Paper Diagnostic Directly Measures Fibrinogen in Whole Blood
By LabMedica International staff writers Posted on 10 Nov 2020 |
Image: Fibrinogen Test: people with low fibrinogen levels show a rapid movement of blood up the device (Photo courtesy of Monash University).
Fibrinogen is a protein found in blood that is needed for clotting. When a patient experiences traumatic injury, such as a serious car accident, or major surgery and childbirth complications, fibrinogen is required in their blood to prevent major hemorrhaging and death from blood loss.
Typically, heavily bleeding patients must be transported to a hospital or emergency center where they undergo diagnostic tests before being treated. These tests are time consuming and costly as they require expensive equipment, specialized or trained personnel and can take up to half an hour. More than 20% of major trauma patients have hyperfibrinogenemia.
Chemical Engineers at Monash University (Clayton, Australia) developed a handheld fibrinogen diagnostic device that works with whole blood. The test works by placing a pre-mixed droplet of a blood sample and an enzyme solution onto a solid surface, allowing it to clot, and then dropping a paper strip on top. The further that blood moves down the strip of paper, the lower the fibrinogen concentration. The diagnostic can work with a variety of blood conditions. Furthermore, diluting blood samples not only increases the test's sensitivity, but also eliminates the effect of interfering substances in the blood.
The further that blood moves down the strip, the lower the fibrinogen concentration. The diagnostic can easily measure plasma fibrinogen concentrations below 1.6 g/L for blood samples with hematocrits between 40 and 50%. The test can be completed in 3 to 4 minutes, making it suitable for diagnosing early hypofibrinogenemia and allowing for fibrinogen replacement therapy in critically bleeding patients.
Gil Garnier, PhD, a Professor of Chemical Engineering and senior author of the study, said, “This diagnostic will allow emergency doctors and paramedics to quickly and accurately diagnose low levels of fibrinogen in patients, giving them faster access to life-saving treatment to stop critical bleeding. When a patient is bleeding heavily and has received several blood transfusions, their levels of fibrinogen drop. Even after dozens of transfusions, patients keep bleeding. What they need is an injection of fibrinogen. However, if patients receive too much fibrinogen, they can also die.” The study was published on October 23, 2020 in the journal ACS Sensors.
Related Links:
Monash University
Typically, heavily bleeding patients must be transported to a hospital or emergency center where they undergo diagnostic tests before being treated. These tests are time consuming and costly as they require expensive equipment, specialized or trained personnel and can take up to half an hour. More than 20% of major trauma patients have hyperfibrinogenemia.
Chemical Engineers at Monash University (Clayton, Australia) developed a handheld fibrinogen diagnostic device that works with whole blood. The test works by placing a pre-mixed droplet of a blood sample and an enzyme solution onto a solid surface, allowing it to clot, and then dropping a paper strip on top. The further that blood moves down the strip of paper, the lower the fibrinogen concentration. The diagnostic can work with a variety of blood conditions. Furthermore, diluting blood samples not only increases the test's sensitivity, but also eliminates the effect of interfering substances in the blood.
The further that blood moves down the strip, the lower the fibrinogen concentration. The diagnostic can easily measure plasma fibrinogen concentrations below 1.6 g/L for blood samples with hematocrits between 40 and 50%. The test can be completed in 3 to 4 minutes, making it suitable for diagnosing early hypofibrinogenemia and allowing for fibrinogen replacement therapy in critically bleeding patients.
Gil Garnier, PhD, a Professor of Chemical Engineering and senior author of the study, said, “This diagnostic will allow emergency doctors and paramedics to quickly and accurately diagnose low levels of fibrinogen in patients, giving them faster access to life-saving treatment to stop critical bleeding. When a patient is bleeding heavily and has received several blood transfusions, their levels of fibrinogen drop. Even after dozens of transfusions, patients keep bleeding. What they need is an injection of fibrinogen. However, if patients receive too much fibrinogen, they can also die.” The study was published on October 23, 2020 in the journal ACS Sensors.
Related Links:
Monash University
Latest Technology News
- New Diagnostic System Achieves PCR Testing Accuracy
- DNA Biosensor Enables Early Diagnosis of Cervical Cancer
- Self-Heating Microfluidic Devices Can Detect Diseases in Tiny Blood or Fluid Samples
- Breakthrough in Diagnostic Technology Could Make On-The-Spot Testing Widely Accessible
- First of Its Kind Technology Detects Glucose in Human Saliva
- Electrochemical Device Identifies People at Higher Risk for Osteoporosis Using Single Blood Drop
- Novel Noninvasive Test Detects Malaria Infection without Blood Sample
- Portable Optofluidic Sensing Devices Could Simultaneously Perform Variety of Medical Tests
- Point-of-Care Software Solution Helps Manage Disparate POCT Scenarios across Patient Testing Locations
- Electronic Biosensor Detects Biomarkers in Whole Blood Samples without Addition of Reagents
- Breakthrough Test Detects Biological Markers Related to Wider Variety of Cancers
- Rapid POC Sensing Kit to Determine Gut Health from Blood Serum and Stool Samples
- Device Converts Smartphone into Fluorescence Microscope for Just USD 50
- Wi-Fi Enabled Handheld Tube Reader Designed for Easy Portability