Novel Assay Rapidly RSV in Children
By LabMedica International staff writers Posted on 09 May 2017 |
Image: The Alere i RSV assay is designed to easily and rapidly detect respiratory syncytial virus (Photo courtesy of Alere).
A novel rapid assay applies a nicking-enzyme amplification reaction to easily and rapidly detect respiratory syncytial virus (RSV) in children hospitalized with acute respiratory-tract infections.
Respiratory syncytial virus is a common respiratory virus that usually causes mild, cold-like symptoms and most people recover in a week or two, but RSV can be serious, especially for infants and older adults. RSV is the most important cause of acute respiratory-tract infection in neonates and young children.
Scientists at the University Hospital Heidelberg used the novel assay on 117 frozen nasopharyngeal swab samples obtained from children hospitalized with an acute respiratory-tract infection. The median age of the children whose samples were used in this study was 12 months (range: two weeks to 17.7 years).
The team used the Alere i RSV assay and correctly identified all 49 samples positive for RSV. The assay demonstrated 100% sensitivity (95% confidence interval, CI: 93% to 100%), and 97% specificity (95% CI: 89% to 100%). Testing of 65 negative samples confirmed that 63 samples were true negatives; one false-positive was incorrectly identified, and one sample was invalid. Positive test results were called after a median amplification time of 108 seconds (range: 102 to 234 seconds), with results obtained more quickly in samples with high viral load. The test results compared favorably with real-time reverse transcription polymerase chain reaction (RT-PCR) testing.
Sarah Valerie Schnee, a medical student and lead author of the study, “The total test duration, including three minutes for heating the lysis buffer, was five minutes for positive results and 13 minutes for negative results. The availability of sensitive, rapid RSV tests is critical to optimize care management, minimize unnecessary antibiotic use, and provide targeted infection control.” The study was presented at the 27th European Congress of Clinical Microbiology and Infectious Diseases on held April 22-25, 2017, in Vienna, Austria.
Respiratory syncytial virus is a common respiratory virus that usually causes mild, cold-like symptoms and most people recover in a week or two, but RSV can be serious, especially for infants and older adults. RSV is the most important cause of acute respiratory-tract infection in neonates and young children.
Scientists at the University Hospital Heidelberg used the novel assay on 117 frozen nasopharyngeal swab samples obtained from children hospitalized with an acute respiratory-tract infection. The median age of the children whose samples were used in this study was 12 months (range: two weeks to 17.7 years).
The team used the Alere i RSV assay and correctly identified all 49 samples positive for RSV. The assay demonstrated 100% sensitivity (95% confidence interval, CI: 93% to 100%), and 97% specificity (95% CI: 89% to 100%). Testing of 65 negative samples confirmed that 63 samples were true negatives; one false-positive was incorrectly identified, and one sample was invalid. Positive test results were called after a median amplification time of 108 seconds (range: 102 to 234 seconds), with results obtained more quickly in samples with high viral load. The test results compared favorably with real-time reverse transcription polymerase chain reaction (RT-PCR) testing.
Sarah Valerie Schnee, a medical student and lead author of the study, “The total test duration, including three minutes for heating the lysis buffer, was five minutes for positive results and 13 minutes for negative results. The availability of sensitive, rapid RSV tests is critical to optimize care management, minimize unnecessary antibiotic use, and provide targeted infection control.” The study was presented at the 27th European Congress of Clinical Microbiology and Infectious Diseases on held April 22-25, 2017, in Vienna, Austria.
Latest Microbiology News
- New CE-Marked Hepatitis Assays to Help Diagnose Infections Earlier
- 1 Hour, Direct-From-Blood Multiplex PCR Test Identifies 95% of Sepsis-Causing Pathogens
- Mouth Bacteria Test Could Predict Colon Cancer Progression
- Unique Metabolic Signature Could Enable Sepsis Diagnosis within One Hour of Blood Collection
- Groundbreaking Diagnostic Platform Provides AST Results With Unprecedented Speed
- Simple Blood Test Combined With Personalized Risk Model Improves Sepsis Diagnosis
- Blood Analysis Predicts Sepsis and Organ Failure in Children
- TB Blood Test Could Detect Millions of Silent Spreaders
- New Blood Test Cuts Diagnosis Time for Nontuberculous Mycobacteria Infections from Months to Hours
- New Tuberculosis Test to Expand Testing Access in Low- and Middle-Income Countries
- Rapid Test Diagnoses Tropical Disease within Hours for Faster Antibiotics Treatment
- Rapid Molecular Testing Enables Faster, More Targeted Antibiotic Treatment for Pneumonia
- Rapid AST Platform Provides Targeted Therapeutic Results Days Faster Than Current Standard of Care
- New Analysis Method Detects Pathogens in Blood Faster and More Accurately by Melting DNA
- Rapid Sepsis Test Delivers Two Days Faster Results
- Portable Rapid PCR Diagnostic to Detect Gonorrhea and Antibiotic Susceptibility