We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Flow Cytometry Technique Assessed for Signaling Pathways

By LabMedica International staff writers
Posted on 24 Apr 2018
Print article
Image: The Navios clinical flow cytometer (Photo courtesy of Beckman Coulter).
Image: The Navios clinical flow cytometer (Photo courtesy of Beckman Coulter).
Platelet aggregation is a key parameter in arterial thrombosis, leading to myocardial infarction or ischemic stroke. Platelets have several receptors sensitive to different stimuli and drugs that modulate aggregation with potential critical clinico-pathological significance.

Platelet intracellular signaling is essential for platelet function but difficult to study because of the small size and the need for delicate manipulation of platelets and because the reference techniques require large cell volumes and sample preparation. Flow cytometry is often used in routine clinical laboratories.

A team of scientists collaborating with CHU Saint-Etienne, Hôpital Nord (Saint-Etienne, France) assessed degree of platelet vasodilator-stimulated phosphoprotein (VASP) phosphorylation on patients hospitalized for a non-cardio-embolic ischemic stroke, included in an observational study. The patients, 12 men, seven women with a mean age of 72 years, were enrolled in the study between November 2014 and September 2015, and were treated orally with a regular daily dose of 75 mg of clopidogrel for at least five days to be at steady state, before blood was drawn.

The VASP assay was performed using the PLT VASP/P2Y12 kit. In addition, the Platelet PerFix flow cytometry method was developed from the PerFix EXPOSE kit provided for leukocytes. The team adapted the manufacturer's instruction for this kit. The fixation, permeabilization, staining and washing reagents of the kit were used. Each step was performed at room temperature. Platelets were analyzed on a Navios cytometer using Navios software (Beckman-Coulter) within one hour after the preparation was completed. Maximum platelet aggregation induced by adenosine diphosphate (ADP) was measured by Light Transmittance Aggregometry or LTA.

The investigators found poor agreement between prevention by adenosine diphosphate (ADP) of PGE1-induced cAMP-mediated VASP phosphorylation and ADP induced aggregation assessed by Light Transmittance Aggregometry. They did find a significant correlation between the PLT VASP/P2Y12 kit and the PerFix EXPOSE kit. The PerFix EXPOSE kit may also be helpful to monitor adverse effects of second-generation tyrosine kinase inhibitors on platelets as this new method can detect low responders to clopidogrel. The study was published originally on-line on February 16, 2018, in the journal Practical Laboratory Medicine.

Related Links:
CHU Saint-Etienne

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The revolutionary autonomous blood draw technology is witnessing growing demands (Photo courtesy of Vitestro)

Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing

Blood drawing is performed billions of times each year worldwide, playing a critical role in diagnostic procedures. Despite its importance, clinical laboratories are dealing with significant staff shortages,... Read more