We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Leukocyte Differential on Hematology Analyzer Compared and Evaluated

By LabMedica International staff writers
Posted on 21 Jun 2021
Print article
Image: The Celltac G fully-automatic hematology analyzer with 33 parameters (Photo courtesy of Nihon Kohden)
Image: The Celltac G fully-automatic hematology analyzer with 33 parameters (Photo courtesy of Nihon Kohden)
A complete blood count (CBC), also known as a full blood count (FBC), is a set of medical laboratory tests that provide information about the cells in a person's blood. The CBC indicates the counts of white blood cells, red blood cells and platelets, the concentration of hemoglobin, and the hematocrit (the volume percentage of red blood cells).

Different hematology analyzer models use various principles to measure the complete blood count (CBC) and leukocyte differential for routine tests in clinical laboratories. The accuracy performance of a hematology analyzer is evaluated using the manual differential leukocyte (Manual-Diff) on blood wedge film (Wedge-Diff) as the traditional reference method.

Clinical Laboratorians at the Kindai University Hospital (Osakasayama, Japan) selected for method comparison, 598 clinical samples and 46 healthy volunteer samples. All samples were collected in tubes containing K2-EDTA. The blood collection tubes, blood collection procedure, and mixing procedure were according to described methods. For method comparison between the three analyzers, 388 clinical samples were used. Blood films were stained with May-Giemsa.

The automated hematology analyzer Celltac G (Nihon Kohden, Tokyo, Japan) was designed to improve leukocyte differential performance. The two comparative hematology analyzers (CAAs) used were XN-9000 (Sysmex, Kobe, Japan) and CELL-DYN Sapphire (Abbott Diagnostics, Santa Clara, CA, USA). In manual differential, two kinds of automated slide makers were used: the Sysmex SP-10 for wedge technique and SPINNER-2000 (Lion-Power, Komatsu, Japan) for spinner technique. The immunophenotypic leukocyte differential reference method (FCM-Ref) was selected, and a flow cytometer Navios (Beckman-Coulter, Indianapolis, IN, USA) was used.

The investigators reported that the Celltac G showed sufficient comparability with the CAAs for each leukocyte differential counting value up to 40.87 × 109/L, and sufficient comparability with FCM-Ref for each leukocyte differential percentage at 0.4–78.5. The identification ratio of the FCM-Ref in CD45-positive cells was 99.7% (99.4% to 99.8%). Differences were found between FCM-Ref/Celltac G/XN-9000/Spinner-Diff and Wedge-Diff for monocytes and neutrophils. The appearance ratio of smudge cells on wedge and spinner film was 12.5% and 0.5%.

The authors concluded that the Celltac G hematology analyzer's leukocyte differential showed adequate accuracy compared with two comparative hematology analyzers, reference flow cytometry method, and two manual methods and was considered suitable for clinical use. The study was published on June 12, 2021 in the Journal of Clinical Laboratory Analysis.

Related Links:
Kindai University Hospital
Nihon Kohden
Sysmex
Abbott Diagnostics
Lion-Power
Beckman-Coulter


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The revolutionary autonomous blood draw technology is witnessing growing demands (Photo courtesy of Vitestro)

Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing

Blood drawing is performed billions of times each year worldwide, playing a critical role in diagnostic procedures. Despite its importance, clinical laboratories are dealing with significant staff shortages,... Read more