Urea Dissociation Tests Reduces SARS-CoV-2 IgM False-Positives
By LabMedica International staff writers Posted on 28 Apr 2020 |
Image: The PHOMO Microplate Reader: the sophisticated optical design combined with the accurate plate transport system allows for high resolution scanning (29 points per well) to support agglutination assays (Photo courtesy of Autobio Diagnostics Co).
At present, the diagnosis of COVID-19 is mainly based on epidemiological history inquiry, laboratory testing, and chest radiology examination. Among these examinations, the detection of nucleic acid from SARS-CoV-2 is the direct evidence for COVID-19 diagnosis.
The detection of serum-specific IgM and IgG, especially the former, is routinely used in clinical laboratories to evaluate the acute phase infection of pathogens in the serum. In many infections, IgM can be detected as early as one week after infection. When the level of IgM reaches the detection limit of the assay kit, the detection of IgM can avoid false-negative results owing to sampling.
Medical Laboratory Scientists at the Affiliated Hospital of North Sichuan Medical College (Nanchong, P.R. China) used gold immunochromatography assay (GICA) and enzyme-linked immunosorbent assay (ELISA) to detect SARS-CoV-2 IgM in 86 serum samples, including five influenza A virus (Flu A) IgM-positive sera, five influenza B virus (Flu B) IgM-positive sera, five Mycoplasma pneumoniae IgM-positive sera, five Legionella pneumophila IgM-positive sera, six sera of HIV infection patients, 36 rheumatoid factor IgM (RF-IgM)-positive sera, five sera from hypertensive patients, five sera from diabetes mellitus patients, and 14 sera from novel coronavirus infection disease (COVID-19) patients.
The interference factors causing false-positive reactivity in the two methods were analyzed, and the urea dissociation test was employed to dissociate the SARS-CoV-2 IgM-positive serum using the best dissociation concentration. The IgM against Flu A and B, M. pneumoniae, and L. pneumophila were detected by indirect immunofluorescence assay (Respiratory tract 8 joint detection kit, EUROIMMUN, Inc., Lübeck, Germany). Rheumatoid Factor (RF-IgM) was detected by rate nephelometry assay (IMMAGE800, Beckman Coulter, Inc., Brea, CA, USA). HIV combi PT was detected by electrochemiluminescence assay (Cobas E602, Roche, Mannheim, Germany).
GICA and ELISA were used for SARS-CoV-2 IgM detection (kit provided by Beijing Hotgen Biotechnology Co., Beijing, China). Optical density in ELISA plates was measured using a PHOMO Microplate Reader (Autobio Diagnostics Co., Zhengzhou, China). Urea dissociation tests of GICA and ELISA were also performed.
The team reported that both GICA and ELISA detected positive SARS-CoV-2 IgM in 22 middle-high level RF-IgM-positive sera and in all the 14 sera from the patients with COVID-19 patients. The other 50 sera were negative. When urea dissociation concentration was 6 mol/L, SARS-CoV-2 IgM was positive in one middle-high level RF-IgM-positive sera and in the 14 COVID-19 samples detected using GICA. When urea dissociation concentration was 4 mol/L and the avidity index (AI) lower than 0.371 was set to negative, test results were positive for SARS-CoV-2 in 3 middle-high level RF-IgM-positive sera, as well as the 14 COVID-19 sera detected using ELISA.
The authors concluded that middle-high level of RF-IgM could lead to false-positive reactivity of SARS-CoV-2 IgM detected using GICA and ELISA, and urea dissociation tests would be helpful in reducing false-positive results of SARS-CoV-2 IgM. The study was published on April 10, 2020 in the Journal of Clinical Microbiology.
The detection of serum-specific IgM and IgG, especially the former, is routinely used in clinical laboratories to evaluate the acute phase infection of pathogens in the serum. In many infections, IgM can be detected as early as one week after infection. When the level of IgM reaches the detection limit of the assay kit, the detection of IgM can avoid false-negative results owing to sampling.
