We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Nano-Sized Sensor Detects Prion Proteins

By Biotechdaily staff writers
Posted on 03 Mar 2008
A nano-sized sensor detects record low levels of the deadly prion proteins that cause mad cow disease and other so-called prion diseases. The sensor, which detects binding of prion proteins by detecting frequency changes of a micromechanical oscillator, could lead to a reliable blood test for prion diseases in both animals and humans.

Prions are infectious proteins that are believed to cause deadly nerve-damaging diseases such as mad cow disease in cattle, scrapie in sheep, and a human form of mad cow disease called variant Creutzfeldt-Jakob disease. Conventional tests are designed to detect the proteins only upon autopsy, and the tests are time-consuming and unreliable.

In a new study, Harold G. Craighead, Ph.D., from Cornell University (Ithaca, NY, USA) and colleagues described a high-tech, nano-sized device called a nanomechanical resonator array. The device includes a silicon sensor, which resembles a tiny tuning fork, which changes vibrational resonant frequency when prions bind. Its vibration patterns are then measured by a special detector.

The detection system was based on arrayed resonant sensors using secondary mass labeling. With the use of antibodies as secondary mass labels 2 µg/ml concentrations of prion protein (PrP) were detected, while the addition of nanoparticle mass labels improved the detection limit by three orders of magnitude to 2 ng/mL. Owing to the high sensitivity of resonator-based detection systems, the investigators of the study claimed that they could be suitably applied to develop antemortem tests to directly detect PrP in body fluids.

The study appeared online in the February 2008 issue of the American Chemical Society's journal Analytical Chemistry.


Related Links:
Cornell University

New
Gold Member
Aspiration System
VACUSAFE
POC Helicobacter Pylori Test Kit
Hepy Urease Test
New
Automated Clinical Chemistry Analyzer
Envoy 500+
New
Repetitive Pipette
VWR® Stepper Pro

Latest BioResearch News

Single-Cell Method Measures RNA and Proteins to Reveal Immune Responses
03 Mar 2008  |   BioResearch

Study Links Midlife Vitamin D to Lower Tau in Alzheimer's
03 Mar 2008  |   BioResearch

International Consensus Standardizes Tumor Microbiota Detection and Reporting
03 Mar 2008  |   BioResearch