Immunoassay Evaluated for Quantitative Measurement of Fecal α1-Antitrypsin

By LabMedica International staff writers
Posted on 09 Aug 2016
Print article
Image: The SPECTRAmax PLUS plate reader (Photo courtesy of Molecular Devices).
Image: The SPECTRAmax PLUS plate reader (Photo courtesy of Molecular Devices).
The measurement of the protease α1-antitrypsin (A1A) in stool specimens can be used to detect the presence of serum proteins in the gastrointestinal tract a sign of protein-losing enteropathy (PLE).

The major causes of PLE can be divided into erosive and non-erosive gastrointestinal disorders, as well as increased central venous pressure or mesenteric lymphatic obstruction and among such disorders are enteritis, Crohn disease, ulcerative colitis, and celiac disease.

Scientists at the Associated Regional and University Pathologists (ARUP) Laboratories (Salt Lake City, UT, USA) used residual stool specimens sent to ARUP laboratories for fecal A1A testing, as well as paired sera and timed stool samples obtained from healthy volunteers. A1A in stool was measured with a polyclonal antibody-based enzyme-linked immunosorbent assay (ELISA). Assay imprecision, analytical sensitivity, linearity, accuracy, analyte stability, and reference intervals were determined.

Stool A1A was measured by using the Human α1-Antitrypsin ELISA (ImmuChrom, Heppenheim, Germany). This assay is a polyclonal immunometric method used for quantifying the A1A extracted from stool. Signals for ELISA plates were quantified with a SPECTRAmax PLUS plate reader (Molecular Devices LLC, Sunnyvale, CA, USA). Reference intervals for stool A1A and A1A clearance were established using timed stool samples and sera collected from 124 healthy volunteers (62 males, 62 females; ages 19–61 years).

The investigators found that the limit of quantification of the ELISA method used was 2.0 ng/mL, and the assay was linear to 85 ng/mL. The mean recovery of A1A added to samples was 108.2% and A1A was stable in stool for a minimum of two days, seven days, and three months at room temperature, 4 °C to 8 °C and −20 °C, respectively. The upper 95th percentile reference limits for A1A in stool and A1A clearance were 0.48 mg/g and 49 mL/day, respectively.

The authors concluded that the ImmuChrom human A1A ELISA demonstrates acceptable performance characteristics for quantifying A1A in stool extracts. Furthermore, this stool ELISA may be used in combination with the Tina-Quant A1A serum assay (Roche Diagnostics, Basel Switzerland) to assess A1A clearance for diagnosing and monitoring PLE. The study was published in the July 2016 issue of the Journal of Applied Laboratory Medicine.

Related Links:
Associated Regional and University Pathologists Laboratories
ImmuChrom
Molecular Devices
Roche Diagnostics
Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more