Blood Test Detects Chronic Traumatic Encephalopathy During Life
By LabMedica International staff writers Posted on 22 Mar 2016 |
Chronic traumatic encephalopathy (CTE) is a tauopathy associated with prior exposure to repetitive head impacts, such as those incurred through American football and other collision sports and diagnosis is made through neuropathological examination.
A method has been developed for measuring plasma exosomal tau. Exosomes are very small vesicles that are released from all types of cells throughout the body, including brain cells. They can be isolated in all body fluids, including plasma, a component of blood.
Scientists at Boston University School of Medicine (MA, USA) and their colleagues examined 78 former National Football League (NFL) players and a control group of 17 former non-contact sport athletes. Extracellular vesicles were isolated from plasma. Fluorescent nanoparticle tracking analysis was used to determine the number of vesicles staining positive for tau. Blood was drawn by venipuncture and immediately processed. Plasma samples were stored in 0.75 mL tubes at -80 °C, packed in dry ice, and shipped overnight in one batch to the Exosome Sciences laboratory (Monmouth Junction, NJ, USA).
Extracellular vesicles were isolated from the plasma samples by size exclusion chromatography. Plasma samples were applied to the column and it was then run isocratically. The elution was monitored at 280 nm and the void volume material (exosome fraction) was collected and pooled. The size profiles and concentrations of the chromatographically isolated exosomes were performed using the Nanosight LM10 instrument (Malvern Instruments Ltd.; Malvern, UK) equipped with a 405 nm laser, a scientific complementary metal-oxide-semiconductor (sCMOS) camera and Nanoparticle Tracking Analysis (NTA) software.
The method of measuring plasma exosomal tau is referred to as a TauSome. The groups did not differ in total plasma exosomes, but the NFL group had significantly higher plasma exosomal tau than the control group. The C-statistic is maximized when the plasma exosomal tau level is set to 0. Using 0 as a threshold resulted in 82% sensitivity, 100% specificity, 100% positive predictive value and 53% negative predictive value. The number of tau-positive plasma exosomes was significantly correlated with performance on standardized tests of memory and psychomotor speed; the higher the TauSome level, the worse the performance.
Jim Joyce, Founder of Exosome Sciences and Chairman and CEO of Aethlon Medical (San Diego, CA, USA), said, “We are extremely pleased that our initial study data has been published and we appreciate forthcoming opportunities to further advance our TauSome biomarker as a noninvasive solution to detect and monitor CTE in living individuals.” The study was published on February 10, 2016, in the Journal of Alzheimer's Disease.
Related Links:
Boston University School of Medicine
Exosome Sciences
Malvern Instruments Ltd.
A method has been developed for measuring plasma exosomal tau. Exosomes are very small vesicles that are released from all types of cells throughout the body, including brain cells. They can be isolated in all body fluids, including plasma, a component of blood.
Scientists at Boston University School of Medicine (MA, USA) and their colleagues examined 78 former National Football League (NFL) players and a control group of 17 former non-contact sport athletes. Extracellular vesicles were isolated from plasma. Fluorescent nanoparticle tracking analysis was used to determine the number of vesicles staining positive for tau. Blood was drawn by venipuncture and immediately processed. Plasma samples were stored in 0.75 mL tubes at -80 °C, packed in dry ice, and shipped overnight in one batch to the Exosome Sciences laboratory (Monmouth Junction, NJ, USA).
Extracellular vesicles were isolated from the plasma samples by size exclusion chromatography. Plasma samples were applied to the column and it was then run isocratically. The elution was monitored at 280 nm and the void volume material (exosome fraction) was collected and pooled. The size profiles and concentrations of the chromatographically isolated exosomes were performed using the Nanosight LM10 instrument (Malvern Instruments Ltd.; Malvern, UK) equipped with a 405 nm laser, a scientific complementary metal-oxide-semiconductor (sCMOS) camera and Nanoparticle Tracking Analysis (NTA) software.
The method of measuring plasma exosomal tau is referred to as a TauSome. The groups did not differ in total plasma exosomes, but the NFL group had significantly higher plasma exosomal tau than the control group. The C-statistic is maximized when the plasma exosomal tau level is set to 0. Using 0 as a threshold resulted in 82% sensitivity, 100% specificity, 100% positive predictive value and 53% negative predictive value. The number of tau-positive plasma exosomes was significantly correlated with performance on standardized tests of memory and psychomotor speed; the higher the TauSome level, the worse the performance.
Jim Joyce, Founder of Exosome Sciences and Chairman and CEO of Aethlon Medical (San Diego, CA, USA), said, “We are extremely pleased that our initial study data has been published and we appreciate forthcoming opportunities to further advance our TauSome biomarker as a noninvasive solution to detect and monitor CTE in living individuals.” The study was published on February 10, 2016, in the Journal of Alzheimer's Disease.
Related Links:
Boston University School of Medicine
Exosome Sciences
Malvern Instruments Ltd.
Read the full article by registering today, it's FREE!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
- Free digital version edition of LabMedica International sent by email on regular basis
- Free print version of LabMedica International magazine (available only outside USA and Canada).
- Free and unlimited access to back issues of LabMedica International in digital format
- Free LabMedica International Newsletter sent every week containing the latest news
- Free breaking news sent via email
- Free access to Events Calendar
- Free access to LinkXpress new product services
- REGISTRATION IS FREE AND EASY!
Sign in: Registered website members
Sign in: Registered magazine subscribers
Latest Pathology News
- AI Integrated With Optical Imaging Technology Enables Rapid Intraoperative Diagnosis
- HPV Self-Collection Solution Improves Access to Cervical Cancer Testing
- Hyperspectral Dark-Field Microscopy Enables Rapid and Accurate Identification of Cancerous Tissues
- AI Advancements Enable Leap into 3D Pathology
- New Blood Test Device Modeled on Leeches to Help Diagnose Malaria
- Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing
- Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization
- First of Its Kind Universal Tool to Revolutionize Sample Collection for Diagnostic Tests
- AI-Powered Digital Imaging System to Revolutionize Cancer Diagnosis
- New Mycobacterium Tuberculosis Panel to Support Real-Time Surveillance and Combat Antimicrobial Resistance
- New Method Offers Sustainable Approach to Universal Metabolic Cancer Diagnosis
- Spatial Tissue Analysis Identifies Patterns Associated With Ovarian Cancer Relapse
- Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection
- Image-Based AI Shows Promise for Parasite Detection in Digitized Stool Samples
- Deep Learning Powered AI Algorithms Improve Skin Cancer Diagnostic Accuracy
- Microfluidic Device for Cancer Detection Precisely Separates Tumor Entities