Cryopreservation Significantly Extends Shelf Life of Blood
By LabMedica International staff writers Posted on 02 Dec 2014 |
Image: The membrane-based microfluidic device for the deglycerolization of red blood cells (Photo courtesy of Oregon State University).
A method to rapidly prepare frozen red blood cells for transfusions has been reported, which may offer an important new way to manage the world's blood supply.
While it is possible to cryopreserve human red blood cells in the presence of 40% glycerol, this is rarely done because of the time-consuming process to thaw and remove the glycerol from the blood and this can take an hour or more and makes it logistically difficult to use frozen blood.
Bioengineers at the Oregon State University (Corvallis, OR, USA) fabricated an appliance for the deglycerolization of red blood cells (RBC) using a microfluidic device consisting of two microchannels separated by a dialysis membrane. They used a mathematical model describing mass transfer within the device and show that the predictions are consistent with experimental measurements of solution composition and hemolysis at the device outlet.
The device consisted of a two laser-patterned Kapton sheets (DuPont, Wilmington, DE, USA), an AN69 hemodialysis membrane, and a clear acrylic housing. The device was sealed by tightening screws around the perimeter of the housing using a torque wrench to ensure even pressure distribution around the plates. Syringes filled with the desired solutions were connected to the device and 20-gauge blunt dispensing needles. The syringes were then loaded onto syringe pumps (New Era Pump Systems; Farmingdale, NY, USA) to introduce fluids into the device.
The scientists found that frozen-thawed RBCs can be flowed through a microfluidic membrane device without causing excessive mechanical damage; predictions of solution composition and cell volume are in reasonable agreement with investigational data. This opens opportunities for model-guided design of microfluidic deglycerolization processes. Using a four-stage microfluidic process, it is theoretically possible to remove glycerol in less than three minutes, more than an order of magnitude faster than current deglycerolization methods.
Adam Z. Higgins, PhD, an associate professor and coauthor of the study said, “Only a small fraction of our blood supply is now frozen, because it's often impractical to wait so long when a transfusion is needed immediately. Because of that, our entire system depends on constantly balancing the use and supply of blood products that can only last six weeks or less with refrigeration. This is difficult, and can lead to loss of outdated blood, periodic shortages, and other inefficiencies that could be solved with the use of frozen blood.” The study was published on October 28, 2014, in the journal Biomicrofluidics.
Related Links:
Oregon State University
DuPont
New Era Pump Systems
While it is possible to cryopreserve human red blood cells in the presence of 40% glycerol, this is rarely done because of the time-consuming process to thaw and remove the glycerol from the blood and this can take an hour or more and makes it logistically difficult to use frozen blood.
Bioengineers at the Oregon State University (Corvallis, OR, USA) fabricated an appliance for the deglycerolization of red blood cells (RBC) using a microfluidic device consisting of two microchannels separated by a dialysis membrane. They used a mathematical model describing mass transfer within the device and show that the predictions are consistent with experimental measurements of solution composition and hemolysis at the device outlet.
The device consisted of a two laser-patterned Kapton sheets (DuPont, Wilmington, DE, USA), an AN69 hemodialysis membrane, and a clear acrylic housing. The device was sealed by tightening screws around the perimeter of the housing using a torque wrench to ensure even pressure distribution around the plates. Syringes filled with the desired solutions were connected to the device and 20-gauge blunt dispensing needles. The syringes were then loaded onto syringe pumps (New Era Pump Systems; Farmingdale, NY, USA) to introduce fluids into the device.
The scientists found that frozen-thawed RBCs can be flowed through a microfluidic membrane device without causing excessive mechanical damage; predictions of solution composition and cell volume are in reasonable agreement with investigational data. This opens opportunities for model-guided design of microfluidic deglycerolization processes. Using a four-stage microfluidic process, it is theoretically possible to remove glycerol in less than three minutes, more than an order of magnitude faster than current deglycerolization methods.
Adam Z. Higgins, PhD, an associate professor and coauthor of the study said, “Only a small fraction of our blood supply is now frozen, because it's often impractical to wait so long when a transfusion is needed immediately. Because of that, our entire system depends on constantly balancing the use and supply of blood products that can only last six weeks or less with refrigeration. This is difficult, and can lead to loss of outdated blood, periodic shortages, and other inefficiencies that could be solved with the use of frozen blood.” The study was published on October 28, 2014, in the journal Biomicrofluidics.
Related Links:
Oregon State University
DuPont
New Era Pump Systems
Latest Technology News
- New Diagnostic System Achieves PCR Testing Accuracy
- DNA Biosensor Enables Early Diagnosis of Cervical Cancer
- Self-Heating Microfluidic Devices Can Detect Diseases in Tiny Blood or Fluid Samples
- Breakthrough in Diagnostic Technology Could Make On-The-Spot Testing Widely Accessible
- First of Its Kind Technology Detects Glucose in Human Saliva
- Electrochemical Device Identifies People at Higher Risk for Osteoporosis Using Single Blood Drop
- Novel Noninvasive Test Detects Malaria Infection without Blood Sample
- Portable Optofluidic Sensing Devices Could Simultaneously Perform Variety of Medical Tests
- Point-of-Care Software Solution Helps Manage Disparate POCT Scenarios across Patient Testing Locations
- Electronic Biosensor Detects Biomarkers in Whole Blood Samples without Addition of Reagents
- Breakthrough Test Detects Biological Markers Related to Wider Variety of Cancers
- Rapid POC Sensing Kit to Determine Gut Health from Blood Serum and Stool Samples
- Device Converts Smartphone into Fluorescence Microscope for Just USD 50
- Wi-Fi Enabled Handheld Tube Reader Designed for Easy Portability