 2024, edited)

New Blood Test Device Modeled on Leeches to Help Diagnose Malaria

Many individuals have a fear of needles, making the experience of having blood drawn from their arm particularly distressing. An alternative method involves taking blood from the fingertip or earlobe,... Read more