Rapid Diagnostic Test for Malaria Compared
By LabMedica International staff writers Posted on 13 Jun 2018 |
Image: The Deki Reader is a rugged, in vitro diagnostic device for use with commercially available lateral flow immunoassays, commonly known as rapid diagnostic tests (Photo courtesy of Fio Corporation).
Malaria case management, consisting of early diagnosis and prompt effective treatment, remains a vital component of malaria control and elimination strategies. Although microscopy is a standard diagnostic tool for malaria and the gold standard, it is infrequently used because of unavailability of laboratory facilities and the absence of skilled readers in poor resource settings.
Rapid diagnostic tests (RDTs) are being advocated and used as alternative, or as an adjunct to microscopy at health facilities because they can be easily used by health workers with less training and equipment, and can be performed by non-specialists in remote settings. The RDTs provide fast test results for initiating or maintaining treatment of patients.
An international team of scientists working with the Kilimanjaro Christian Medical University College (Moshi, Tanzania) recruited a total of 1,293 among 1,423 outpatients with axillary temperature ≥ 37.5 °C, reported fever in the past 24 hours and/or other symptoms suggestive of malaria. The median age for study participants was 21 years and the majority of the participants (71.4%; 923/1293) were aged 18 to 24 years. More than two thirds (69.1%; 893/1293) of study participants were male.
In this study, the SD Bioline Malaria Antigen Pf/pan RDT that detects PfHRP2 (Plasmodium falciparum) and pLDH (pan) was used for malaria diagnosis alongside microscopy. Stained smears were examined by experienced senior microscopists. The Deki Reader (DR, Fio Corporation, Toronto, ON, Canada) provided automated sequential procedures to guide personnel on how to conduct the RDT test. After capturing an image and recognizing the brand of the RDT, the device prompts the user to remove the RDT from the device to proceed with taking blood samples from the patient.
The sensitivity of malaria rapid diagnostic test results interpreted by the Deki Reader was 94.1% and that of visual interpretation was 93.9%. The specificity of malaria rapid diagnostic test results was 71.8% and that of human interpretation was 72.0%. The positive predictive value of malaria RDT results by the Deki Reader and visual interpretation was 75.8 and 75.4%, respectively, while the negative predictive values were 92.8 and 92.4%, respectively. The accuracy of RDT as interpreted by DR and visually was 82.6 and 82.1%, respectively.
The authors concluded that there was no significant difference in performance of RDTs interpreted by either automated DR or visually by unskilled health workers. However, despite the similarities in performance parameters, the device has proven useful because it provides stepwise guidance on processing RDT, data transfer and reporting. The study was published on May 29, 2018, in the Malaria Journal.
Related Links:
Kilimanjaro Christian Medical University College
Fio Corporation
Rapid diagnostic tests (RDTs) are being advocated and used as alternative, or as an adjunct to microscopy at health facilities because they can be easily used by health workers with less training and equipment, and can be performed by non-specialists in remote settings. The RDTs provide fast test results for initiating or maintaining treatment of patients.
An international team of scientists working with the Kilimanjaro Christian Medical University College (Moshi, Tanzania) recruited a total of 1,293 among 1,423 outpatients with axillary temperature ≥ 37.5 °C, reported fever in the past 24 hours and/or other symptoms suggestive of malaria. The median age for study participants was 21 years and the majority of the participants (71.4%; 923/1293) were aged 18 to 24 years. More than two thirds (69.1%; 893/1293) of study participants were male.
In this study, the SD Bioline Malaria Antigen Pf/pan RDT that detects PfHRP2 (Plasmodium falciparum) and pLDH (pan) was used for malaria diagnosis alongside microscopy. Stained smears were examined by experienced senior microscopists. The Deki Reader (DR, Fio Corporation, Toronto, ON, Canada) provided automated sequential procedures to guide personnel on how to conduct the RDT test. After capturing an image and recognizing the brand of the RDT, the device prompts the user to remove the RDT from the device to proceed with taking blood samples from the patient.
The sensitivity of malaria rapid diagnostic test results interpreted by the Deki Reader was 94.1% and that of visual interpretation was 93.9%. The specificity of malaria rapid diagnostic test results was 71.8% and that of human interpretation was 72.0%. The positive predictive value of malaria RDT results by the Deki Reader and visual interpretation was 75.8 and 75.4%, respectively, while the negative predictive values were 92.8 and 92.4%, respectively. The accuracy of RDT as interpreted by DR and visually was 82.6 and 82.1%, respectively.
The authors concluded that there was no significant difference in performance of RDTs interpreted by either automated DR or visually by unskilled health workers. However, despite the similarities in performance parameters, the device has proven useful because it provides stepwise guidance on processing RDT, data transfer and reporting. The study was published on May 29, 2018, in the Malaria Journal.
Related Links:
Kilimanjaro Christian Medical University College
Fio Corporation
Latest Microbiology News
- Clinical Decision Support Software a Game-Changer in Antimicrobial Resistance Battle
- New CE-Marked Hepatitis Assays to Help Diagnose Infections Earlier
- 1 Hour, Direct-From-Blood Multiplex PCR Test Identifies 95% of Sepsis-Causing Pathogens
- Mouth Bacteria Test Could Predict Colon Cancer Progression
- Unique Metabolic Signature Could Enable Sepsis Diagnosis within One Hour of Blood Collection
- Groundbreaking Diagnostic Platform Provides AST Results With Unprecedented Speed
- Simple Blood Test Combined With Personalized Risk Model Improves Sepsis Diagnosis
- Blood Analysis Predicts Sepsis and Organ Failure in Children
- TB Blood Test Could Detect Millions of Silent Spreaders
- New Blood Test Cuts Diagnosis Time for Nontuberculous Mycobacteria Infections from Months to Hours
- New Tuberculosis Test to Expand Testing Access in Low- and Middle-Income Countries
- Rapid Test Diagnoses Tropical Disease within Hours for Faster Antibiotics Treatment
- Rapid Molecular Testing Enables Faster, More Targeted Antibiotic Treatment for Pneumonia
- Rapid AST Platform Provides Targeted Therapeutic Results Days Faster Than Current Standard of Care
- New Analysis Method Detects Pathogens in Blood Faster and More Accurately by Melting DNA
- Rapid Sepsis Test Delivers Two Days Faster Results