Pulmonary Embolism Diagnosed by Improved Interpretation of Blood Tests
By LabMedica International staff writers Posted on 10 Dec 2019 |
Image: Diazyme`s D-Dimer Assay is a highly sensitive liquid stable latex enhanced immunoturbidimetric test kit, designed to work on most open clinical chemistry analyzers to provide rapid results with reduced reagent cost (Photo courtesy of Diazyme Laboratories)
Pulmonary embolism is the sudden blockage of a major blood vessel (artery) in the lung, usually by a blood clot. In most cases, the clots are small and are not deadly, but they can damage the lung and if the clot is large and stops blood flow to the lung, it can be deadly.
D-dimer is a fibrin degradation product (or FDP), a small protein fragment present in the blood after a blood clot is degraded by fibrinolysis. It is so named because it contains two D fragments of the fibrin protein joined by a cross-link. A new way to interpret blood test results in patients who are investigated for blood clots in their lungs, and this new approach applies to D-dimer blood tests, which are used by physicians to rule out the presence of a blood clot.
Scientists working with the Hamilton Health Sciences (Hamilton, ON, Canada) enrolled a total of 2,017 patients aged 18 and older who were evaluated in a study, of which 7% had pulmonary embolism on initial diagnostic testing. The average age of the patients was 52 years, and 66% were female. Of the patients in the study, 1,474 (73%) were enrolled at Hamilton Health Sciences or St. Joseph's Healthcare Hamilton. These patients, and those at other university-based clinical centers in Canada, were tested from December 2015 through May 2018 and assessed 90 days later.
The team reported that of the 1,325 patients identified by an emergency department physician as having a low (1,285 of the patients) or a moderate (40 patients) probability of having a pulmonary embolism and who had negative D-dimer results (that is, less than 1,000 or 500 ng/mL, respectively), none had venous thromboembolism during follow-up.
Clive Kearon, MB, MRCPI, FRCPC, PhD, a professor of medicine, and a senior author of the study, said, “The primary goal of diagnostic testing for pulmonary embolism is to identify which patients should be treated with anticoagulant agents and which should not. When a physician is concerned that pulmonary embolism may be present, chest imaging with CT pulmonary angiography is usually done in half of these patients. We wanted to find a way to reduce the number of CT scans that need to be done. Our analyses show that pulmonary embolism is ruled out by a D-dimer level of less than 1,000 ng/mL in patients with a low probability, and by a D-dimer level of less than 500 ng/mL in patients with a moderate probability. This way of using D-dimer testing and clinical assessment reduced the need for CT scanning by one-third.” The study was published on the November 28, 2019 in the New England Journal of Medicine.
Related Links:
Hamilton Health Sciences
D-dimer is a fibrin degradation product (or FDP), a small protein fragment present in the blood after a blood clot is degraded by fibrinolysis. It is so named because it contains two D fragments of the fibrin protein joined by a cross-link. A new way to interpret blood test results in patients who are investigated for blood clots in their lungs, and this new approach applies to D-dimer blood tests, which are used by physicians to rule out the presence of a blood clot.
Scientists working with the Hamilton Health Sciences (Hamilton, ON, Canada) enrolled a total of 2,017 patients aged 18 and older who were evaluated in a study, of which 7% had pulmonary embolism on initial diagnostic testing. The average age of the patients was 52 years, and 66% were female. Of the patients in the study, 1,474 (73%) were enrolled at Hamilton Health Sciences or St. Joseph's Healthcare Hamilton. These patients, and those at other university-based clinical centers in Canada, were tested from December 2015 through May 2018 and assessed 90 days later.
The team reported that of the 1,325 patients identified by an emergency department physician as having a low (1,285 of the patients) or a moderate (40 patients) probability of having a pulmonary embolism and who had negative D-dimer results (that is, less than 1,000 or 500 ng/mL, respectively), none had venous thromboembolism during follow-up.
Clive Kearon, MB, MRCPI, FRCPC, PhD, a professor of medicine, and a senior author of the study, said, “The primary goal of diagnostic testing for pulmonary embolism is to identify which patients should be treated with anticoagulant agents and which should not. When a physician is concerned that pulmonary embolism may be present, chest imaging with CT pulmonary angiography is usually done in half of these patients. We wanted to find a way to reduce the number of CT scans that need to be done. Our analyses show that pulmonary embolism is ruled out by a D-dimer level of less than 1,000 ng/mL in patients with a low probability, and by a D-dimer level of less than 500 ng/mL in patients with a moderate probability. This way of using D-dimer testing and clinical assessment reduced the need for CT scanning by one-third.” The study was published on the November 28, 2019 in the New England Journal of Medicine.
Related Links:
Hamilton Health Sciences
Latest Pathology News
- Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing
- Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization
- First of Its Kind Universal Tool to Revolutionize Sample Collection for Diagnostic Tests
- AI-Powered Digital Imaging System to Revolutionize Cancer Diagnosis
- New Mycobacterium Tuberculosis Panel to Support Real-Time Surveillance and Combat Antimicrobial Resistance
- New Method Offers Sustainable Approach to Universal Metabolic Cancer Diagnosis
- Spatial Tissue Analysis Identifies Patterns Associated With Ovarian Cancer Relapse
- Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection
- Image-Based AI Shows Promise for Parasite Detection in Digitized Stool Samples
- Deep Learning Powered AI Algorithms Improve Skin Cancer Diagnostic Accuracy
- Microfluidic Device for Cancer Detection Precisely Separates Tumor Entities
- Virtual Skin Biopsy Determines Presence of Cancerous Cells
- AI Detects Viable Tumor Cells for Accurate Bone Cancer Prognoses Post Chemotherapy
- First Ever Technique Identifies Single Cancer Cells in Blood for Targeted Treatments
- Innovative Blood Collection Device Overcomes Common Obstacles Related to Phlebotomy
- Intra-Operative POC Device Distinguishes Between Benign and Malignant Ovarian Cysts within 15 Minutes