LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Glycoprotein-Specific Direct Platelet Autoantibody Testing in Immune Thrombocytopenia

By LabMedica International staff writers
Posted on 14 Jan 2020
Print article
Image: The NEO Iris is a fully automated immunohematology analyzer for in vitro diagnostic testing of human blood (Photo courtesy of Immucor)
Image: The NEO Iris is a fully automated immunohematology analyzer for in vitro diagnostic testing of human blood (Photo courtesy of Immucor)
Autoantibodies directed against platelet glycoproteins have long been accepted as a major pathophysiologic mechanism in immune thrombocytopenia (ITP), but platelet autoantibody (PA) testing has previously shown poor sensitivity for ITP diagnosis.

Direct assays for platelet autoantibodies, which measure antibodies on platelets, as opposed to indirect assays, which measure free antibodies in plasma, that are capable of detecting glycoprotein-specific autoantibodies are considered optimal for PA testing

Hematologists at the Massachusetts General Hospital (Boston, MA, USA) performed a comprehensive retrospective study of PA testing in adult patients with ITP strictly applying the criteria of the 2012 International Society on Thrombosis and Haemostasis (ISTH) and 2011 American Society of Hematology (ASH) guidelines. Of 986 PA assays performed, 485 assays in 368 patients met criteria and were included.

All PA assays meeting inclusion criteria were performed by using the commercially available PakAuto assay (Immucor, Brookfield, WI, USA), a direct and indirect solid-phase enzyme-linked immunosorbent assay (ELISA)-based test measuring antibodies against GPIIb/IIIa, GPIb/IX, and GPIa/IIa. This direct glycoprotein-specific PA assay measures antibodies eluted from the surface of platelets. A result was positive if optical density values were equal to or greater than two times the value obtained for the mean of the negative controls for the corresponding glycoprotein.

The scientists reported that the sensitivity and specificity of a positive test result for diagnosis of active ITP (n = 228 patients) were 90% and 78%, respectively. Sensitivity and specificity of a negative test result for clinical remission (n = 61 assays) were 87% and 91%. Antibodies against both glycoprotein IIb (GPIIb)/IIIa and GPIb/IX were required for the presence of antibodies against GPIa/IIa in patients with ITP. Logistic regression analysis revealed that more positive autoantibodies predicted more severe disease (relative to nonsevere ITP, relative risk ratio for severe ITP and refractory ITP was 2.27 and 3.09, respectively. Sixty-four patients with ITP had multiple PA assays performed longitudinally: all 10 patients achieving remission converted from positive to negative serologic results, and evidence for epitope spreading was observed in 35% of patients with ongoing active disease.

The authors concluded that glycoprotein-specific direct PA testing performed using ISTH recommendations in patients meeting ASH diagnostic criteria is sensitive and specific for ITP diagnosis and reliably confirms clinical remission. More glycoproteins targeted by autoantibodies predicts for more severe disease. The study was published on December 31, 2019 in the journal Blood Advances.

Related Links:
Massachusetts General Hospital
Immucor


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more