Medical Laboratory Scientists at the Affiliated Hospital of North Sichuan Medical College (Nanchong, P.R. China) used gold immunochromatography assay (GICA) and enzyme-linked immunosorbent assay (ELISA) to detect SARS-CoV-2 IgM in 86 serum samples, including five influenza A virus (Flu A) IgM-positive sera, five influenza B virus (Flu B) IgM-positive sera, five Mycoplasma pneumoniae IgM-positive sera, five Legionella pneumophila IgM-positive sera, six sera of HIV infection patients, 36 rheumatoid factor IgM (RF-IgM)-positive sera, five sera from hypertensive patients, five sera from diabetes mellitus patients, and 14 sera from novel coronavirus infection disease (COVID-19) patients.
The interference factors causing false-positive reactivity in the two methods were analyzed, and the urea dissociation test was employed to dissociate the SARS-CoV-2 IgM-positive serum using the best dissociation concentration. The IgM against Flu A and B, M. pneumoniae, and L. pneumophila were detected by indirect immunofluorescence assay (Respiratory tract 8 joint detection kit, EUROIMMUN, Inc., Lübeck, Germany). Rheumatoid Factor (RF-IgM) was detected by rate nephelometry assay (IMMAGE800, Beckman Coulter, Inc., Brea, CA, USA). HIV combi PT was detected by electrochemiluminescence assay (Cobas E602, Roche, Mannheim, Germany).
GICA and ELISA were used for SARS-CoV-2 IgM detection (kit provided by Beijing Hotgen Biotechnology Co., Beijing, China). Optical density in ELISA plates was measured using a PHOMO Microplate Reader (Autobio Diagnostics Co., Zhengzhou, China). Urea dissociation tests of GICA and ELISA were also performed.
The team reported that both GICA and ELISA detected positive SARS-CoV-2 IgM in 22 middle-high level RF-IgM-positive sera and in all the 14 sera from the patients with COVID-19 patients. The other 50 sera were negative. When urea dissociation concentration was 6 mol/L, SARS-CoV-2 IgM was positive in one middle-high level RF-IgM-positive sera and in the 14 COVID-19 samples detected using GICA. When urea dissociation concentration was 4 mol/L and the avidity index (AI) lower than 0.371 was set to negative, test results were positive for SARS-CoV-2 in 3 middle-high level RF-IgM-positive sera, as well as the 14 COVID-19 sera detected using ELISA.
The authors concluded that middle-high level of RF-IgM could lead to false-positive reactivity of SARS-CoV-2 IgM detected using GICA and ELISA, and urea dissociation tests would be helpful in reducing false-positive results of SARS-CoV-2 IgM. The study was published on April 10, 2020 in the Journal of Clinical Microbiology.
Latest Immunology News
- Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies
- AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell
- Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment
- Testing Method Could Help More Patients Receive Right Cancer Treatment
- Groundbreaking Test Monitors Radiation Therapy Toxicity in Cancer Patients
- State-Of-The Art Techniques to Investigate Immune Response in Deadly Strep A Infections
- Novel Immunoassays Enable Early Diagnosis of Antiphospholipid Syndrome
- New Test Could Predict Immunotherapy Success for Broader Range Of Cancers
- Simple Blood Protein Tests Predict CAR T Outcomes for Lymphoma Patients
- Cell Sorter Chip Technology to Pave Way for Immune Profiling at POC
- Chip Monitors Cancer Cells in Blood Samples to Assess Treatment Effectiveness
- Automated Immunohematology Approaches Can Resolve Transplant Incompatibility
- AI Leverages Tumor Genetics to Predict Patient Response to Chemotherapy
- World’s First Portable, Non-Invasive WBC Monitoring Device to Eliminate Need for Blood Draw
- Predictive T-Cell Test Detects Immune Response to Viruses Even Before Antibodies Form
- Single Blood Draw to Detect Immune Cells Present Months before Flu Infection Can Predict Symptoms