We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

NIV Test Developed for Fetal Rhesus Factor

By LabMedica International staff writers
Posted on 30 May 2018
Print article
Image: Administration of anti-D immunoglobulin is a routine occurrence in midwifery practice and has had a significant impact on the outcomes for babies previously at risk of hemolytic disease of the fetus and newborn (Photo courtesy of The Royal College of Midwives).
Image: Administration of anti-D immunoglobulin is a routine occurrence in midwifery practice and has had a significant impact on the outcomes for babies previously at risk of hemolytic disease of the fetus and newborn (Photo courtesy of The Royal College of Midwives).
If the blood of a pregnant woman is rhesus-negative (Rh-negative) and the blood of the fetus is rhesus-positive (Rh-positive), the woman may develop antibodies, which can cause severe harm to subsequent children in particular.

A test has now become available to determine the fetal Rhesus factor already before birth. This is a non-invasive procedure, in which the fetus is not touched. Instead, the test analyses so-called cell-free fetal DNA circulating in the maternal plasma.

All Rh-negative pregnant women in Germany currently receive a standard dose of anti-D immunoglobulin. These antibodies are used to prevent sensitization by catching erythrocytes that reach the mother's bloodstream from the fetal bloodstream already before birth. Human anti-D immunoglobulin from sensitized donors is used for this prophylaxis. After birth, the infant's Rhesus factor is determined using a blood sample of the infant (postnatal testing). If the blood of the newborn is Rh-positive, the mother receives another anti-D prophylaxis.

The German Institute for Quality and Efficiency in Health Care (IQWiG, Cologne, Germany) has now examined whether the management of prophylaxis based on a new test has advantages or disadvantages for the children or for the expectant mothers. The final results are now available. According to the findings, there are no studies to answer this question. The reliability of the new test is as high as the reliability of the conventional test used after birth, however. In principle, this allows limiting prenatal anti-D prophylaxis only to those Rh-negative pregnant women whose fetus is Rh-positive according to the prenatal test. Currently, about 15 % of all pregnant women receive the prophylaxis, corresponding to about 110,000 pregnant women per year. Implementing the new test could reduce this number to about 60,000.

The team wanted to know whether the introduction of the new test can have health advantages or disadvantages for children or mothers, e.g. increasing the occurrence of hemolytic anemia or decreasing the occurrence of side effects of the prophylaxis. However, there are studies that provide information on how reliable the prenatal test is in determining the child's Rhesus factor. The reliability is comparatively high, which is referred to as "high diagnostic accuracy": The test correctly identifies 99.9% of all Rh-positive fetuses (sensitivity) and 99.1% of all Rh-negative fetuses (specificity). This means that 0.1% of pregnant women who would require anti-D prophylaxis before birth would not receive this prophylaxis if this decision was based on the test result. Hence, the prenatal test is as reliable as testing after birth.

The authors of the report stated that if the prenatal test was to replace the postnatal test, this would increase neither the rate of prophylaxis that is falsely withheld nor the rate of hemolytic anemia to a measurable extent. This is because both tests are equivalent. It is recommended, however, to evaluate the procedure first and particularly to test how high the sensitivity of the new prenatal test actually is under the health care conditions in Germany. The final report was issued on May 15, 2018.

Related Links:
German Institute for Quality and Efficiency in Health Care

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: The fastGEN BCR::ABL1 Cancer kit offers a way to personalize treatment strategies for leukemia (Photo courtesy of BioVendor MDx)

First of Its Kind NGS Assay for Precise Detection of BCR::ABL1 Fusion Gene to Enable Personalized Leukemia Treatment

The BCR::ABL1 fusion gene plays a key role in the pathogenesis of several blood cancers, particularly chronic myeloid leukemia (CML). This gene results from a chromosomal translocation that causes constitutive... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The new method is quick and easy, and can also be used by non-medical personnel. (Photo courtesy of Zoratto et al. Advanced Science 2024, edited)

New Blood Test Device Modeled on Leeches to Help Diagnose Malaria

Many individuals have a fear of needles, making the experience of having blood drawn from their arm particularly distressing. An alternative method involves taking blood from the fingertip or earlobe,... Read more