We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Urinary Biomarkers for Tuberculosis Explored

By LabMedica International staff writers
Posted on 25 Dec 2018
Print article
Image: The Simoa HD-1 Analyzer is a fully automated instrument for running immunoassays (Photo courtesy of Quanterix).
Image: The Simoa HD-1 Analyzer is a fully automated instrument for running immunoassays (Photo courtesy of Quanterix).
The gold standard for tuberculosis (TB) diagnosis is the isolation in culture of Mycobacterium tuberculosis in biological samples. However, culture is time consuming and does not accomplish the need of quickly and properly starting treatment, it is not always feasible in extra-pulmonary TB and it is difficult to carry out in resource-limited settings.

To predict the efficacy of anti-TB therapy, sputum conversion after two months of specific treatment is widely used in culture positive TB cases, though simpler and more rapid diagnostic assays would be useful. Therefore, identification of new biomarkers for TB diagnosis and therapy monitoring will provide powerful tools to defeat TB.

In chronic hepatitis, patients not responding to interferon/ribavirin treatment had high levels of an antagonist form of Interferon gamma-induced protein 10 (IP-10). Recently, antagonist IP-10 has been shown to be involved also in TB pathogenesis.

A team of scientists led by the Lazzaro Spallanzani National Institute for Infectious Diseases (Rome Italy) enrolled 33 patients with active TB, 11 patients with pneumonia (either bacterial or viral) and 17 healthy donors (HD) between November 2014 and December 2016. Due to technical problems the analysis was performed on 58 subjects: 32 patients with active TB, 10 patients with pneumonia and 16 HD.

Spot morning urine samples were collected, then transferred to protease-inhibitor tubes, aliquoted in 1 mL tubes and stored at −80 °C until use. Thawed urine samples were centrifuged at 10,000 g for 10 minutes at 4 °C, diluted 1:3 and tested for all forms of IP-10 (total IP-10), agonist IP-10 (long IP-10, 1-77 CXCL10) and antagonist IP-10 (short IP-10, 3-77 CXCL10) using in-house SIMOA ultrasensitive digital enzyme-linked immunosorbent assay (ELISA). Creatinine was measured to normalize IP-10 levels using a BioAssay Systems Quantichrom photometric assay and IP-10 levels were expressed as mg/g.

The scientists found that patients with active TB had significantly higher levels of total and agonist IP-10 at baseline compared to HD; conversely, no differences were observed between IP-10 levels in active TB versus pneumonia. Moreover, in active TB a decline of total urine IP-10 was observed at therapy completion; agonist/antagonist forms reflected this decline although their differences were not statistically significant.

The authors concluded that they showed for the first time that agonist/antagonist IP-10 forms are measurable in urine. IP-10 levels associate with TB and pneumonia disease, suggesting their association with acute inflammation. Further studies are needed to assess their role to monitor TB treatment efficacy. The study was published in the January 2019 issue of the International Journal of Infectious Diseases.

Related Links:
Lazzaro Spallanzani National Institute for Infectious Diseases

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: The fastGEN BCR::ABL1 Cancer kit offers a way to personalize treatment strategies for leukemia (Photo courtesy of BioVendor MDx)

First of Its Kind NGS Assay for Precise Detection of BCR::ABL1 Fusion Gene to Enable Personalized Leukemia Treatment

The BCR::ABL1 fusion gene plays a key role in the pathogenesis of several blood cancers, particularly chronic myeloid leukemia (CML). This gene results from a chromosomal translocation that causes constitutive... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The new method is quick and easy, and can also be used by non-medical personnel. (Photo courtesy of Zoratto et al. Advanced Science 2024, edited)

New Blood Test Device Modeled on Leeches to Help Diagnose Malaria

Many individuals have a fear of needles, making the experience of having blood drawn from their arm particularly distressing. An alternative method involves taking blood from the fingertip or earlobe,... Read more