We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Rapid Diagnostic Tests Compared for Benign Tertian Malaria

By LabMedica International staff writers
Posted on 04 Aug 2014
Print article
Image: Photomicrograph of a thin film blood smear reveals the presence of two Plasmodium vivax schizonts, an immature form on the left, and a mature form on the right (Photo courtesy of Dr. Mae Melvin).
Image: Photomicrograph of a thin film blood smear reveals the presence of two Plasmodium vivax schizonts, an immature form on the left, and a mature form on the right (Photo courtesy of Dr. Mae Melvin).
The standard method for malaria diagnosis is by the routine microscopic examination of Giemsa-stained blood smears and rapid diagnostic tests (RDTs) that detect malaria parasite proteins by immunochromatography which have been used as complementary detection method for malaria diagnosis.

Recent advances in the development of species-specific RDTs, such as the Plasmodium vivax aldolase-specific test, will greatly enhance the quality of testing and reduce over-administration of anti-malarial drugs in endemic areas to a more species-specific approach to the treatment of malaria.

Scientists at the South China University of Technology (Guangzhou, China) examined slides from 77 P. vivax-positive blood samples and 33 non-P. vivax samples were collected from patients in the Yunnan province of China. Non-P. vivax samples included 31 P. falciparum and 2 P. malariae samples. Healthy blood samples were randomly collected from 423 volunteers in Guangzhou.

Three commercially available Plasmodium lactate dehydrogenase (LDH) or aldolase antigen detection kits were evaluated with P. vivax positive as well as non-P. vivax samples and healthy samples using blood smear examination as standard. The RDTs tested were the One Step Malaria P.f/P.v (Guangzhou Wondfo Biotech; China), the ParaHit Total (Span Diagnostics Ltd.; Surat, India), the SD Bioline Malaria (Standard Diagnostics; Yongin, South Korea), and an in-house anti-P. vivax aldolase-specific monoclonal antibody (mAb) pair 1C3-12 F10.


The mAb 1C3-12 F10 pair targeting P. vivax-specific aldolase exhibited very good specificity and sensitivity of 100% and 97.4%, respectively. The anti-P. vivax LDH in the One-Step Malaria P.f/P.v test showed sensitivity of 93.5%, and a specificity of 98.0%. The ParaHit Total targeting the pan-aldolase antigen showed a sensitivity of 97.4%, and a specificity of 99.6%. The SD Bioline had sensitivity of 93.5%, and a specificity of 100%. The overall sensitivity and specificity of all four RDTs were acceptable, especially for the aldolase detection tests. Five of the P. vivax-positive samples that were confirmed by microscopic examination as well as the two aldolase detection RDTs were undetected by the two LDH detection RDTs. Two positive samples that were positively confirmed by the LDH detection RDTs were also undetected by the aldolase detection test kits.

The authors concluded that aldolase and LDH antigens perform differently in different P. vivax samples and therefore there is a high risk of misdiagnosis when monoclonal antibodies are used against only one particular antigen in the test. A combination of both aldolase and LDH in RDTs for the rapid diagnosis of P. vivax will enhance the sensitivity of the assay and reduce misdiagnosis. The estimated global burden of malaria due to P. vivax is approximately 70 to 80 million cases annually. The study was published on July 11, 2014, in the Malaria Journal.

Related Links:

South China University of Technology
Guangzhou Wondfo Biotech
Span Diagnostics Ltd.



Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The new ADLM guidance will help healthcare professionals navigate respiratory virus testing in a post-COVID world (Photo courtesy of 123RF)

New ADLM Guidance Provides Expert Recommendations on Clinical Testing For Respiratory Viral Infections

Respiratory tract infections, predominantly caused by viral pathogens, are a common reason for healthcare visits. Accurate and swift diagnosis of these infections is essential for optimal patient management.... Read more

Molecular Diagnostics

view channel
Image: Molecular PCR-grade detection of Lyme bacteria right at the tick bite (Photo courtesy of En Carta Diagnostics)

Groundbreaking Molecular Diagnostic Kit to Provide Lyme Disease Detection in Minutes

Lyme disease, transmitted through tick bites, is a bacteria-caused illness that impacts 1.2 million individuals annually. The standard methods for diagnosing this disease include clinical examinations,... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The novel test uses an existing diagnostic procedure as its basis to target the Epstein Barr Virus (Photo courtesy of 123RF)

Blood Test Measures Immune Response to Epstein-Barr Virus in MS Patients

Multiple sclerosis (MS) is a chronic neurological condition for which there is currently no cure. It affects around three million people globally and ranks as the second most common cause of disability... Read more

Pathology

view channel
Image: Insulin proteins clumping together (Photo courtesy of Jacob Kæstel-Hansen)

AI Tool Detects Tiny Protein Clumps in Microscopy Images in Real-Time

Over 55 million individuals worldwide suffer from dementia-related diseases like Alzheimer's and Parkinson's. These conditions are caused by the clumping together of the smallest building blocks in the... Read more

Industry

view channel
Image: For 46 years, Roche and Hitachi have collaborated to deliver innovative diagnostic solutions (Photo courtesy of Roche)

Roche and Hitachi High-Tech Extend 46-Year Partnership for Breakthroughs in Diagnostic Testing

Roche (Basel, Switzerland) and Hitachi High-Tech (Tokyo, Japan) have renewed their collaboration agreement, committing to a further 10 years of partnership. This extension brings together their long-standing... Read more