Высокочувствительный анализ на основе микрожидкостной хроматографии и тандемной масс-спектрометрии разработан для определения эстрадиола в сыворотке крови

By LabMedica International staff writers
Posted on 12 Aug 2016
Система Eksigent Ekspert micro LC 200 для выполнения микрожидкостной хроматографии (фото любезно предоставлено компанией Sciex).
Система Eksigent Ekspert micro LC 200 для выполнения микрожидкостной хроматографии (фото любезно предоставлено компанией Sciex).
Существуют ощутимые потребности в точном измерении низких концентраций эстрадиола (E2), составляющих менее 20 пг/мл, у женщин в постменопаузальный период, мужчин, пациентов детского возраста и пациентов, проходящих лечение рака молочной железы.

Автоматизированные методы иммунологического анализа являются наиболее широко используемыми методами для измерений E2 в клинических лабораториях; однако им недостает точности и точности измерения при низких физиологических концентрациях E2. На основе микрожидкостной хроматографии – тандемной масс-спектрометрии (micro LC-MS/MS) был разработан высокочувствительный метод без дериватизации, чтобы достоверно измерять концентрации E2 ниже 5 пг/мл с использованием небольшого объема пробы.

Ученые из Чикагского университета (штат Иллинойс, США) использовали образцы для сравнения методов из оставшихся образцов, доставленных из лаборатории клинической химии. В общей сложности 290 мкл образца было смешано с внутренним стандартом, E2-d4, и извлечено со смесью гексана/этилацетата (процентное соотношение объёмов 90/10). После извлечения образец был отделен с помощью системы Eksigent Ekspert micro LC 200 с расходом жидкости, равным 35 мкл/мин. при полном времени пробега, равном 3.5 минут, и обнаружен с помощью масс-спектрометра QTRAP 6500 (Sciex, Фрамингем, штат Массачусетс, США) в режиме отрицательной ионизации, используя переходы: 271/145 (квантификатор) и 271/143 (квалификатор). В этом методе было крайне важно использовать колонки для проведения жидкостной хроматографии высокого давления, имеющие стабильность при pH >10.

Измерения E2, выполненные с помощью микрожидкостной хроматографии и тандемной масс-спектрометрии, сравнили с автоматизированным методом иммунологического анализа Cobas 8000 E2 II (компания Roche Diagnostics, Базель, Швейцария), используя 42 образца плазмы крови, собранных в пробирки с литий-гепарином, и с разработанным в лаборатории непрямым радиоиммунологическим анализом, используя 38 образцов сыворотки крови, собранных в обычные сывороточные пробирки. Метод микрожидкостной хроматографии и тандемной масс-спектрометрии показал хорошую корреляцию с радиоиммунологическим анализом и невысокую корреляцию с автоматизированным методом иммунологического анализа E2 Roche Cobas. Валидационное исследование показало широкие линейные диапазоны от 3.0 до 820 пг/мл. Итоговая точность измерений была ниже 15% на всех уровнях контроля качества, и нижняя граница определяемых концентраций составляла 3.0 пг/мл. Исследование было опубликовано в выпуске журнала Journal of Applied Laboratory Medicine за июль 2016 года.

Ссылки по теме:
University of Chicago
Sciex
Roche Diagnostics


Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
Neonatal Heel Incision Device
Tenderfoot
New
Gold Member
Serum Indices Control
Acusera Serum Indices Control
New
Fully Automated Urinalysis System
DxU 1800 Fully Automated Urinalysis System

Channels

Clinical Chemistry

view channel
Image Credit: Shutterstock

Blood Test Could Guide Drug Selection to Prevent Repeat Heart Attacks and Strokes

Secondary prevention after myocardial infarction or stroke relies on antiplatelet therapy, yet responses vary widely and both recurrent thrombosis and bleeding remain persistent risks. In the United Kingdom,... Read more

Molecular Diagnostics

view channel
Image: The Avantect Pancreatic Cancer Test combines epigenomic, genomic, and glycan biomarkers with machine learning to detect pancreatic cancer-associated signals in blood (Photo courtesy of ClearNote Health)

Multiomic Blood Test Supports Noninvasive Monitoring and Subtyping in Pancreatic Cancer

Pancreatic ductal adenocarcinoma remains difficult to detect early and monitor during treatment, particularly in patients with homologous recombination defects. Clinicians also have limited noninvasive... Read more

Immunology

view channel
Image: Although many people harbor latent Epstein-Barr virus (EBV), growing evidence has linked the virus to MS pathobiology (Image Credit: Adobe Stock)

Blood EBV Activity Biomarkers May Predict Multiple Sclerosis Relapse Months Ahead

Predicting relapse in multiple sclerosis (MS) remains difficult, limiting opportunities for timely intervention and monitoring. Although many people harbor latent Epstein-Barr virus (EBV), growing evidence... Read more

Microbiology

view channel
Image: Graphical Abstract (Jose A. Céspedes, Maria I. Montañez, Isabel M. Jiménez, et al. Magnetic nanoparticles enable clinically relevant in vitro diagnosis of beta-lactam allergy. Materials Today Bio (2026). DOI: 10.1016/j.mtbio.2026.103356)

Magnetic Nanoparticles Enable More Sensitive Beta-Lactam Allergy Testing

Penicillin allergy labels are common in clinical practice, yet many are incorrect and can lead to suboptimal antibiotic choices. Although 8%–25% of people report a penicillin allergy, only 1%–10% are truly... Read more

Pathology

view channel
Image: A new study demonstrates that vascular features in colorectal tumors could serve as prognostic biomarkers of disease outcome. (Image Credit: iStock)

Tumor Blood Vessel Features May Help Predict Colorectal Cancer Survival

Colorectal cancer outcomes vary widely, and tumor biology remains a key determinant of prognosis. Because neoplasms depend on a vascular supply, differences in intratumoral vessels may influence survival.... Read more

Technology

view channel
Image: ADLM recommends that emerging AI tools follow the same professional oversight, quality, validation, and monitoring standards as traditional clinical testing within CLIA’s existing framework (Image Credit: Adobe Stock)

ADLM Calls for CLIA Updates to Support Safe AI Use in Laboratory Medicine

Clinical laboratories increasingly use artificial intelligence to verify, interpret, and report results, but safeguards under the Clinical Laboratory Improvement Amendments (CLIA) were designed in 1992.... Read more

Industry

view channel
Image Credit: Adobe Stock

Mayo Clinic and Thermo Fisher Launch Multi-Omics Venture to Identify Early Disease Signals

Many diseases begin developing years before symptoms emerge, making early detection difficult for healthcare systems and clinical laboratories. Linking molecular changes with longitudinal health data could... Read more