New Immunoassay Evaluated for Toxoplasmosis
By LabMedica International staff writers Posted on 25 Apr 2017 |
Image: Indirect fluorescent antibody test for Toxoplasma gondii, diffuse staining is considered positive (Photo courtesy of SPL).
The infection by Toxoplasma gondii, an obligate intracellular parasite, is generally benign but can be particularly severe during pregnancy, leading to malformations of the fetus or a series of complications in the newborn.
Currently, there are several analytical systems for the detection of antibodies, with different level of automation, such as Enzyme-Linked Immunosorbent Assay (ELISA), Chemiluminescence Immunoassay (CLIA) and Enzyme Linked Fluorescent Assay (ELFA) able, depending on the instrument used, to process a large number of samples in a short time.
Microbiologists at the Legnano Hospital examined 301 sera samples from women who came to their center for the routine follow-up in pregnancy and were divided into three groups: Group 1:106 samples from non-immune women; Group 2:100 samples from women with past infection; and Group 3: 95 samples from women with positive or equivocal immunoglobulin M (IgM) (82 with positive IgG and 13 with negative IgG).
The scientists routinely tested samples using chemiluminescence LIAISON XL system for IgG and IgM. In positive subjects for IgM, samples are tested using an ELFA test. All samples were also tested with TGS TA system for detecting IgG and IgM and, for Group 3, IgG avidity (TGS TA Toxoplasma IgG, Toxoplasma IgM, Toxoplasma IgG Avidity.
The overall concordance of the IgG results between LIAISON XL and TGS TA was 99.3%: 100% in Group 1, 98% in Group 2 and 100% in Group 3. The overall concordance of the IgM results between LIAISON XL and TGS TA was 93.9%: 100% in Group 1, 94% in Group 2 and 82.8% in Group 3. In Group 3, the concordance between the results of the IgG avidity with the ELFA and TGS TA tests was 81.7%. Comparing the clinical diagnosis obtained with the protocol and that of the TGS TA system, the overall concordance was 92.7%: 100% in Group 1, 92.0% in Group 2 and 78.9% in Group 3.
The authors concluded that the overall concordance of IgG antibodies is excellent for both protocols. The TGS TA avidity test seems to predict earlier the maturation of the IgG compared to the ELFA test since many samples with low avidity with the ELFA were seen with moderate avidity with TGS TA and all those with borderline avidity with the ELFA were seen with high avidity with TGS TA. This system is shown to be a valuable tool with overall good clinical correlation and able to clearly identify nonspecific subjects, those with a non-recent infection.
Currently, there are several analytical systems for the detection of antibodies, with different level of automation, such as Enzyme-Linked Immunosorbent Assay (ELISA), Chemiluminescence Immunoassay (CLIA) and Enzyme Linked Fluorescent Assay (ELFA) able, depending on the instrument used, to process a large number of samples in a short time.
Microbiologists at the Legnano Hospital examined 301 sera samples from women who came to their center for the routine follow-up in pregnancy and were divided into three groups: Group 1:106 samples from non-immune women; Group 2:100 samples from women with past infection; and Group 3: 95 samples from women with positive or equivocal immunoglobulin M (IgM) (82 with positive IgG and 13 with negative IgG).
The scientists routinely tested samples using chemiluminescence LIAISON XL system for IgG and IgM. In positive subjects for IgM, samples are tested using an ELFA test. All samples were also tested with TGS TA system for detecting IgG and IgM and, for Group 3, IgG avidity (TGS TA Toxoplasma IgG, Toxoplasma IgM, Toxoplasma IgG Avidity.
The overall concordance of the IgG results between LIAISON XL and TGS TA was 99.3%: 100% in Group 1, 98% in Group 2 and 100% in Group 3. The overall concordance of the IgM results between LIAISON XL and TGS TA was 93.9%: 100% in Group 1, 94% in Group 2 and 82.8% in Group 3. In Group 3, the concordance between the results of the IgG avidity with the ELFA and TGS TA tests was 81.7%. Comparing the clinical diagnosis obtained with the protocol and that of the TGS TA system, the overall concordance was 92.7%: 100% in Group 1, 92.0% in Group 2 and 78.9% in Group 3.
The authors concluded that the overall concordance of IgG antibodies is excellent for both protocols. The TGS TA avidity test seems to predict earlier the maturation of the IgG compared to the ELFA test since many samples with low avidity with the ELFA were seen with moderate avidity with TGS TA and all those with borderline avidity with the ELFA were seen with high avidity with TGS TA. This system is shown to be a valuable tool with overall good clinical correlation and able to clearly identify nonspecific subjects, those with a non-recent infection.
Latest Immunology News
- Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies
- AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell
- Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment
- Testing Method Could Help More Patients Receive Right Cancer Treatment
- Groundbreaking Test Monitors Radiation Therapy Toxicity in Cancer Patients
- State-Of-The Art Techniques to Investigate Immune Response in Deadly Strep A Infections
- Novel Immunoassays Enable Early Diagnosis of Antiphospholipid Syndrome
- New Test Could Predict Immunotherapy Success for Broader Range Of Cancers
- Simple Blood Protein Tests Predict CAR T Outcomes for Lymphoma Patients
- Cell Sorter Chip Technology to Pave Way for Immune Profiling at POC
- Chip Monitors Cancer Cells in Blood Samples to Assess Treatment Effectiveness
- Automated Immunohematology Approaches Can Resolve Transplant Incompatibility
- AI Leverages Tumor Genetics to Predict Patient Response to Chemotherapy
- World’s First Portable, Non-Invasive WBC Monitoring Device to Eliminate Need for Blood Draw
- Predictive T-Cell Test Detects Immune Response to Viruses Even Before Antibodies Form
- Single Blood Draw to Detect Immune Cells Present Months before Flu Infection Can Predict Symptoms