Methods Compared to Diagnose Schistosomiasis Japonica

By LabMedica International staff writers
Posted on 28 Mar 2019
Print article
Image: The Maxwell 16 instrument used for genomic DNA isolation (Photo courtesy of Promega).
Image: The Maxwell 16 instrument used for genomic DNA isolation (Photo courtesy of Promega).
Zoonotic schistosomiasis in Asia, caused by Schistosoma japonicum, remains a major public health concern in China and the Philippines. If left untreated, it will develop into a chronic condition characterized by hepatosplenic disease and impaired physical and cognitive development.

There are three major categories of methods available for schistosomiasis diagnosis: parasitological detection (e.g. the Kato-Katz (KK) method); serology, including antibody-detection (AbD) and antigen-detection (AgD); and molecular assays (e.g. circulating nucleic acids detection).

A team of scientists collaborating with the QIMR Berghofer Medical Research Institute (Brisbane, Australia) collected clinical samples of feces and blood from 412 subjects from Northern Samar, the Philippines, in 2015. Serum samples of healthy individuals were obtained from Heilongjiang Province, a non-endemic area for schistosomiasis in China. For the KK method slides were examined under a light microscope by experienced laboratory technicians. Infection intensity was presented as the number of eggs per gram of feces (EPG). For accuracy determination, 10% of slides were randomly selected and re-examined by an experienced microscopist.

Genomic DNA isolation of fecal samples was performed using the Maxwell 16 Instrument. Serum DNA extraction was performed using a ChemagicTM360 instrument. Droplet digital polymerase chain reaction (ddPCR) assays was performed and following PCR amplification, the plate was transferred to a QX200 Droplet Reader for analysis. Diagnostic candidates for schistosomiasis japonica by enzyme-linked immunosorbent assay (ELISA) were also evaluated.

The team reported that compared with the ddPCR assay analyzing DNA from feces, exhibited the highest sensitivity, the recombinant antigens of SjSAP4 + Sj23-LHD-ELISA had the best accuracy (67.72%) among all five ELISA assays assessed. Schistosomiasis prevalence determined by the SjSAP4 + Sj23-LHD-ELISA and ddPCRs was similar and was at least 2.5 times higher than obtained with the KK method. However, the agreement between these assays was low. In terms of cost and logistical convenience, the SjSAP4 + Sj23-LHD-ELISA represent a cost-effective assay with considerable diagnostic merits. In contrast, although the ddPCR assays exhibited a high level of diagnostic performance, the high cost and the need for specialized equipment presents a major obstacle in their application in screening campaigns.

The authors concluded that the SjSAP4 + Sj23-LHD-ELISA represents a cost-effective tool for the diagnosis of schistosomiasis that could prove an important component in the monitoring of integrated control measures as elimination draws closer, whereas the ddPCR assays, in addition to their high sensitivity and specificity, are capable of quantifying infection intensity. The study was published on March 4, 2019, in the journal PLoS Neglected Tropical Diseases.

Related Links:
QIMR Berghofer Medical Research Institute

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more