By LabMedica International staff writers
Posted on 26 Oct 2019
Print article
Image: The cobas e 601 is a fully automated analyzer that uses a patented electrochemiluminescence (ECL) technology for immunoassay analysis (Photo courtesy of Roche Diagnostics).
Image: The cobas e 601 is a fully automated analyzer that uses a patented electrochemiluminescence (ECL) technology for immunoassay analysis (Photo courtesy of Roche Diagnostics).
Interleukin‐6 (IL‐6), a pleiotropic cytokine, is released by a variety of cell types such as immune cells, endothelial cells, and even certain tumor cells. It is a classic proinflammation cytokine which exhibits broad‐ranging biological activities by involved in the intricate cellular communication.

Pre‐analytical variables for the test include blood collection tubes, specimen storage temperature and time, plasma or serum separation, and pretreatment steps. Studies have shown pre‐analytical handling steps can influence sample quality and analytical results. The fact that the half‐life of IL‐6 is short, degradation and production may occur simultaneously during storage under unseparated condition.

Medical Laboratory Scientists at the Southern Medical University (Guangzhou, China) collected EDTA plasma and serum samples from 45 healthy individuals. The participants were divided into three groups to perform different handling procedures. Different centrifugal timing, storage temperature, and time were executed on the samples. All samples were centrifuged at 1760 ×g for 15 minutes, but centrifugal timing selection was different in three groups. Serum and plasma IL‐6 levels were assayed through the electrochemiluminescence (ECLIA) method on Cobas e 601 analyzer. The changed trends of IL‐6 levels were analyzed.

The team reported that at baseline, while the paired plasma and serum IL‐6 values had a good correlation, the plasma levels were higher than serum. In general, the unseparated EDTA plasma kept steady with time. With the increase in storage temperature and time, a more pronounced rise in unseparated serum IL‐6 was observed. Nevertheless, the samples in the group, which was centrifuged and separated immediately kept stable after a different temperature and longtime storage.

The authors concluded that factors that affect changes in cytokine levels are various and incorrect sample handling procedures may result in false results. In general, unseparated EDTA plasma can keep IL‐6 steady for up to 24 hours. In not refrigerated conditions, unseparated serum is recommended to measure IL‐6 as soon as possible. Otherwise, the serum separation should be done. The study was published in the September 2019 issue of the Journal of Clinical Laboratory Analysis.

Related Links:
Southern Medical University

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Pathology

view channel
Image: Comparison of traditional histopathology imaging vs. PARS raw data (Photo courtesy of University of Waterloo)

AI-Powered Digital Imaging System to Revolutionize Cancer Diagnosis

The process of biopsy is important for confirming the presence of cancer. In the conventional histopathology technique, tissue is excised, sliced, stained, mounted on slides, and examined under a microscope... Read more