Paper-Based Battery Powers Microfluidic Devices
By LabMedica International staff writers Posted on 22 Mar 2017 |
Image: A hydraulic battery pumping fluid through a simple microchannel at a constant rate of 0.6 microliters per minute. Each snapshot is 12 minutes apart (Photo courtesy of the University of North Carolina).
A team of biomedical engineers has developed a novel type of "hydraulic battery" that uses inexpensive, minute paper pumps to power the movement of liquids, including biological fluids, through portable microfluidic diagnostic or analytical devices.
Simple fluid pumps have been developed to improve microfluidic device portability, but they could not be easily programmed, produce repeatable pumping performance, or generate complex flow profiles, which are key requirements for increasing the functionality of portable microfluidic devices.
A novel, improved type of fluid pump was recently described by investigators at North Carolina State University and the University of North Carolina. This detachable, paper-based hydraulic battery could be connected to the outlet of a microfluidic channel to pump fluid at varying flow rates over time, including step changes, ramping flows, and oscillating flows.
"Our system uses pieces of paper that are 125 microns thick, little more than the width of a single hair," said senior author Dr. Glenn Walker, associate professor in the joint biomedical engineering program at North Carolina State University and the University of North Carolina. "Capillary action pulls a liquid into the paper, and by changing the shape of the paper, we are able to control how much liquid is pulled through an attached device - and how quickly that happens. By stacking the paper we are able to create more complex flow profiles, depending on the needs for any given application, and any one of these hydraulic battery pumps costs less than a dime. Our hydraulic battery is small, lightweight, very inexpensive, easy to connect to a device, and disposable. In addition, our paper pumps could be saved for later evaluation, such as to run secondary, lab-based tests to confirm on-site diagnoses."
The investigators have filed a patent application to protect the paper pump technology and are currently seeking partners in industry to aid in commercial development.
The hydraulic battery was described in the February 24, 2017, online edition of the journal Technology.
Simple fluid pumps have been developed to improve microfluidic device portability, but they could not be easily programmed, produce repeatable pumping performance, or generate complex flow profiles, which are key requirements for increasing the functionality of portable microfluidic devices.
A novel, improved type of fluid pump was recently described by investigators at North Carolina State University and the University of North Carolina. This detachable, paper-based hydraulic battery could be connected to the outlet of a microfluidic channel to pump fluid at varying flow rates over time, including step changes, ramping flows, and oscillating flows.
"Our system uses pieces of paper that are 125 microns thick, little more than the width of a single hair," said senior author Dr. Glenn Walker, associate professor in the joint biomedical engineering program at North Carolina State University and the University of North Carolina. "Capillary action pulls a liquid into the paper, and by changing the shape of the paper, we are able to control how much liquid is pulled through an attached device - and how quickly that happens. By stacking the paper we are able to create more complex flow profiles, depending on the needs for any given application, and any one of these hydraulic battery pumps costs less than a dime. Our hydraulic battery is small, lightweight, very inexpensive, easy to connect to a device, and disposable. In addition, our paper pumps could be saved for later evaluation, such as to run secondary, lab-based tests to confirm on-site diagnoses."
The investigators have filed a patent application to protect the paper pump technology and are currently seeking partners in industry to aid in commercial development.
The hydraulic battery was described in the February 24, 2017, online edition of the journal Technology.
Latest Technology News
- New Diagnostic System Achieves PCR Testing Accuracy
- DNA Biosensor Enables Early Diagnosis of Cervical Cancer
- Self-Heating Microfluidic Devices Can Detect Diseases in Tiny Blood or Fluid Samples
- Breakthrough in Diagnostic Technology Could Make On-The-Spot Testing Widely Accessible
- First of Its Kind Technology Detects Glucose in Human Saliva
- Electrochemical Device Identifies People at Higher Risk for Osteoporosis Using Single Blood Drop
- Novel Noninvasive Test Detects Malaria Infection without Blood Sample
- Portable Optofluidic Sensing Devices Could Simultaneously Perform Variety of Medical Tests
- Point-of-Care Software Solution Helps Manage Disparate POCT Scenarios across Patient Testing Locations
- Electronic Biosensor Detects Biomarkers in Whole Blood Samples without Addition of Reagents
- Breakthrough Test Detects Biological Markers Related to Wider Variety of Cancers
- Rapid POC Sensing Kit to Determine Gut Health from Blood Serum and Stool Samples
- Device Converts Smartphone into Fluorescence Microscope for Just USD 50
- Wi-Fi Enabled Handheld Tube Reader Designed for Easy Portability