Factors Affecting Plasma DNA Analysis Evaluated
By LabMedica International staff writers Posted on 21 May 2018 |

Image: The RainDrop digital PCR system (Photo courtesy of RainDance Technologies).
There is vast potential in precision-medicine methods of both detecting and monitoring disease by looking for indications of cancer mutations in cell-free DNA (cfDNA), circulating in the blood. However, there are many factors that can significantly alter these samples as they are collected and analyzed.
Circulating tumor DNA (ctDNA) analysis relies on detection and quantification of these mutations, against a background of cfDNA contributed by peripheral blood cells and other tissues. Total cfDNA and tumor-specific ctDNA levels in plasma vary considerably across cancer patients, cancer types and disease stages as well as during longitudinal follow-up of each patient.
Scientists from the Translational Genomics Research Institute (Phoenix, AZ, USA) designed a multiplexed droplet digital polymerase chain reaction (ddPCR) assay targeting nine single copy genomic loci. They prepared digital PCR reactions and performed thermocycling using DNA Engine Tetrad 2 and they measured droplet fluorescence using RainDrop Digital PCR Sense Instrument and analyzed results using accompanying software. To evaluate whether their ddPCR assay performed as expected, they analyzed known quantities of sheared DNA fragments with predetermined size and compared the results with expected theoretical yields.
Healthy volunteer and clinical plasma samples included in comparison of immediately processed and archived samples were collected. Samples from seven independent clinical cohorts were included in this analysis, including patients diagnosed with melanoma, cholangiocarcinoma and rectal cancer as well as healthy volunteers. For assessment of sequencing performance guided by ddPCR results, the team quantified cfDNA from commercially obtained control plasma samples using ddPCR and prepared whole genome sequencing libraries using ThruPLEX DNA-Seq.
The scientists evaluated effects of DNA extraction methods and blood collection tubes on cfDNA yield and fragment size, and developed a multiplexed droplet digital PCR (ddPCR) assay with five short and four long amplicons targeting single copy genomic loci. Using this assay, they compared seven cfDNA extraction kits and found cfDNA yield and fragment size vary significantly. They also compared three blood collection protocols using plasma samples from 23 healthy volunteers (EDTA tubes processed within one hour and Cell-free DNA Blood Collection Tubes processed within 24 and 72 hours) and found no significant differences in cfDNA yield, fragment size and background noise between these protocols. In 219 clinical samples, cfDNA fragments were shorter in plasma samples processed immediately after venipuncture compared to archived samples, suggesting contribution of background DNA by lysed peripheral blood cells.
Muhammed Murtaza, MD, PhD, the senior author of the study, said, “In order for us to rely on sequencing results and evidence of cancer mutations from these samples and to make valid recommendations for treating physicians, we must ensure they have been collected and processed appropriately. We developed this new quality-control assay to ensure we can confirm reliability using a very small volume of a patient’s blood sample.” The study was published on May 9, 2018, in the journal Scientific Reports.
Related Links:
Translational Genomics Research Institute
Circulating tumor DNA (ctDNA) analysis relies on detection and quantification of these mutations, against a background of cfDNA contributed by peripheral blood cells and other tissues. Total cfDNA and tumor-specific ctDNA levels in plasma vary considerably across cancer patients, cancer types and disease stages as well as during longitudinal follow-up of each patient.
Scientists from the Translational Genomics Research Institute (Phoenix, AZ, USA) designed a multiplexed droplet digital polymerase chain reaction (ddPCR) assay targeting nine single copy genomic loci. They prepared digital PCR reactions and performed thermocycling using DNA Engine Tetrad 2 and they measured droplet fluorescence using RainDrop Digital PCR Sense Instrument and analyzed results using accompanying software. To evaluate whether their ddPCR assay performed as expected, they analyzed known quantities of sheared DNA fragments with predetermined size and compared the results with expected theoretical yields.
