We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Immunoassay Developed for Quantitative Detection of Serum Interleukin‐6

By LabMedica International staff writers
Posted on 07 Apr 2021
Print article
Image: The quantum dot (QD)‐based fluorescence lateral flow immunoassay (LFIA) strip can rapidly and accurately detect IL‐6 levels at different concentrations (Photo courtesy of University of South China)
Image: The quantum dot (QD)‐based fluorescence lateral flow immunoassay (LFIA) strip can rapidly and accurately detect IL‐6 levels at different concentrations (Photo courtesy of University of South China)
Interleukin‐6 (IL‐6) is a multifunctional protein and is primarily produced by macrophages, monocytes, fibroblasts, and T lymphocytes, and plays important roles in immune regulation, hematopoiesis, inflammation, and tumorigenesis.

IL‐6 has shown the highest value in the diagnosis of sepsis compared with procalcitonin (PCT) and C‐reactive protein (CRP), which are also important biomarkers of infection. Traditional IL‐6 detection methods include chemiluminescence immunoassays (CLIA), enzyme‐linked immunosorbent assays (ELISA) and electrochemiluminescence immunoassays (ECLIA).

Medical Scientists at the Second Affiliated Hospital of University of South China (Hengyang, China) developed a quantum dot (QD)‐based fluorescence lateral flow immunoassay (LFIA) strip that can rapidly and accurately detect IL‐6 levels. The QD‐based LFIA strips were fabricated by conjugating cadmium selenide/zinc sulfide (CdSe/ZnS) QDs to the IL‐6 antibody. The strips were made of nitrocellulose (NC) membranes, semi‐rigid polyvinylchloride (PVC) sheets, and polyester fiber. The IL‐6 CLIA kits were from Beckman Coulter (Pasadena, CA, USA).

The fluorescence intensity of the test (T) line and the control (C) line on the strip were detected using the self‐designed KF‐Q001‐A fluorescence immunoassay analyzer (Kingfocus Biomedical Engineering Co., Ltd, Shenzhen City, China). The QDs and antibodies were dispensed onto the strip using a piece of three‐dimensional gold‐spraying equipment. IL‐6 CLIA detection was performed on the Beckman Coulter Dxl800 instrument. A total of 200 human serum samples were obtained from a local hospital, The IL‐6 concentrations of these samples ranged from 0 to 580.42 ng/mL. The samples were detected using the strip and the Beckman IL‐6 CLIA kit within two hours of each other.

The investigators reported that the test strip's linear range was 10–4,000 pg/mL, with a linear correlation coefficient of R2 ≥ 0.959. The sensitivity of the test strip was 1.995 pg/mL. The recovery rate was 95.72%–102.63%, indicating satisfying accuracy. The coefficient of variation (CV) of the intra‐assay was 2.148%–3.903%, while the inter‐assay was 2.412%–5.293%, verifying the strip's high precision. The cross‐reaction rates with various interleukins (IL‐1α, IL‐1β, IL‐2, IL‐4, and IL‐8) and interferon‐γ (IFN‐γ) were all less than 0.1%.

The authors concluded that they had successfully established a QD‐based LFIA method for rapid and accurate detection of human serum IL‐6, providing a more simple, robust, and economic point-of-care technology (POCT) for IL‐6 quantification, which is of great value for the early detection and treatment of sepsis and related disorders. The study was published on March 24, 2021 in the Journal of Clinical Laboratory Analysis.

Related Links:
Second Affiliated Hospital of University of South China
Beckman Coulter
Kingfocus Biomedical Engineering Co., Ltd


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The revolutionary autonomous blood draw technology is witnessing growing demands (Photo courtesy of Vitestro)

Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing

Blood drawing is performed billions of times each year worldwide, playing a critical role in diagnostic procedures. Despite its importance, clinical laboratories are dealing with significant staff shortages,... Read more