We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

P-O-C Assay Detects Respiratory Syncytial Virus in Older Adults

By LabMedica International staff writers
Posted on 22 Feb 2022
Print article
Image: The Xpert Xpress Flu/RSV Assay is intended as an aid in the diagnosis of influenza and respiratory syncytial virus infections (Photo courtesy of Cepheid)
Image: The Xpert Xpress Flu/RSV Assay is intended as an aid in the diagnosis of influenza and respiratory syncytial virus infections (Photo courtesy of Cepheid)

The point-of-care Xpert Xpress Flu/RSV test appeared nearly as accurate as routine real-time RT-PCR for detecting respiratory syncytial virus (RSV) infections in older adults, a Dutch study found.

Lower respiratory tract infections are estimated to be the fifth-leading cause of mortality worldwide. Respiratory syncytial virus (RSV) is a major cause of respiratory infections in older adults (≥60 years) with a substantial disease burden.

Currently, the gold standard for RSV diagnosis is laboratory-based real-time reverse-transcription polymerase chain reaction (RT-PCR). RT-PCR has the disadvantage that it requires technical skills and has a long turnaround time. Therefore, reliable rapid diagnostic tests are needed to improve patient management, to enable cohorting and isolation of hospitalized patients, to prevent unnecessary use of antibiotics.

Pediatric Immunology and Infectious Disease Specialists at the University Medical Centre Utrecht (Utrecht, The Netherlands) and their international colleagues collected 758 respiratory samples from 561 older adults at a median of 4 days after symptom onset, from two consecutive RSV seasons. Participants were recruited from 17 general practices before the start of each RSV season. A little more than half of participants were women (54%), the median age was 75, and about 38% had comorbidities Two nasopharyngeal minitip flocked swabs (FLOQSwab, Copan Diagnostics, Brescia, Italy) were collected by a member of the study team and directly stored in universal transport medium.

The team compared the performance of the Xpert® Xpress Flu/RSV assay (Cepheid, Sunnyvale, CA, USA) with real-time reverse-transcription polymerase chain reaction (RT-PCR) in the home-dwelling older adults. For the Xpert Xpress Flu/RSV assay, the cartridge was opened and the entire content of the filled pipette was slowly expelled into the cartridge. Subsequently, the cartridge was inserted into the GeneXpert System. After approximately 30 minutes, test results were available on the screen. For RT-PCR, an in-house–developed kit was used. RSV-A and -B were detected and quantified by duplex RT-PCR using specific amplification primers and fluorescent probes designed to detect the RSV N gene.

The scientists reported that 35 (4.6%) samples tested positive for RSV by at least one of the assays, of which two samples were negative by Xpert Xpress Flu/RSV and three samples by real-time RT-PCR. The positive percentage agreement (PPA) was 90.9% (95% confidence interval [CI], 76.4%–96.8%) and negative percentage agreement was 99.7% (95% CI, 99.0%–99.9%). Viral loads were low (≤103 copies/mL or cycle threshold value ≥34) in all cases with discordant results for the two assays.

The authors concluded that they had performed the first international prospective community-based study to compare the performance of a rapid molecular detection test for RSV infection with RT-PCR in home-dwelling older adults. They demonstrated that the PPA and overall rate of agreement between Xpert Xpress Flu/RSV and routine RSV RT-PCR for RSV detection in home-dwelling older adults is high. The assay is fast and easy to use and therefore has the ability to improve patient management and outcomes. The study was published on February 4, 2022 in The Journal of Infectious Diseases.

Related Links:
University Medical Centre Utrecht 
Copan Diagnostics
Cepheid 

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A network of inflammatory molecules may act as biomarker for risk of future cerebrovascular disease (Photo courtesy of 123RF)

Simple Blood Test Could Enable First Quantitative Assessments for Future Cerebrovascular Disease

Cerebral small vessel disease is a common cause of stroke and cognitive decline, particularly in the elderly. Presently, assessing the risk for cerebral vascular diseases involves using a mix of diagnostic... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more