We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Diagnostic Predictive Value of Platelet Indices Evaluated

By LabMedica International staff writers
Posted on 31 Aug 2016
Print article
Image: The XT 2000i fully automated hematology analyzer (Photo courtesy of Sysmex).
Image: The XT 2000i fully automated hematology analyzer (Photo courtesy of Sysmex).
The two main causes of thrombocytopenia excluding pseudo thrombocytopenia are increase destruction or peripheral consumption also known as hyper-destructive thrombocytopenia. Decreased platelet productions or hypo-production thrombocytopenia are associated with a number of bone marrow diseases.

The gold standard method for discriminating the causes of immune thrombocytopenic purpura (ITP), disseminated intravascular coagulation (DIC), and thrombotic thrombocytopenic purpura (TTP) is bone marrow examination. Due to its invasiveness and being unfriendly for the patients, this procedure is not recommended as first line diagnosis. ITP still remains a diagnosis by exclusion due to lack of accurate clinical and laboratory parameters.

Hematologists at the College of Health Sciences (Addis Ababa University, Ethiopia) conducted a prospective cross-sectional study on 83 thrombocytopenic patients whose platelet count was less than 150 × 109/L. From these, 50 patients had hypoproductive and the rest 33 had Immune Thrombocytopenia Purpura (ITP). Age and sex matched 42 healthy controls were included as a comparative group. Bone marrow examination was performed in all 50 hypoproductive patients and in 10 of the 33 ITP patients as part of their medical follow up and diagnosis. Females were the predominant study participants in ITP patients, while males were predominant in the hypo productive group.

Blood sample for complete blood count (CBC) analysis was collected into 5 mL EDTA anti-coagulated tube and CBC analysis was performed using the XT 2000i fully automated hematology analyzer (Sysmex Corporation, Kobe, Japan). This analyzer measures white blood cells (WBC) and reticulocytes with an optical detector block based on the flow cytometry principle, red blood cells (RBC) and platelet counts are analyzed via the impedance method. The performance of the instrument was monitored by running quality control materials. A peripheral blood smear was also reviewed to estimate platelet counts, rule out pseudo thrombocytopenia and fragments of cells like shistocytes.

All platelet indices were significantly higher in ITP patients than in hypoproductive thrombocytopenic patients. In particular mean platelet volume (MPV) and Platelet Large Cell-Ratio (P-LCR) have larger area under ROC curve, 0.876 and 0.816, respectively, indicating a better predictive capacity, sensitivity and specificity in discriminating the two causes of thrombocytopenia. The indices were still significantly higher in ITP patients compared to 42 healthy controls. A significant negative correlation was observed between platelet count and platelet indices in ITP patients.

The authors concluded that Platelet Distribution Width (PDW), MPV, and P-LCR help in predicting thrombocytopenic patients as having ITP or hypoproductive thrombocytopenia. If these indices are used in line with other laboratory and clinical information, they may help in delaying/ avoiding unnecessary bone marrow aspiration in ITP patients or supplement a request for bone morrow aspiration or biopsy in hypoproductive thrombocytopenic patients. The study was published on July 1, 2016, in the journal BMC Hematology.

Related Links:
Addis Ababa University
Sysmex
Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: The new blood test identifies key biomarkers of osteoarthritis (Photo courtesy of Shutterstock)

Blood Test Predicts Knee Osteoarthritis Eight Years Before Signs Appears On X-Rays

Osteoarthritis (OA) is the most prevalent form of arthritis, impacting millions worldwide and resulting in significant economic and social costs. Although no cure exists currently, the effectiveness of... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The Sampler device could revolutionize sample collection for diagnostic tests (Photo courtesy of ReadyGo Diagnostics)

First of Its Kind Universal Tool to Revolutionize Sample Collection for Diagnostic Tests

The COVID pandemic has dramatically reshaped the perception of diagnostics. Post the pandemic, a groundbreaking device that combines sample collection and processing into a single, easy-to-use disposable... Read more