Healthy volunteer and clinical plasma samples included in comparison of immediately processed and archived samples were collected. Samples from seven independent clinical cohorts were included in this analysis, including patients diagnosed with melanoma, cholangiocarcinoma and rectal cancer as well as healthy volunteers. For assessment of sequencing performance guided by ddPCR results, the team quantified cfDNA from commercially obtained control plasma samples using ddPCR and prepared whole genome sequencing libraries using ThruPLEX DNA-Seq.
The scientists evaluated effects of DNA extraction methods and blood collection tubes on cfDNA yield and fragment size, and developed a multiplexed droplet digital PCR (ddPCR) assay with five short and four long amplicons targeting single copy genomic loci. Using this assay, they compared seven cfDNA extraction kits and found cfDNA yield and fragment size vary significantly. They also compared three blood collection protocols using plasma samples from 23 healthy volunteers (EDTA tubes processed within one hour and Cell-free DNA Blood Collection Tubes processed within 24 and 72 hours) and found no significant differences in cfDNA yield, fragment size and background noise between these protocols. In 219 clinical samples, cfDNA fragments were shorter in plasma samples processed immediately after venipuncture compared to archived samples, suggesting contribution of background DNA by lysed peripheral blood cells.
Muhammed Murtaza, MD, PhD, the senior author of the study, said, “In order for us to rely on sequencing results and evidence of cancer mutations from these samples and to make valid recommendations for treating physicians, we must ensure they have been collected and processed appropriately. We developed this new quality-control assay to ensure we can confirm reliability using a very small volume of a patient’s blood sample.” The study was published on May 9, 2018, in the journal Scientific Reports.
Related Links:
Translational Genomics Research Institute
Latest Molecular Diagnostics News
- POC Diagnostic Platform Combines Immunoassay and Molecular Testing
- Innovative Test Accurately Evaluates Liver Fibrosis Severity in Just 18 Minutes
- Single Blood Test Could Detect Different Types of Cancer at Early Stages
- POC Oral Swab Test to Increase Chances of Pregnancy in IVF
- Microbial Cell-Free DNA Test Accurately Identifies Pathogens Causing Pneumonia and Other Lung Infections
- Non-Biopsy Approach to Transform Adult Celiac Disease Diagnoses
- Groundbreaking Molecular Diagnostic Test Accurately Diagnoses Major Genetic Cause of COPD
- First-in-Class Diagnostic Blood Test Detects Axial Spondyloarthritis
- New Molecular Label to Help Develop Simpler and Faster Tuberculosis Tests
- Biomarker Discovery Paves Way for Blood Tests to Detect and Treat Osteoarthritis
- Liquid Biopsy Assay Detects Recurrence in CRC Patients Prior to Imaging
- Ultra Fast Synovial Fluid Test Diagnoses Osteoarthritis and Rheumatoid Arthritis In 10 Minutes
- Genetic-Based Tool Predicts Survival Outcomes of Pancreatic Cancer Patients
- Urine Test Diagnoses Early-Stage Prostate Cancer
- New Genetic Tool Analyzes Umbilical Cord Blood to Predict Future Disease
- Spinal Fluid Biomarker for Parkinson’s Disease Offers Early and Accurate Diagnosis
Channels
Clinical Chemistry
view channel
AI-Powered Blood Test Accurately Detects Ovarian Cancer
Ovarian cancer ranks as the fifth leading cause of cancer-related deaths in women, largely due to late-stage diagnoses. Although over 90% of women exhibit symptoms in Stage I, only 20% are diagnosed in... Read more
Automated Decentralized cfDNA NGS Assay Identifies Alterations in Advanced Solid Tumors
Current circulating cell-free DNA (cfDNA) assays are typically centralized, requiring specialized handling and transportation of samples. Introducing a flexible, decentralized sequencing system at the... Read moreMass Spectrometry Detects Bacteria Without Time-Consuming Isolation and Multiplication
Speed and accuracy are essential when diagnosing diseases. Traditionally, diagnosing bacterial infections involves the labor-intensive process of isolating pathogens and cultivating bacterial cultures,... Read more
