We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Phoenix CPO Test Evaluated for Detection of Carbapenemase Producers

By LabMedica International staff writers
Posted on 14 Nov 2019
Print article
Image: The BD Phoenix CPO detect test will allow hospitals to identify infections caused by carbapenemase-producing organisms (CPOs) (Photo courtesy of Becton-Dickinson).
Image: The BD Phoenix CPO detect test will allow hospitals to identify infections caused by carbapenemase-producing organisms (CPOs) (Photo courtesy of Becton-Dickinson).
The use of nucleic acid amplification tests (NAAT) to identify rapidly Carbapenemase-Producing Organisms (CPO) from samples such as positive blood culture and stools is an alternative approach to establish rapidly an optimal empirical antibiotic therapy or for infectious control management.

Most carbapenemase NAAT panels detect the most frequent gene variants encoding for carbapenemases including KPC, NDM, OXA-48, VIM and IMP. However, these tests cannot exclude the presence of a gene encoding another carbapenemase type and are relatively expensive, hence preventing their use to screen systematically some specimen types or bacterial isolates with CPO suspicion, especially in low to very low prevalence countries.

Medical microbiologists at the Lausanne University Hospital (Lausanne, Switzerland) tested the performance of the Phoenix CPO Detect Test (Becton-Dickinson, Franklin Lakes, NJ, USA) on a collection of 92 molecularly-characterized CPO and 93 non-CPO. The collection included 27 non-fermentative bacteria and 158 Enterobacterales. In addition, 295 clinical isolates, including 135 isolates with suspected carbapenemase, were prospectively, but not consecutively isolated from various de-identified clinical specimens during a 10 months period ranging from January to October 2018.

MALDI-TOF was used as an additional phenotypic test to exclude the presence of carbapenemase activity in Phoenix CPO Detect test false positives. All false positive results of the Phoenix CPO Detect test from the prospective study were verified by NAAT testing using the BD MAX Check-Points CPO test. Whole genome sequencing and analysis with libraries prepared with the Nextera XT kit (Illumina, San Diego, USA).

In a retrospective study the scientists reported the Phoenix CPO test exhibited 92.4% accuracy, 97.8% sensitivity 87.1% specificity for carbapenemase detection. The Phoenix CPO test provided a classification to class A, B, and D for 81.3% of detected carbapenemases with 94.6% accuracy. In a prospective study, the CPO test detection performance showed 77.8% accuracy, 100% sensitivity and 67.8% specificity on 135 CPO suspicious isolates and 98.8% accuracy and specificity on 160 non-CPO suspicious isolates. Compared to routine testing, the implementation of the CPO test allowed a mean reduction of 21.3 hours in turnaround time (TAT), 16.8 minutes) in hands-on time (HOT), and CHF 20.6 in costs.

The authors concluded that the Phoenix CPO Detect test likely represents a new diagnostic tool with added value for the detection and management of CPO infection and colonization. The CPO test is reliable for the detection of CPO with a high sensitivity but the relatively low specificity requires the use of additional confirmatory methods. The carbapenemase classification accuracy is robust to provide preliminary results before molecular characterization. The study was published on October 18, 2019 in the journal Clinical Microbiology and Infection.

Related Links:
Lausanne University Hospital
Becton-Dickinson
Illumina


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: The fastGEN BCR::ABL1 Cancer kit offers a way to personalize treatment strategies for leukemia (Photo courtesy of BioVendor MDx)

First of Its Kind NGS Assay for Precise Detection of BCR::ABL1 Fusion Gene to Enable Personalized Leukemia Treatment

The BCR::ABL1 fusion gene plays a key role in the pathogenesis of several blood cancers, particularly chronic myeloid leukemia (CML). This gene results from a chromosomal translocation that causes constitutive... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The new method is quick and easy, and can also be used by non-medical personnel. (Photo courtesy of Zoratto et al. Advanced Science 2024, edited)

New Blood Test Device Modeled on Leeches to Help Diagnose Malaria

Many individuals have a fear of needles, making the experience of having blood drawn from their arm particularly distressing. An alternative method involves taking blood from the fingertip or earlobe,... Read more