LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Chemical Sensor Rapidly Detects Fungal Infections

By LabMedica International staff writers
Posted on 19 May 2016
Print article
Image: Candida albicans growing on Sabouraud agar (Photo courtesy of Dr. William Kaplan / CDC).
Image: Candida albicans growing on Sabouraud agar (Photo courtesy of Dr. William Kaplan / CDC).
An elevated concentration of D-arabitol, a simple sugar alcohol, in urine, especially compared to that of L-arabitol or creatinine, is indicative of a fungal infection, which can become deadly.

In healthy humans these forms, known as D-arabitol and L-arabitol, are formed in roughly the same amounts; however, cells of Candida species produce only D-arabitol. The relative increase in the concentration of this enantiomer in body fluids can therefore herald infection.

Scientists at the Institute of Physical Chemistry of the Polish Academy of Sciences (Warsaw, Poland) devised, fabricated, and tested chemical sensors determining D-arabitol. These chemosensors comprised the quartz crystal resonator (QCR) or extended-gate field-effect transistor (EG-FET) transducers integrated with molecularly imprinted polymer (MIP) film recognition units.

The polymer film with molecular cavities binding D-arabitol was prepared using the molecular imprinting technique. The process began by dissolving D-arabitol in acetonitrile. Then boric acid labeled with bithiophene, whose molecules bound to the D-arabitol in particular positions, was added to the solution. The bithiophene substituent permitted the electrochemical polymerization of the solution. A polymer film having a rigid structure was thus created, from which all that was needed was to rinse out the D-arabitol molecules to obtain a film with molecular cavities of the desired shape and properties.

The detection polymer films produced a thickness of about 200 nanometers. They are deposited either on gold electrodes, or on quartz resonators. After immersing a sample taken from a patient in the solution, D-arabitol particles get stuck in the molecular cavities of the films and depending on the method of detection, either change the flow of current through a field-effect transistor having a gate connected to an electrode or the oscillation resonance frequency of a piezoelectric resonator. The chemical sensor enabled the detection time of fungi to be shortened from the current couple of days to just a few minutes.

With the QCR and EG-FET chemosensors, the D-arabitol concentration was determined under flow-injection analysis and stagnant-solution binding conditions, respectively. Selectivity with respect to common interferences, and L-arabitol in particular, of the devised chemosensors was superior. Limits of detection and linear dynamic concentration ranges of the QCR and EG-FET chemosensors were 150 µM and 150µM to 1.25 mM as well as and 120 µM to 1.00 mM, respectively, being lower than the d-arabitol concentrations in urine of patients with invasive candidiasis, which was greater than 220 μM. The authors concluded that the devised chemosensors are suitable for early diagnosis of fungal infections caused by Candida sp. yeasts. The study was published in the May 2016 issue of the journal Biosensors and Bioelectronics.

Related Links:
Institute of Physical Chemistry of the Polish Academy of Sciences


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Liquid Ready-To-Use Lp(a) Reagent
Lipoprotein (a) Reagent

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more