Methods Discriminate Dengue Severity during Acute Infection
By LabMedica International staff writers Posted on 03 Sep 2018 |
Image: The Panbio Dengue Duo Cassette can detect the high levels of IgG characteristic of secondary infections and IgM levels associated with primary dengue with high sensitivity and specificity (Photo courtesy of Alere).
Dengue is the most widely distributed mosquito-borne human viral disease and represents a major public health burden globally. An estimated 390 million infections occur each year, of which around 100 million are symptomatic.
Although prior infection with another viral serotype, such as secondary dengue, is known to be an important factor influencing disease severity, current methods to determine primary versus secondary immune status during the acute illness do not consider the rapidly evolving immune response, and their accuracy has rarely been evaluated against an independent gold standard.
An international team led working at the Hospital for Tropical Diseases (Oxford University Clinical Research Unit, Ho Chi Minh City, Vietnam) enrolled 293 laboratory confirmed dengue patients aged 5 to 25 years who had registered in one of several clinical studies carried out at the Hospital for Tropical Diseases. Daily plasma samples obtained during the acute illness were assayed using the Panbio anti-dengue indirect immunoglobulin-G (IgG) enzyme-linked immunosorbent assay (ELISA), as well as in-house anti-dengue IgG and IgM capture ELISAs. Plaque reduction neutralization tests (PRNTs) were performed six months after the acute illness episode to define immune status.
The scientists reported that cut-offs derived for the various parameters demonstrated progressive change (positively or negatively) by day of illness. Using these time varying cut-offs it was possible to determine whether an infection was primary or secondary on single specimens, with acceptable performance. The model using Panbio Indirect IgG responses and including an interaction with illness day showed the best performance throughout, although with some decline in performance later in infection. Models based on in-house capture IgG levels, and the IgM/IgG ratio, also performed well, though conversely performance improved later in infection.
The authors concluded that for all assays, the best fitting models estimated a different cut-off value for different days of illness, confirming how rapidly the immune response changes during acute dengue. The optimal choice of assay will vary depending on circumstance. Although the Panbio Indirect IgG model performs best early on, the IgM/IgG capture ratio may be preferred later in the illness course. The study was published on August 7, 2018, in the journal BMC Infectious Diseases.
Related Links:
Hospital for Tropical Diseases
Although prior infection with another viral serotype, such as secondary dengue, is known to be an important factor influencing disease severity, current methods to determine primary versus secondary immune status during the acute illness do not consider the rapidly evolving immune response, and their accuracy has rarely been evaluated against an independent gold standard.
An international team led working at the Hospital for Tropical Diseases (Oxford University Clinical Research Unit, Ho Chi Minh City, Vietnam) enrolled 293 laboratory confirmed dengue patients aged 5 to 25 years who had registered in one of several clinical studies carried out at the Hospital for Tropical Diseases. Daily plasma samples obtained during the acute illness were assayed using the Panbio anti-dengue indirect immunoglobulin-G (IgG) enzyme-linked immunosorbent assay (ELISA), as well as in-house anti-dengue IgG and IgM capture ELISAs. Plaque reduction neutralization tests (PRNTs) were performed six months after the acute illness episode to define immune status.
The scientists reported that cut-offs derived for the various parameters demonstrated progressive change (positively or negatively) by day of illness. Using these time varying cut-offs it was possible to determine whether an infection was primary or secondary on single specimens, with acceptable performance. The model using Panbio Indirect IgG responses and including an interaction with illness day showed the best performance throughout, although with some decline in performance later in infection. Models based on in-house capture IgG levels, and the IgM/IgG ratio, also performed well, though conversely performance improved later in infection.
The authors concluded that for all assays, the best fitting models estimated a different cut-off value for different days of illness, confirming how rapidly the immune response changes during acute dengue. The optimal choice of assay will vary depending on circumstance. Although the Panbio Indirect IgG model performs best early on, the IgM/IgG capture ratio may be preferred later in the illness course. The study was published on August 7, 2018, in the journal BMC Infectious Diseases.
Related Links:
Hospital for Tropical Diseases
Latest Microbiology News
- New CE-Marked Hepatitis Assays to Help Diagnose Infections Earlier
- 1 Hour, Direct-From-Blood Multiplex PCR Test Identifies 95% of Sepsis-Causing Pathogens
- Mouth Bacteria Test Could Predict Colon Cancer Progression
- Unique Metabolic Signature Could Enable Sepsis Diagnosis within One Hour of Blood Collection
- Groundbreaking Diagnostic Platform Provides AST Results With Unprecedented Speed
- Simple Blood Test Combined With Personalized Risk Model Improves Sepsis Diagnosis
- Blood Analysis Predicts Sepsis and Organ Failure in Children
- TB Blood Test Could Detect Millions of Silent Spreaders
- New Blood Test Cuts Diagnosis Time for Nontuberculous Mycobacteria Infections from Months to Hours
- New Tuberculosis Test to Expand Testing Access in Low- and Middle-Income Countries
- Rapid Test Diagnoses Tropical Disease within Hours for Faster Antibiotics Treatment
- Rapid Molecular Testing Enables Faster, More Targeted Antibiotic Treatment for Pneumonia
- Rapid AST Platform Provides Targeted Therapeutic Results Days Faster Than Current Standard of Care
- New Analysis Method Detects Pathogens in Blood Faster and More Accurately by Melting DNA
- Rapid Sepsis Test Delivers Two Days Faster Results
- Portable Rapid PCR Diagnostic to Detect Gonorrhea and Antibiotic Susceptibility