Biosensor Technology Enables Rapid Detection of Flu Virus
By LabMedica International staff writers Posted on 12 Jun 2017 |
Image: Human influenza virus recognition by sugar-modified conducting polymers. A new conducting polymer was developed for detecting specific interaction of trisaccharide with hemagglutinin in the envelope of the human influenza A virus (H1N1) by electrical manners (Photo courtesy of the Tokyo Medical and Dental University).
A research team has developed a voltage-sensor for early detection of influenza virus A (H1N1) that is almost 100 times more sensitive than conventional tests, and can distinguish between human and avian strains.
Researchers at Tokyo Medical and Dental University (TMDU; Tokyo, Japan) developed the sensor for early detection of even very low virus concentrations. Such early-stage diagnosis is crucial for averting a potential pandemic outbreak, as antiviral medication must be administered in a timely fashion. Conventional tests for detecting the flu virus are often slow and expensive, and can miss early viral infections. In contrast, the new biosensor measures tiny changes in voltage in an electrically conductive polymer to quickly detect virus concentrations almost 100 times smaller than the limit of currently available kits.
Conductive polymers are a class of carbon-based molecules that conduct electricity, but can also be used in biological environments. Biomolecules can be easily attached to the polymers, allowing them to bind with specific targets. In this study, poly(3,4-ethylenedioxythiophene) (PEDOT) was modified with a functional group that binds with the H1N1 human influenza virus, but not avian influenza strains.
“Conducting polymers have several advantages over inorganic counterparts,” explained corresponding author Yuji Miyahara, “These include the ability to conduct both electrical and ionic carriers, mechanical flexibility, low cytotoxicity, low-cost production by casting or printing, and tunable properties via chemical synthesis or doping.”
To construct the biosensor, the polymer film was placed between two electrodes. When a solution containing H1N1, which carries a tiny positive charge on its exterior shell, was added, some of the viruses stuck to the polymer and increased the voltage measured by the electrodes. This electrical method allows the sensor to detect the presence of miniscule amounts of the virus. Viral loads are often measured in hemagglutination units (HAU). The new sensor can detect viral concentrations as small as 0.013 HAU. By comparison, commercially available kits that use immunochromatographic tests only work for concentrations greater than about 1.13 HAU.
“The device is a good candidate for wearable monitoring and point-of-care testing,” added study coauthor Shoji Yamaoka.
The study, by Hai W et al, was published April 5, 2017, in the journal ACS Applied Materials & Interfaces.
Related Links:
Tokyo Medical and Dental University
Researchers at Tokyo Medical and Dental University (TMDU; Tokyo, Japan) developed the sensor for early detection of even very low virus concentrations. Such early-stage diagnosis is crucial for averting a potential pandemic outbreak, as antiviral medication must be administered in a timely fashion. Conventional tests for detecting the flu virus are often slow and expensive, and can miss early viral infections. In contrast, the new biosensor measures tiny changes in voltage in an electrically conductive polymer to quickly detect virus concentrations almost 100 times smaller than the limit of currently available kits.
Conductive polymers are a class of carbon-based molecules that conduct electricity, but can also be used in biological environments. Biomolecules can be easily attached to the polymers, allowing them to bind with specific targets. In this study, poly(3,4-ethylenedioxythiophene) (PEDOT) was modified with a functional group that binds with the H1N1 human influenza virus, but not avian influenza strains.
“Conducting polymers have several advantages over inorganic counterparts,” explained corresponding author Yuji Miyahara, “These include the ability to conduct both electrical and ionic carriers, mechanical flexibility, low cytotoxicity, low-cost production by casting or printing, and tunable properties via chemical synthesis or doping.”
To construct the biosensor, the polymer film was placed between two electrodes. When a solution containing H1N1, which carries a tiny positive charge on its exterior shell, was added, some of the viruses stuck to the polymer and increased the voltage measured by the electrodes. This electrical method allows the sensor to detect the presence of miniscule amounts of the virus. Viral loads are often measured in hemagglutination units (HAU). The new sensor can detect viral concentrations as small as 0.013 HAU. By comparison, commercially available kits that use immunochromatographic tests only work for concentrations greater than about 1.13 HAU.
“The device is a good candidate for wearable monitoring and point-of-care testing,” added study coauthor Shoji Yamaoka.
The study, by Hai W et al, was published April 5, 2017, in the journal ACS Applied Materials & Interfaces.
Related Links:
Tokyo Medical and Dental University
Latest Technology News
- New Diagnostic System Achieves PCR Testing Accuracy
- DNA Biosensor Enables Early Diagnosis of Cervical Cancer
- Self-Heating Microfluidic Devices Can Detect Diseases in Tiny Blood or Fluid Samples
- Breakthrough in Diagnostic Technology Could Make On-The-Spot Testing Widely Accessible
- First of Its Kind Technology Detects Glucose in Human Saliva
- Electrochemical Device Identifies People at Higher Risk for Osteoporosis Using Single Blood Drop
- Novel Noninvasive Test Detects Malaria Infection without Blood Sample
- Portable Optofluidic Sensing Devices Could Simultaneously Perform Variety of Medical Tests
- Point-of-Care Software Solution Helps Manage Disparate POCT Scenarios across Patient Testing Locations
- Electronic Biosensor Detects Biomarkers in Whole Blood Samples without Addition of Reagents
- Breakthrough Test Detects Biological Markers Related to Wider Variety of Cancers
- Rapid POC Sensing Kit to Determine Gut Health from Blood Serum and Stool Samples
- Device Converts Smartphone into Fluorescence Microscope for Just USD 50
- Wi-Fi Enabled Handheld Tube Reader Designed for Easy Portability