We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Thromboelastometry Analysis Assessed for Thrombocytopenic Dengue Patients

By LabMedica International staff writers
Posted on 01 Feb 2017
Print article
Image: The rotational thromboelastometry (ROTEM) delta hemostasis analyzer measures kinetic changes of the clot elasticity of whole blood samples (Photo courtesy of ROTEM).
Image: The rotational thromboelastometry (ROTEM) delta hemostasis analyzer measures kinetic changes of the clot elasticity of whole blood samples (Photo courtesy of ROTEM).
Dengue virus infection (DVI) is a prevalent and potentially fatal viral disease associated with coagulopathy. Dengue hemorrhagic fever (DHF) represents a severe clinical presentation of DVI and is characterized by the presence of varying degrees of hemostatic disorders.

Rotational thromboelastometry is a point of care test that promptly provides within 5 to 30 minutes information about the dynamics of clot formation, stabilization and dissolution, reflecting the in vivo hemostasis at the bedside.

Physicians at the Hospital Israelita Albert Einstein conducted a cross-sectional study during a DVI outbreak in São Paulo, Brazil, between April 6 and May 5, 2015. Patients with at least 24 hours of fever (axillary temperature greater than 37.8 °C), in addition to a positive dengue virus (DV) specific immunoglobulin IgM/IgG or non-structural protein-1 (NS1) antigen rapid test and platelet count less than 100 × 109/L were consecutively included in this study.

Rotational Thromboelastometry and the conventional coagulation tests prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (aPTT), thrombin time (TT), platelet count and fibrinogen levels were performed in 53 patients with DVI and thrombocytopenia. Measurement of coagulation in ROTEM was performed after the vertical immersion of a plastic pin into the blood sample. The pin rotates slowly backwards and forwards through an angle of 4.75°. By generation of the first fibrin filaments between the pin and the wall of the test cup, the rotational range of the pin is reduced. The increased restriction of the pin’s movement is transferred to a graphical display, a plot that shows changes in the viscoelastic properties of the clot over time.

The team found that despite a median interquartile range (IQR) platelet count of 77 (63–88) × 109/L in DVI patients, conventional coagulation tests and plasma fibrinogen levels were within the normal range. Subjects demonstrated hypercoagulability in 71.7% (38/53) in intrinsically activated thromboelastometry test (INTEM) and 54.7% (29/53) in extrinsically activated thromboelastometry test (EXTEM) in DVI patients. Fibrin-based thromboelastometry test (FIBTEM) analyses detected only 5.7% (3/53) with hypocoagulability among this population. The median (IQR) clotting time (CT), clot formation time (CFT) and maximum clot firmness (MCF) on INTEM were, respectively, 177 (160–207) seconds, 144 (108–178) seconds and 48 (42–52) mm. On EXTEM, median (IQR) CT, CFT and MCF were, respectively, 69 (65–78) seconds, 148 (126–198) seconds and 49 (44–55) mm.

The authors concluded that thromboelastometry impairment is highly prevalent in DVI patients with thrombocytopenia, particularly in INTEM and EXTEM analyses, while standard coagulation tests are normal in this setting, but clinical implications remain to be established. The study was published on January 19, 2017, in the journal BMC Infectious Diseases.

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Hemoglobin Testing System
VARIANTnbs

Print article

Channels

Clinical Chemistry

view channel
Image: The new ADLM guidance will help healthcare professionals navigate respiratory virus testing in a post-COVID world (Photo courtesy of 123RF)

New ADLM Guidance Provides Expert Recommendations on Clinical Testing For Respiratory Viral Infections

Respiratory tract infections, predominantly caused by viral pathogens, are a common reason for healthcare visits. Accurate and swift diagnosis of these infections is essential for optimal patient management.... Read more

Molecular Diagnostics

view channel
Image: Molecular PCR-grade detection of Lyme bacteria right at the tick bite (Photo courtesy of En Carta Diagnostics)

Groundbreaking Molecular Diagnostic Kit to Provide Lyme Disease Detection in Minutes

Lyme disease, transmitted through tick bites, is a bacteria-caused illness that impacts 1.2 million individuals annually. The standard methods for diagnosing this disease include clinical examinations,... Read more

Immunology

view channel
Image: The novel test uses an existing diagnostic procedure as its basis to target the Epstein Barr Virus (Photo courtesy of 123RF)

Blood Test Measures Immune Response to Epstein-Barr Virus in MS Patients

Multiple sclerosis (MS) is a chronic neurological condition for which there is currently no cure. It affects around three million people globally and ranks as the second most common cause of disability... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more

Pathology

view channel
Image: Insulin proteins clumping together (Photo courtesy of Jacob Kæstel-Hansen)

AI Tool Detects Tiny Protein Clumps in Microscopy Images in Real-Time

Over 55 million individuals worldwide suffer from dementia-related diseases like Alzheimer's and Parkinson's. These conditions are caused by the clumping together of the smallest building blocks in the... Read more

Industry

view channel
Image: For 46 years, Roche and Hitachi have collaborated to deliver innovative diagnostic solutions (Photo courtesy of Roche)

Roche and Hitachi High-Tech Extend 46-Year Partnership for Breakthroughs in Diagnostic Testing

Roche (Basel, Switzerland) and Hitachi High-Tech (Tokyo, Japan) have renewed their collaboration agreement, committing to a further 10 years of partnership. This extension brings together their long-standing... Read more