Automated Soluble Fibrin Assays Evaluated

By LabMedica International staff writers
Posted on 26 Dec 2013
Print article
Image: Micrograph of acute thrombotic microangiopathy disseminated intravascular coagulation (Photo courtesy of Nephron).
Image: Micrograph of acute thrombotic microangiopathy disseminated intravascular coagulation (Photo courtesy of Nephron).
The soluble fibrin monomer (sFM) assay has the potential to be used both as an aid in the diagnosis of disseminated intravascular coagulation (DIC) and as a thrombotic marker.

The sFM test differs from the D-dimer (Ddi) assay in that it detects a much earlier produced fragment produced only by thrombin action on fibrinogen, whereas Ddi is a much later produced fragment formed by plasmin cleavage of cross-linked fibrin.

Scientists at the Karolinska University Hospital (Solna, Sweden) compared two commercially available automated sFM assays in the routine hospital setting using samples obtained from the general hospital ward and the emergency room. The results obtained with the two automated assays were compared with each other and with the results obtained using the routine semiquantitative hemagglutination assay.

The study showed that both automated assays, the LIAtest sFM assay (Diagnostica Stago; Genevilliers, France) and the LPIA-Iatro SF assay (Mitsubishi Kagaku Bio-Clinical Laboratories; Tokyo, Japan) were analogous with each other. No patient sample previously classified as positive would be missed, but with the higher sensitivity in the automated tests, more samples are positive.

The authors concluded that both automated tests are suitable for routine laboratory use. Both assays had the advantage over the hemagglutination assay in that previously frozen samples could be used, and the assays are easier and quicker to perform. The LIA sFM Stago has slightly better sensitivity but has a tendency to lower specificity than the Iatro SF test. The study was published in the December 2103 issue of the International Journal of Laboratory Hematology.

Related Links:

Karolinska University Hospital
Diagnostica Stago 
Mitsubishi Kagaku Bio-Clinical Laboratories


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more