We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Lab-On-A-Chip Designed to Minimize Preterm Births

By LabMedica International staff writers
Posted on 25 Apr 2017
Print article
Image: Scientists loading the integrated electrokinetically driven microfluidic device with pH-mediated solid-phase extraction coupled to microchip electrophoresis for preterm birth biomarkers (Photo courtesy of Nate Edwards, Brigham Young University).
Image: Scientists loading the integrated electrokinetically driven microfluidic device with pH-mediated solid-phase extraction coupled to microchip electrophoresis for preterm birth biomarkers (Photo courtesy of Nate Edwards, Brigham Young University).
In the USA, a half million babies are born preterm; worldwide, the number is an estimated 15 million and complications associated with preterm birth are the number one cause of death for children under five, and those who live often face a range of health problems.

There presently are no known current biomarker-based diagnostics for preterm births, and doctors typically only pay attention to women who have other clear risk factors. However with the help from a palm-sized plastic rectangle doctors are hoping to minimize the problem of premature deliveries. The chip is designed to predict, with up to 90% accuracy, a woman's risk for a future preterm birth.

Scientists at Brigham Young University have developed a microfluidic device that uses pH-mediated solid phase extraction (SPE) for the enrichment and elution of preterm birth (PTB) biomarkers. Furthermore, this SPE module was integrated with microchip electrophoresis for combined enrichment and separation of multiple analytes, including a PTB peptide biomarker (P1). The team used a reversed-phase octyl methacrylate monolith that was polymerized as the SPE medium in polyethylene glycol diacrylate modified cyclic olefin copolymer microfluidic channels. Eluent for pH-mediated SPE of PTB biomarkers on the monolith was optimized using different pH values and ionic concentrations.

The scientists obtained a nearly 50-fold enrichment that was observed in single channel SPE devices for a low nanomolar solution of P1, with great elution time reproducibility. The monolith binding capacity was determined to be 400 pg (0.2 pmol). A mixture of a model peptide (FA) and a PTB biomarker (P1) was extracted, eluted, injected, and then separated by microchip electrophoresis in our integrated device with approximately 15-fold enrichment.

Adam T. Woolley, PhD, a chemistry professor and senior author of the study, said, “Among other benefits, the device is cheap, small and fast: once fully developed, it will help make detecting biomarkers a simple, automated task. Some peg the annual costs associated with preterm birth just in the USA at close to USD 30 billion, so one clear perk of such a screening tool, is economic. More significantly, there are a lot of preterm babies who don't survive: if we could get them to survive and thrive, it would be a huge gain to society.” The study was published on March 8, 2017, in the journal Electrophoresis.

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The revolutionary autonomous blood draw technology is witnessing growing demands (Photo courtesy of Vitestro)

Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing

Blood drawing is performed billions of times each year worldwide, playing a critical role in diagnostic procedures. Despite its importance, clinical laboratories are dealing with significant staff shortages,... Read more