We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Lack of Autoantibodies Against Related Proteins in Collagenous Colitis

By LabMedica International staff writers
Posted on 21 Jun 2022
Print article
Image: Histological features of collagenous colitis (Photo courtesy of Michael Bonert, MD, FRCPC)
Image: Histological features of collagenous colitis (Photo courtesy of Michael Bonert, MD, FRCPC)

Collagenous colitis (CC) is an inflammatory disorder in the colonic mucosa that predominantly affects elderly women and causes chronic, non-bloody diarrhea with normal or close to normal endoscopic findings.

The histological criteria for CC are a thickened sub-epithelial collagen layer (> 10 µm) in the extracellular matrix (ECM) of the mucosa, epithelial damage and presence of an inflammatory infiltrate in the lamina propria. CC shares many of the characteristics found in autoimmune diseases, but no autoantibodies have been identified. In CC, an imbalance in collagen turnover is evident.

Gastroenterologists at the Skåne University Hospital (Malmö, Sweden) included in a study, 66 women with CC. The mean age at inclusion was 60 years (range 31–74 years) and mean age at diagnosis was 55 years (range 28–69 years). The size of the control groups differed, but they were selected from the same cohort consisting of 100 healthy female blood donors. The mean age of the total control group was 41.7 years (range 19–69).

In-house enzyme-linked immunosorbent assays (ELISAs) were set up for analysis of anti-IgM and IgG antibodies against collagen type III (Col III and IV). Analyses of antibodies against matrix metalloproteinase-9 (MMP-9 and Tenascin-C (TNC) were conducted by in-house ELISAs and another in-house ELISA was set up for analysis of IgM and IgG antibodies against tissue inhibitors of metalloproteinase (TIMP-1). Anti-Saccharomyces cerevisiae antibodies (ASCA) IgG were analyzed by a fluorescent enzyme immunoassay method (FEIA) for which the reference value is set > 10 U/mL (Orgentec Diagnostika, Mainz, Germany). Thyroid peroxidase (TPO) antibodies were analyzed by a chemiluminescence enzyme immunological method (Siemens Healthcare GmbH, Erlangen, Germany).

The investigators reported that there was no difference in prevalence of these collage-associated autoantibodies between CC patients and controls. Sixteen patients expressed one type of autoantibody, whereas two patients expressed two different types. The mean disease duration was significantly lower in the subjects who expressed collagen-associated autoantibodies (3.7 years; range 1–14), compared to those who did not (6.4 years; range 1–22). The presence of autoantibodies against TPO and ASCA was slightly increased compared to controls, but not statistically significant. Increased levels of total IgE were equally present in the CC patients and the control group, and there was no correlation between total IgE-positivity and presence of any autoantibodies.

The authors concluded that no increased presence of the investigated antibodies could be found in the present study of CC. Neither could antibodies against ASCA or TPO, or elevated levels of IgE, be found. Consequently, no association was found between CC and these proteins, even though this may not be generalizable to other compounds in the collagen layer. The study was published on June 6, 2022 in the journal BMC Immunology.

Related Links:
Skåne University Hospital 
Orgentec Diagnostika 
Siemens Healthcare GmbH 

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The revolutionary autonomous blood draw technology is witnessing growing demands (Photo courtesy of Vitestro)

Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing

Blood drawing is performed billions of times each year worldwide, playing a critical role in diagnostic procedures. Despite its importance, clinical laboratories are dealing with significant staff shortages,... Read more