New Method Identifies Anthrax Bacteria Faster Than Current Approaches
By LabMedica International staff writers Posted on 06 Mar 2014 |
Caption: The anthrax bacteria – Bacillus anthracis, transmitted mainly through inhalation or skin abrasions (Photo courtesy of University of Missouri).
A new method has been developed for rapid diagnostic detection and antibiotic susceptibility determination of the pathogenic Bacillus anthracis using a bioluminescent reporter phage.
Although anthrax is a treatable disease, positive patient prognosis is dependent on rapid diagnosis and therapy. A team at the University of Missouri (MU; Columbia, MO, USA) assessed a bioluminescent reporter phage, developed by David Schofield at Guild BioSciences (Charleston, SC, USA), for its value as a clinical diagnostic tool for Bacillus anthracis. The reporter phage based method, published in the Journal of Microbiological Methods (November 2013), detects live B. anthracis strains by transducing a bioluminescent phenotype. It was found to rule out false positives – displaying species specificity by its inability, or significantly reduced ability, to detect members of the closely related Bacillus cereus group and other common bacterial pathogens.
The method detects low levels of B. anthracis, at clinically relevant bacterial concentrations, within 5 hours. “Normally to identify whether an organism is present, you have to extract the material, culture it, and then pick colonies to examine that might turn out to be anthrax bacteria,” said Prof. George Stewart, PhD, medical bacteriologist. “Then you conduct chemical testing which takes some time—a minimum of 24 to 48 hours. Using this newly-identified method, we can reduce that time to about 5 hours.” The method also provides antibiotic susceptibility information that mirrors the CLSI method, except that data are obtained at least 5-fold faster.
In addition to saving lives, the new method could also save on high clean up and decontamination costs of bioterrorism attacks. These costs for the post-9/11 2001 anthrax letters attack totaled USD 3.2 million, according to a 2012 report. “In the years since the post-9/11 postal attacks, we haven’t had any bona fide anthrax attacks,” said Prof. Stewart; “That doesn’t mean that it’s not going to happen, we just have to be prepared.” Current methods take 1–3 days to produce definitive results for anthrax. The new detection method would potentially alert of a negative result 5 hours into clean-up efforts instead of 1–3 days into expensive decontamination.
Related Links:
University of Missouri at Columbia
Guild Biosciences
Although anthrax is a treatable disease, positive patient prognosis is dependent on rapid diagnosis and therapy. A team at the University of Missouri (MU; Columbia, MO, USA) assessed a bioluminescent reporter phage, developed by David Schofield at Guild BioSciences (Charleston, SC, USA), for its value as a clinical diagnostic tool for Bacillus anthracis. The reporter phage based method, published in the Journal of Microbiological Methods (November 2013), detects live B. anthracis strains by transducing a bioluminescent phenotype. It was found to rule out false positives – displaying species specificity by its inability, or significantly reduced ability, to detect members of the closely related Bacillus cereus group and other common bacterial pathogens.
The method detects low levels of B. anthracis, at clinically relevant bacterial concentrations, within 5 hours. “Normally to identify whether an organism is present, you have to extract the material, culture it, and then pick colonies to examine that might turn out to be anthrax bacteria,” said Prof. George Stewart, PhD, medical bacteriologist. “Then you conduct chemical testing which takes some time—a minimum of 24 to 48 hours. Using this newly-identified method, we can reduce that time to about 5 hours.” The method also provides antibiotic susceptibility information that mirrors the CLSI method, except that data are obtained at least 5-fold faster.
In addition to saving lives, the new method could also save on high clean up and decontamination costs of bioterrorism attacks. These costs for the post-9/11 2001 anthrax letters attack totaled USD 3.2 million, according to a 2012 report. “In the years since the post-9/11 postal attacks, we haven’t had any bona fide anthrax attacks,” said Prof. Stewart; “That doesn’t mean that it’s not going to happen, we just have to be prepared.” Current methods take 1–3 days to produce definitive results for anthrax. The new detection method would potentially alert of a negative result 5 hours into clean-up efforts instead of 1–3 days into expensive decontamination.
Related Links:
University of Missouri at Columbia
Guild Biosciences
Latest Microbiology News
- New CE-Marked Hepatitis Assays to Help Diagnose Infections Earlier
- 1 Hour, Direct-From-Blood Multiplex PCR Test Identifies 95% of Sepsis-Causing Pathogens
- Mouth Bacteria Test Could Predict Colon Cancer Progression
- Unique Metabolic Signature Could Enable Sepsis Diagnosis within One Hour of Blood Collection
- Groundbreaking Diagnostic Platform Provides AST Results With Unprecedented Speed
- Simple Blood Test Combined With Personalized Risk Model Improves Sepsis Diagnosis
- Blood Analysis Predicts Sepsis and Organ Failure in Children
- TB Blood Test Could Detect Millions of Silent Spreaders
- New Blood Test Cuts Diagnosis Time for Nontuberculous Mycobacteria Infections from Months to Hours
- New Tuberculosis Test to Expand Testing Access in Low- and Middle-Income Countries
- Rapid Test Diagnoses Tropical Disease within Hours for Faster Antibiotics Treatment
- Rapid Molecular Testing Enables Faster, More Targeted Antibiotic Treatment for Pneumonia
- Rapid AST Platform Provides Targeted Therapeutic Results Days Faster Than Current Standard of Care
- New Analysis Method Detects Pathogens in Blood Faster and More Accurately by Melting DNA
- Rapid Sepsis Test Delivers Two Days Faster Results
- Portable Rapid PCR Diagnostic to Detect Gonorrhea and Antibiotic Susceptibility