We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

IgM Antibodies Improve Risk Stratification for Antiphospholipid Syndrome

By LabMedica International staff writers
Posted on 08 Aug 2018
Print article
Image: The ACL AcuStar testing analyzer offers full automation of highly sensitive immunoassays (Photo courtesy of Instrumentation Laboratory).
Image: The ACL AcuStar testing analyzer offers full automation of highly sensitive immunoassays (Photo courtesy of Instrumentation Laboratory).
The antiphospholipid syndrome (APS) is an autoimmune hypercoagulable state and is characterized by thrombosis and/or pregnancy morbidity with the persistent presence of antiphospholipid antibodies (aPL).

Laboratory criteria include aPL detection by lupus anticoagulant (LAC), anti‐β2glycoprotein I (aβ2GPI) and anti‐cardiolipin (aCL) IgG/IgM antibodies. Although all aPL have the same value in the Sydney classification criteria, the clinical and diagnostic relevance of IgM aPL in APS has been debated and data on the issue has been inconclusive.

A team of scientists collaborating with their colleagues at Maastricht University Medical Center (Maastricht, the Netherlands) analyzed data on 1,068 patients from eight participating centers in Europe. Of the patients, 259 had APS-associated thrombosis, 204 had thrombosis but were negative for APS antibodies, 122 had obstetric APS, 33 had obstetric complications but no APS antibodies, 196 had an autoimmune disease other than APD, 194 were controls referred for APS testing but for reasons other than obstetric or thrombosis, and 60 had unspecified status.

The team used four commercially available solid phase assays; the results showed that LAC, IgG, and IgM antibodies had significant odds ratios for thrombosis and/or pregnancy morbidity, regardless of the assay used. However, in general, IgG positivity is more strongly correlated with thrombosis and pregnancy morbidity than IgM positivity. LAC positivity was independently correlated with thrombosis and/or pregnancy morbidity, isolated IgM positivity (with negative LAC results) did not have a correlation on any of the assays, while isolated IgG positivity showed a correlation on two of the four platforms.

The addition of IgM to the LAC-IgG panel did add value in thrombotic and pregnancy morbidity risk stratification, improving the odds ratio on the ACL AcuStar test for pregnancy morbidity from 2.9 to 5.1 and on the QUANTA Lite ELISA test, from 4.8 to 10.3. However, assessments of patients with thrombosis and/or pregnancy morbidity showed that IgM titers were not higher in those patients compared with controls on three of the four assays. As part of the full aPL panel, aCL and aβ2GPI IgM correlate significantly with thrombosis and/or pregnancy morbidity. The data suggest that detection of LAC and IgG aPL is sufficient for the identification of APS patients. Triple positivity for the IgG, but not IgM isotype can improve risk stratification in APS patients.

Walid Chayoua, PhD, a biochemist and a co-author of the study, said, “With the current antiphospholipid panel, aCL and anti‐β2glycoprotein I IgM antibodies do not have an added valued in the diagnosis of antiphospholipid syndrome. However, aCL and anti‐β2glycoprotein I IgM positivity are of added value in risk stratification for both thrombosis and pregnancy morbidity. All aPL included in the aPL panel are significantly correlated with thrombosis and pregnancy morbidity, independent of the isotype and solid phase assay.” The study was presented at the International Society on Thrombosis and Haemostasis (ISTH) 64th Annual Scientific and Standardization Committee (SSC) Meeting, held July 18-21, 2018, in Dublin, Ireland.

Related Links:
Maastricht University Medical Center

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A network of inflammatory molecules may act as biomarker for risk of future cerebrovascular disease (Photo courtesy of 123RF)

Simple Blood Test Could Enable First Quantitative Assessments for Future Cerebrovascular Disease

Cerebral small vessel disease is a common cause of stroke and cognitive decline, particularly in the elderly. Presently, assessing the risk for cerebral vascular diseases involves using a mix of diagnostic... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more