First Comprehensive Syphilis Test to Definitively Diagnose Active Infection In 10 Minutes
In the United States, syphilis cases have surged by nearly 80% from 2018 to 2023, with 209,253 cases recorded in the most recent year of data. Syphilis, which can be transmitted sexually or from mother... Read moreHematology
view channel
First Point-of-Care Heparin Monitoring Test Provides Results in Under 15 Minutes
Heparin dosing requires careful management to avoid both bleeding and clotting complications. In high-risk situations like extracorporeal membrane oxygenation (ECMO), mortality rates can reach about 50%,... Read more
New Scoring System Predicts Risk of Developing Cancer from Common Blood Disorder
Clonal cytopenia of undetermined significance (CCUS) is a blood disorder commonly found in older adults, characterized by mutations in blood cells and a low blood count, but without any obvious cause or... Read moreImmunology
view channel
Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer
Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more
Machine Learning-Enabled Blood Test Predicts Immunotherapy Response in Lymphoma Patients
Chimeric antigen receptor (CAR) T-cell therapy has emerged as one of the most promising recent developments in the treatment of blood cancers. However, over half of non-Hodgkin lymphoma (NHL) patients... Read moreMicrobiology
view channel
New Blood Test Detects Up to Five Infectious Diseases at POC
Researchers have developed a prototype flow-through assay capable of detecting up to five different infections, with results that can be quickly analyzed and transmitted via a specialized smartphone app.... Read more
Molecular Stool Test Shows Potential for Diagnosing TB in Adults with HIV
Tuberculosis (TB), caused by the bacterium Mycobacterium tuberculosis, led to 1.25 million deaths in 2023, with 13% of those occurring in people living with HIV. The current primary diagnostic method for... Read morePathology
view channel
Groundbreaking Chest Pain Triage Algorithm to Transform Cardiac Care
Cardiovascular disease is responsible for a third of all deaths worldwide, and chest pain is the second most common reason for emergency department (ED) visits. With EDs often being some of the busiest... Read more
AI-Based Liquid Biopsy Approach to Revolutionize Brain Cancer Detection
Detecting brain cancers remains extremely challenging, with many patients only receiving a diagnosis at later stages after symptoms like headaches, seizures, or cognitive issues appear. Late-stage diagnoses... Read moreTechnology
view channel
Advanced Predictive Algorithms Identify Patients Having Undiagnosed Cancer
Two newly developed advanced predictive algorithms leverage a person’s health conditions and basic blood test results to accurately predict the likelihood of having an undiagnosed cancer, including ch... Read more
Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses
Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more
Disposable Microchip Technology Could Selectively Detect HIV in Whole Blood Samples
As of the end of 2023, approximately 40 million people globally were living with HIV, and around 630,000 individuals died from AIDS-related illnesses that same year. Despite a substantial decline in deaths... Read more
Pain-On-A-Chip Microfluidic Device Determines Types of Chronic Pain from Blood Samples
Chronic pain is a widespread condition that remains difficult to manage, and existing clinical methods for its treatment rely largely on self-reporting, which can be subjective and especially problematic... Read moreIndustry
view channel
Qiagen Acquires NGS Analysis Software Company Genoox
QIAGEN (Venlo, the Netherlands) has signed a definitive agreement to acquire Genoox (Tel Aviv, Israel), a provider of artificial intelligence (AI)-powered software that enables clinical labs to scale and... Read more
Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions
Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Grifols and Tecan’s IBL Collaborate on Advanced Biomarker Panels
Grifols (Barcelona, Spain), one of the world’s leading producers of plasma-derived medicines and innovative diagnostic solutions, is expanding its offer in clinical diagnostics through a strategic partnership... Read more