LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Novel Biomarker Identifies Early Clinical CV Disease

By LabMedica International staff writers
Posted on 19 Jul 2017
Print article
Coronary artery disease (CAD) is one of the leading causes of morbidity and mortality worldwide, and the economic, social, and costs associated with treating CAD are very high. The severity of coronary artery lesions has been proven to be associated with the risk of future cardiovascular events.

The role of homocysteine (Hcy) in the pathogenesis of coronary artery disease (CAD) is controversial, as decreased Hcy levels have not demonstrated consistent clinical benefits. Recent studies propose that S-adenosylhomocysteine (SAH), and not Hcy, plays a role in cardiovascular disease (CVD).

Scientists at the Tianjin Medical University General Hospital (Tianjin, China) recruited 160 hospitalized patients with chest pain, aged between 40 and 80 years between March 2016 and September 2016. Patients with atherosclerosis (AS) and CAD were confirmed by coronary angiography. After the patients had fasted overnight, for a minimum of 12 hours, venous blood samples were collected in ethylenediaminetetraacetic acid (EDTA) anticoagulation tubes before coronary angiography.

Plasma Hcy levels were estimated by enzymatic cycling methods. Plasma SAH and S-adenosylmethionine (SAM) concentrations were measured using high performance liquid chromatography (HPLC). The serum folate and serum vitamin B12 concentrations were measured using Immulite Chemiluminescent kits performed on the IMMULITE 2000 XPi analyzer. Levels of total cholesterol, triglycerides, high-density lipoprotein (HDL) cholesterol, creatinine, and fasting blood glucose were measured using routine methods. Low-density lipoprotein (LDL) cholesterol levels were measured using the colorimetric method.

The investigators found that SAH levels were significantly higher in the CAD group (23.09 ± 2.4 nmol/L) than in the AS group (19.2 ± 1.5 nmol/L). While the AS group had higher values for SAM/SAH (5.1 ± 0.7 versus 4.1 ± 1.1), levels of SAM, Hcy, folate, and vitamin B12 were similar in the two groups. Coronary artery lesions were associated with SAH. Plasma SAH concentrations are independently associated with coronary artery lesions among patients undergoing coronary angiography. Plasma SAH might be a novel biomarker for the early clinical identification of CVD.

The authors concluded that that the levels of plasma SAH were independently correlated with coronary lesions among patients undergoing coronary angiography. This positive association suggests that SAH may be a novel and better biomarker for the risk of coronary lesions when compared to Hcy. The study was published on July 4, 2017, in the journal Clinica Chimica Acta.

Related Links:
Tianjin Medical University General Hospital

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more