LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Diagnostic Efficacy of Immunomarkers in Fungal Bloodstream Infection

By LabMedica International staff writers
Posted on 05 Feb 2020
Print article
Image: The MILLIPLEX MAP Human Cytokine/Chemokine Magnetic Bead Panel - Premixed 30 Plex - Immunology Multiplex Assay (Photo courtesy of Merck).
Image: The MILLIPLEX MAP Human Cytokine/Chemokine Magnetic Bead Panel - Premixed 30 Plex - Immunology Multiplex Assay (Photo courtesy of Merck).
Fungemia is the presence of fungi or yeasts in the blood and is a life‐threatening condition with the global mortality rate surging more than fivefold in the past decade. It has been reported that the outcome depends on early and targeted treatment; thus, prompt diagnosis is essential at the early stage of infection.

Currently, early diagnosis of fungemia remains a complicated issue. Although blood culture remains the reference method for the detection of fungemia, this method takes 3‐5 days to generate positive results and also suffers from low sensitivity, which could not meet the requirement of early diagnosis and clinical guidance for fungemia.

Clinical Laboratory scientists at the Chinese PLA General Hospital (Beijing, China) included in their study 41 patients with fungemia who were compared with 57 patients with negative blood culture results. Blood samples for culture were taken from the patients for two to three times and inoculated using BACTEC PLUS Aerobic/F (Becton, Dickinson and Company, Franklin Lakes, NJ, USA) blood culture bottles. The isolations from blood culture were identified to species with VETIK YBC card (bioMérieux, Marcy-l'Étoile, France) and bioMérieux MALDI‐TOF‐MS.

The serum samples were analyzed using the xMAP Bead Array Platform (Luminex Corporation, Austin, TX, USA). A combination of 14 cytokines and chemokines was quantified using the reagents of selected ones from Human Cytokine 30‐Plex Panel Kit (Merck-Millipore, Burlington, MA, USA). Evaluated cytokines included the following: IL‐1β, ‐2, ‐3, ‐4, ‐6, ‐8, 10, 17, 12p70, INF‐γ, TNF‐α, G‐CSF, RANTES, and MIP‐1β. C-reactive protein (CRP) was measured using nephelometric method (Siemens BNII, Cardiophase, Erlangen, Germany), and procalcitonin (PCT) was measured by cobas 800 (Roche, Basel Switzerland) based on electrochemical luminescence technology.

The scientists reported that C‐reactive protein and procalcitonin were significantly higher compared with those in negative control group, while white blood cell, percentage of neutrophil, percentage of lymphocyte, and ratio of neutrophil and lymphocyte did not differentiate between two groups. Serum levels of IFN‐γ, TNF‐α, MIP‐1β, IL‐6, IL‐8, IL‐10, IL‐12p70, and IL‐17 were significantly higher in patients with fungemia compared with the control group. Combination of MIP‐1β and IL‐17 could improve the AUC, sensitivity, and specificity for the diagnosis of fungemia.

The authors concluded that they had found eight serum cytokines/chemokines that significantly increased in the fungemia group when compared with the culture‐negative control group. Among them, MIP‐1β and IL‐17 might be given more attention during the diagnosis of fungemia. The study was published on January 23, 2020 in the Journal of Clinical Laboratory Analysis.

Related Links:
Chinese PLA General Hospital
Becton, Dickinson and Company
Merck-Millipore
bioMérieux
Luminex Corporation
Siemens
Roche


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more